background image

WIRING DIAGRAM

13

ELECTRICAL SPECIFICATION

388 x 222 x 129 mm

1.45 kg (No Pump)
1.80 kg (DC Pump)

ELECTRICAL LOADING

Min. WATER FLOW RATE

Min. INL ET WATER PRESSURE

Max. INLET WATER PRESSURE

WATER CONNECTION

DIMENSIONS

NET WEIGHT

TYPE

ELECTRICAL POWER CONTROL

3.8kW    240V a.c.    50/60Hz

2 Litre / min

0.2 Bar (20kPa)

6 Bar (0.6MPa)

1/2” BSP SINGLE POINT SYSTEM

Note: The specification, actual product’s cosmetic design and accessories parts
               shown are correct at the time of printing and may be subjected to change
               without prior notice.

GROSS WEIGHT

2.20 kg (No Pump) - Bracket Accessories
2.55 kg (DC Pump) - Bracket Accessories
2.50 kg (No Pump) - Slider Rail Accessories
2.85 kg (DC Pump) - Slider Rail Accessories

Содержание REI-E380NP-B-WH

Страница 1: ...47301 Petaling Jaya Selangor Darul Ehsan Malaysia Toll Free 1800 88 8180 Fax Email customercare rinnai com my Web www rinnai com my 03 7832 0036 Instructions for use installation and connection MODEL...

Страница 2: ...ets 1 x Sliding Rail 1 x Shower Holder 2 x Rail Supports Wall Brackets 1 x PVC hose 1 5m 3 x Washers Shower rail accessories PART CONTENTS CHECKLIST MODEL 1 x Stop Valve 1 x Mesh Filter 1 x Handshower...

Страница 3: ...e it may cause damage to the pump motor 1 5 The appliance is not intended for use by person including children with reduced physical sensory or mental capabilities or lack of experience and knowledge...

Страница 4: ...screw points of the Shower Holder beside the Instant Hot Shower It is recommended that the top of the portion is in level with the top of Heater Unit 2 Use 6mm diameter drill and make the wall plug ho...

Страница 5: ...g Rail Shower Holder and adjust to your ideal position 7 Check if any water leakage 8 Do not use white tape during piping installation Fig 4 7 8 PROCEDURE 1 Insert the wall embedded cable through Side...

Страница 6: ...VARIABLE SWITCH 1 Turn on the water supply and Stop Valve the water will flow through the Handshower 2 Switch on the electrical supply 3 Turn the Temperature Control to ON the Red Indicator HEATER wil...

Страница 7: ...p valve The water pressure remain unstable Adjust the water pressure A The filter is obstructed by sediments A Clean the filter B The shower head is clogged A Clean the shower head A Shower head is bl...

Страница 8: ...OWER CONTROL 3 8kW 240V a c 50 60Hz 2 Litre min 0 2 Bar 20kPa 6 Bar 0 6MPa 1 2 BSP SINGLE POINT SYSTEM Note The specification actual product s cosmetic design and accessories parts shown are correct a...