Rinnai Tankless Water Heater Installation and Operation Manual
53
5.7.1 ThermaCirc360™ Recirculation (Determine
Recirculation Mode)
Two recirculation modes are available:
DEDICATED MODE
CROSSOVER MODE
Cold Water
Hot Water
Dedicated mode
(factory default)
- Home
includes a dedicated circulation return line
in the plumbing system. The water heater
is shipped configured for the Dedicated
Recirculation Line mode.
Crossover mode - Home does not include a
dedicated circulation return line. Requires
installation of a thermal bypass valve
(purchased separately) at the furthest
fixture in the plumbing system.
General Guidelines
•
For the licensed installer / professional
•
For installation in commercial and residen
-
tial domestic hot water applications only.
•
Rinnai strongly recommends installing
insulation to the hot water and dedicated
return lines to decrease the amount of
heat loss.
•
DO NOT install in combination with
hydronic heating applications.
•
DO NOT electronically manifold (EZ
-
Connect™) multiple REP units together.
•
MSB and Cascade accessories are not
compatible with REP models.
•
DO NOT install the MC-195T-US Timer/
Controller and control•r™ Wi-Fi Module
together as they are not compatible
accessories.
Figure 80
Figure 81