INBUILT INSTALLATION, MASONRY FIRE PLACE
8. INSTALL THE HEATER
•
Feed the copper tube through the supply access
opening.
•
Connect and tighten gas supply union.
•
Secure heater to fireplace, there are pre-drilled
holes in the heater flanges.
•
Drill additional holes if the existing ones are not in
suitable positions.
9. INSTALL RADIANTS
•
Remove glass panel, install radiants as shown.
•
Replace glass panel.
10. CHECK FOR GAS ESCAPES
•
Use a manometer or soapy water.
•
DO NOT
USE A NAKED FLAME.
11. CLOSE GAS SUPPLY COVER
•
This seals the heater from the chimney and prevents
chimney draughts affecting the performance of the
heater, as well as preventing the entry of debris from
the chimney.
12. INSTALL COWL
•
A cowl certified for gas appliances must be installed
on all chimneys.
•
Clearances to conform with AS/NZS 5601. The
minimum clearance between top of chimney and
the lowest opening in the flue cowl is 200 mm as
shown.
•
Size:100 mm.
13. TEST APPLIANCE
•
See page 26.
14. INSTRUCT CUSTOMER
•
Instruct customer on operation and servicing of the
appliance.
•
Remind customer of dress guard requirements.