GAS PRESSURE SETTING
9. Adjust pressure setting to the
minimum value
(Tab. 1 below)
adjusting screw on modulating
valve (Fig.6).
10. Change nr. 5 and nr. 6 switch on PCB to ON
position (Fig.5) to force appliance to high
forced combustion and open all hot water taps
(
CAUTION: advise users not to use water
).
11. Adjust pressure setting to the
maximum value
(Tab. 2 below)
adjusting screw on PCB
(Fig.7).
12. Set nr. 5 and nr. 6 switch on PCB to OFF position (Fig.5) for normal combustion and
close taps.
13. Isolate gas supply and cut off power supply.
14. Remove digital manometer and set pressure point screw with o
-
ring (Fig. 4).
15. Connect gas and check for gas leakages.
16. Connect operating controller connector (Fig. 2).
17. Set front cover (2 screws) (Fig. 1) and connect power.
MAX GAS
Continuum 11i (11i-fp) Continuum 14i (14i-fp)
NG
G20
G230
7.45
8.50
6.90
LPG
G30
G31
11.58
9.47
(pressures in mbar) - Tab. 2
MIN GAS
Continuum 11i (11i-fp) Continuum 14i (14i-fp)
NG
G20
G230
0.80
0.80
1.57
LPG
G30
G31
2.21
0.90
(pressures in mbar) - Tab. 1
Adjustment Point
Fig. 7
Adjustment Point
Fig. 6
Содержание REU-1110FFU(F)-E
Страница 8: ...8 OPERATION...
Страница 17: ...17 MAIN COMPONENTS...
Страница 29: ...29 DIMENSIONS...
Страница 32: ...32 FLOW CHART...
Страница 33: ...33 WIRING DIAGRAM REU 1110FFU E REU 1110FFU F E...
Страница 35: ...35 WATER FLOW CHARACTERISTICS REU 1110FFU E REU 1110FFU F E...
Страница 36: ...36 LETTER OF COMPLIANCE...
Страница 37: ...37 CE CERTIFICATE...
Страница 39: ...39 COMMISSIONING CHECK LIST COMMISSIONING SHEET...
Страница 40: ...40 SERVICE RECORD...