Flueing Installation Instructions 

 

Rinnai Australia Pty Ltd     20/08/2003 

 

 

Page 5  of  10

  

 

2. 

Using the dimensions shown in 

(Fig. 7) 

calculate the required number and combination of extension pieces 

and bends to be connected between the Infinity unit and wall terminal. Cut each length as required. (See the 
section cutting flue components 

(Fig.9).

 

3. 

Connect the 90º bend adaptor onto the heater flue spigot in the direction required. The arrow on the side of 
the bend will face the in the direction of flue discharge. 

4. 

Drill a 135mm hole for the flue terminal (Cover the flue spigot to avoid debris from entering the appliance). 

5. 

From outside the building, fit the wall plate to the flue terminal and place through the hole in the wall. 

6. 

From inside the building fit a wall plate (if required) onto the flue. 

7. 

Repeat steps 4 and 5 for all internal wall penetrations.  

8. 

Secure the extension pieces between the flue terminal and 90º adaptor bend, ensuring a 2

°

 fall to outside.  

9. 

Ensure the flue is totally supported with the brackets supplied in each length of flue pipe. 

10. 

Adjust the heater to the required distance from the wall and tighten the hanging bracket securing screws. 

11. 

Secure the decorative wall plates with the terminal in the sloped down position and secure to inner and outer 
walls. 

 

12. 

Seal between the flue and the wall plates using silicon sealant.

 

 

3. Vertical Straight Flueing With Roof Terminal 
 

1. 

This option can be used when the water heater needs to be flued vertically through the roof. The Rinnai Infinity 
'Vertical Flueing Components' with extension pieces and condensate trap (if necessary) is used for this 
purpose. The 'Vertical Flueing Components' consists of a Flue terminal and vertical adaptor. If the total flue 
height is less than 1.5 metres, a condensate trap is not required. For installations over 1.5 metres a 
condensate trap is required. 

(Fig.3)

 

Total flue length can be up to 9 metres long and a maximum of 3 

bends can be used.   

2. 

All vertical installations start with the vertical adaptor. This MUST be connected with the larger end (Black 
outer seal) facing down on the appliance 

3. 

Ensure there is enough space to install the Infinity, flue assembly and pipe work. Check the roof space for any 
flue obstructions. Also ensure that positioning of the vertical flue terminal complies with the requirements of 
AS5601/AG601 

Clause 5.13.6.2

 / 

Fig.5.3. 

 

Installation 

 

1. 

Using the dimensions provided in 

(Fig.7)

 Install the REU-V2632FFU/REU-V2632FFUC water heater as per the 

installation instructions located in the pocket on the back of the front heater cover. 

2. 

Fit the vertical adaptor and condensate trap (if required) onto the water heater. 

3. 

Set plumb bob from the centre of the heater flue outlet to ceiling marking position. Cut 127mm hole in 
plasterboard (or suitable 'oval' for pitched roof). Repeat this step for underside of roofing. 

4. 

Calculate the required number and combination of extension pieces and cut to length as

 required (See the 

section cutting flue components 

(Fig.9)

 

5. 

Install flue and terminal. Flue to terminate at least 500mm from the end of the flue to the nearest part of the 
roof. (AS5601/AG601 clause 1 5.13.6.2) see 

(Fig.3)

. Seal the roof penetration with an approved flashing. 

6. 

Install ceiling ring. (Not supplied, if required Rinnai Part No. FFWSEAL). 

7. 

Ensure the flue is fully supported independently of the appliance, by the use of suitable clips or brackets, as per 
AS5601/AG601 clause 5.13.4.2 and 5.13.4.3. 

8. 

Ensure that the appliance can be removed without causing movement or displacement of the flue, as per 
AS5601/AG601 clause 5.13.4.1.  This can be achieved if a 100mm distance is kept between the gas and water 
isolating valves and the connection points at the water heater 

(Fig.5).

 

9. 

Ensure the condensate trap outlet (if fitted) is drained in accordance with the requirements of AS3500.4.2 
clause 4.12. 

10. 

All external outer plastic joints should be glued with approved cement to prevent water entering the flue.

 

Содержание REU V2632FFU

Страница 1: ...ly installed Water Heater Models REU V2632FFU REU V2632FFUC UP UP UP This Flue shall be installed in accordance with Manufacturer s Installation Instructions Local Gas Fitting Regulations Municipal Bu...

Страница 2: ...el single skin or stainless steel coaxial flue If in doubt contact the Rinnai Australia Technical Advice Helpline 1300 366 388 2 Before commencing installation please read the Installation Instruction...

Страница 3: ...rrs and file a slight bevel on the outer edge to reduce any damage to the seal when inserting into the connecting fitting See the section Cutting the Flue Components Fig 9 127mm Hole FFWALLTERM UP FFB...

Страница 4: ...length of the horizontal terminal and cut to length allowing for the outer section of the flue to extend 10mm through the wall See the section cutting flue components Fig 9 6 From outside the building...

Страница 5: ...e length can be up to 9 metres long and a maximum of 3 bends can be used 2 All vertical installations start with the vertical adaptor This MUST be connected with the larger end Black outer seal facing...

Страница 6: ...the requirements of AS5601 AG601 Clause 5 13 6 2 Fig 5 3 5 If the total length of the flue exceeds 1 5 meters a condensate trap MUST be installed either vertically or horizontally adjacent to the heat...

Страница 7: ...ing the dimensions shown on page 9 calculate the required number and combination of extension pieces and bends to be connected between the Infinity unit and terminal cut the appropriate components to...

Страница 8: ...m the condensate trap connection point to the point of discharge or tundish outside the building There must be no tap valve or any other restrictions in the condensate drain and the tundish MUST NOT b...

Страница 9: ...0 Tickness 1mm Tickness 2mm 25 25 5 85 163 136 UP 116 136 170 FFU Flue Part Numbers DESCRIPTION CODE NUMBER BAR CODE NUMBER Vertical Adaptor FFADAPT 9314109107692 Elbow 90 Degrees Bend Adaptor FFBEND9...

Страница 10: ...any other opening into a building with the exception of sub floor ventilation Space heaters up to 50 MJ h input 150 Other appliances up to 50 MJ h input 500 Appliances over 50 MJ h input and up to 15...

Отзывы: