CAUTION
20
Rinnai Tankless Water Heater Installation and Operation Manual
4.3.6 Clearances
Top
Side
Bottom
Bottom
Front
Front
Figure 9: Clearances
Table 7: Clearances
Indoor (internal) units
Outdoor (external) units
Top
Side
If clearances are not met, damage to the property and water heater may occur.
Location
Clearances To Combustibles
and Non-Combustibles
Top
2 in. (51 mm)
Bottom/Ground
12 in. (305 mm)
Front (Panel)
0 in.
The clearance for servicing is
24 inches in front of the water
heater.
Do not block the combustion air
openings.
Back
0 in.
Sides
(Left and Right)
2 in. (51 mm)
0.125 in. (3.18 mm) for recess
box.
Front (Exhaust)
24 in. (610 mm)
Location
Clearances To Combustibles
and Non-Combustibles
Top
2 in. (51 mm)
0 in. from vent components
Bottom/Ground
12 in. (305 mm)
Front (Panel)
0 in.
The clearance for servicing is 24
inches (610 mm) in front of the
water heater.
For closet installation, clearance is
6 inches (152 mm) from the front
of the water heater.
Back
0 in.
Sides
(Left and Right)
2 in. (51 mm)
Vent
0 in.
Do not install this water heater under an overhang less
than 3 ft. (91.4 cm) from its top. The area under the
overhang must be open on three sides.
Indoor units
Outdoor units