TEST THE ‘ELCB’ REGULARLY
(This procedure is highly recommended to test at least once a
month)
Turn on the electricity and water supply, both Red (HEATER) and
Green (ELCB) Indicators will light up if the Temperature Control
Knob is at ‘ON’ position. Press the ELCB Test Button, both HEATER
and ELCB Indicators should go off. Press the Reset Button to
resume the electricity supply.
Read the section ‘ SAFETY INFORMATION ’ first.
CLEANING PRECAUTIONS!
Do not use thinner, alcohol, petrol or any other organic solutions to
clean the set. Use only damped cloth with mild detergent.
CLEAN THE FILTER REGULARLY (Fig. 8 & Fig. 9)
3.
CLOSE
OPEN
INTERNAL
STRAINER
OPEN
CLOSE
FLOW REGULATOR
MESH FILTER
BUILT-IN FILTER
If the Indicator does not change from RED to BLUE when you press the ELCB Test Button, switch
OFF the mains supply and contact your sales agent for repair. Special skill is required
for repair. NEVER TRY TO REPAIR THE UNIT BY YOURSELF.
MAINTENANCE
1.
2.
1.
WARNING !
FILTER UNIT
CLEANING
Fig. 9
Fig. 8
Clean the Mesh Filter regularly to prevent blockage. Remove the
Built-In Filter by turning its cap anticlockwise. Whenever is needed,
flush the internal strainer with water to remove any trapped
sediments.
Whenever fixing back the Built-In Filter, beware of the alignment of
internal Strainer. Use the protruded guideline within Stop Valve to
position the Internal Strainer.
TABLE 1 - ELECTRICAL LOADING TABLE
TEST RUN
mm²
2.5
10.4
2.5
20
20
3.3
13.8
2.5
20
20
3.6
15.0
2.5
20
20
4.0
16.7
2.5
20
20
5.0
20.8
4.0
32
32
3.8
15.8
4.0
20
20
2.4
10.9
2.5
20
20
3.5
15.9
2.5
20
20
4.5
20.5
2.5
32
32
5.5
25.0
4.0
32
32
6.0
27.3
4.0
32
32
7 / 0.85 mm
50 / 0.25 mm
56 / 0.25 mm
56 / 0.25 mm
56 / 0.30 mm
56 / 0.30 mm
220~
50/60Hz
7 / 0.67 mm
7 / 0.67 mm
7 / 0.67 mm
7 / 0.85 mm
230~
50/60Hz
7 / 0.85 mm
50 / 0.25 mm
50 / 0.25 mm
50 / 0.25 mm
56 / 0.25 mm
56 / 0.30 mm
56 / 0.30 mm
On/Off
Switch (A)
Fuse/
MCB (A)
240~
50/60Hz
7 / 0.67 mm
7 / 0.67 mm
7 / 0.67 mm
7 / 0.67 mm
7 / 0.85 mm
Voltage
(AC)
Power
(kW)
Current
(A)
Conduit Cable
Flexible Cable
Minimum Conductor Size (csa)
Malaysia
Model
Fig. 6
PUMP
VARIABLE
SWITCH
1. Turn on the water supply and Stop Valve, the water will flow through the Handshower.
2. Switch on the electrical supply.
3. Turn the Temperature Control to ‘ ON’ , the Red Indicator (HEATER) will light on, hot water will flow out
within few seconds. The more Temperature Control Knob being turned clockwise direction, the hotter
water inflow in order to get the desired showering temperature.
4. The shower might not be hot enough even at the ‘ MAX’ position if incoming water supply from the mains
is too cold or the pressure of water is too high. In this case, you may adjust the Stop Valve to reduce the
water inflow in order to get the desired showering temperature.
5. Check the Built-in ELCB as following:
- Press the “ TEST ” Button, the Built-in ELCB should trip and cut off the power supply, all LED
Indicator should light off except BLUE LED remain on.
- Press the “RESET ” Button, the Heater Unit should resume normal function, the Green LED
Indicator should light on.
If procedure stated above prevailed, the ELCB is functioning normal condition.
6. The height and direction of Shower Holder are adjustable. Adjustment can be done by pressing the
holder knob and sliding the Shower Holder simultaneously to desired position.
7. Move the Handshower to desired angle. A ratched mechanism in the Shower Holder will hold the
Handshower in selected position. (Fig. 6)
8. Switch OFF the electricity supply after shower.
9. For Pump Models:
Turn on the Pump Control Knob to test on Pump’s functionality (located at side). If the shower is not hot
enough, you may adjust the pump speed until the desired shower temperature is obtained. (Fig.6)
3.3
14.4
2.5
20
20
4.0
17.4
2.5
20
20
5.0
21.8
4.0
32
32
50 / 0.25 mm
56 / 0.25 mm
56 / 0.30 mm
7 / 0.67 mm
7 / 0.67 mm
7 / 0.85 mm
Singapore
Model
2.4
10.4
2.5
20
20
3.0
13.0
2.5
20
20
50 / 0.25 mm
50 / 0.25 mm
7 / 0.67 mm
7 / 0.67 mm
This Innovative adjustable Handshower has different spray patterns. (Fig. 7)
The patterns are described as following:
Clean the Handshower Head holes by using the soft brush from time to time.
(Recommended once a week)
Note: Take care not to damage the holes of the Handshower Head during cleaning.
HANDSHOWER SPRAY
Fig. 7
Bracket Handshower Spray Patterns
Slider Rail Handshower Spray Patterns