Rinnai REU V2632FFU Скачать руководство пользователя страница 9

Flueing Installation Instructions 

 

Rinnai Australia Pty Ltd     20/08/2003 

 

 

Page 9  of  10

  

 

 

Components Page

 

UP

UP

UP

765

65

975

5

15

100

5

5

15

775

275

15

FFWALLTERM

FFROOFCOWL

FFPIPE1000

FFCONDK

FFADAPT

125

80

125

80

125

80

85

85

85

225

215

125

127

210

15

125

80

83

5

15

FFBEND45

80

116

85

62.5

5

12.5

22

UP

FFBEND90

FFWSEAL

FFWPLATE

5

15

80

85

UP

FFBEND90BA

5

83

1050

Tickness 1mm

Tickness 2mm

25

25

5

85

163

136

UP

116

136

170

 

 
 

FFU Flue Part Numbers 

 

 

DESCRIPTION 

CODE NUMBER 

BAR CODE NUMBER 

Vertical Adaptor 

FFADAPT 

9314109107692 

Elbow 90 Degrees Bend Adaptor 

FFBEND90BA 

9314109107654 

Elbow 45 Degrees (2 in Box) 

FFBEND45 

9314109107067 

Elbow 90 Degrees 

FFBEND90 

9314109107647 

Condensate Trap 

FFCONDK 

9314109107708 

Flue Pipe 1000mm length 

FFPIPE1000 

9314109107061 

Horizontal Flue Terminal 

FFWALLTERM 

9314109107685 

Vertical Flue Terminal 

FFROOFCOWL 

9314109107678 

Ceiling Ring 

FFWSEAL 

9314109107722 

Wall Plate 

FFWPLATE 

9314109107715 

 

 

 

 

Содержание REU V2632FFU

Страница 1: ...ly installed Water Heater Models REU V2632FFU REU V2632FFUC UP UP UP This Flue shall be installed in accordance with Manufacturer s Installation Instructions Local Gas Fitting Regulations Municipal Bu...

Страница 2: ...el single skin or stainless steel coaxial flue If in doubt contact the Rinnai Australia Technical Advice Helpline 1300 366 388 2 Before commencing installation please read the Installation Instruction...

Страница 3: ...rrs and file a slight bevel on the outer edge to reduce any damage to the seal when inserting into the connecting fitting See the section Cutting the Flue Components Fig 9 127mm Hole FFWALLTERM UP FFB...

Страница 4: ...length of the horizontal terminal and cut to length allowing for the outer section of the flue to extend 10mm through the wall See the section cutting flue components Fig 9 6 From outside the building...

Страница 5: ...e length can be up to 9 metres long and a maximum of 3 bends can be used 2 All vertical installations start with the vertical adaptor This MUST be connected with the larger end Black outer seal facing...

Страница 6: ...the requirements of AS5601 AG601 Clause 5 13 6 2 Fig 5 3 5 If the total length of the flue exceeds 1 5 meters a condensate trap MUST be installed either vertically or horizontally adjacent to the heat...

Страница 7: ...ing the dimensions shown on page 9 calculate the required number and combination of extension pieces and bends to be connected between the Infinity unit and terminal cut the appropriate components to...

Страница 8: ...m the condensate trap connection point to the point of discharge or tundish outside the building There must be no tap valve or any other restrictions in the condensate drain and the tundish MUST NOT b...

Страница 9: ...0 Tickness 1mm Tickness 2mm 25 25 5 85 163 136 UP 116 136 170 FFU Flue Part Numbers DESCRIPTION CODE NUMBER BAR CODE NUMBER Vertical Adaptor FFADAPT 9314109107692 Elbow 90 Degrees Bend Adaptor FFBEND9...

Страница 10: ...any other opening into a building with the exception of sub floor ventilation Space heaters up to 50 MJ h input 150 Other appliances up to 50 MJ h input 500 Appliances over 50 MJ h input and up to 15...

Отзывы: