Ultima II Installation Manual
INBUILT INSTALLATION, MASONRY FIRE PLACE
1. CHECK DIMENSIONS OF FIREPLACE
Masonry Fireplace Dimensions
Width
710 mm minimum
805 mm maximum
Height
605 mm minimum
635 mm maximum
Depth
330 mm minimum
2. CHECK FLUEWAY
•
Remove damper plate/baffle - Any damper plate or
baffle which has been installed in the chimney shall
be removed.
•
Check flueway is clear of obstructions.
•
Check dimensions of fireplace and if necessary
remove any protruding brickwork to give 75 mm
minimum clearance from flue spigot.
•
Provide a firm, flat and sealed base for heater. A
rough base may cause rattles and affect
performance.
•
Check that there are no unwanted holes or
openings in fireplace. If so these must be sealed.
•
The chimney must be confirmed free of soot and
creosote that may have built up if previously used
for a solid fuel fire. Before installing the heater,
inspect the chimney, flue piping and/or solid fuel
burning fire place and remove any combustible
materials.
•
A gas appliance must not be connected to a
chimney flue serving a separate solid-fuel burning
appliance.
•
Peel protective backing off the foam strips supplied
with the heater.
•
Attach strips supplied with the heater. The strip is
intended to form a seal between the heater and
fireplace. If an adequate seal cannot be formed
with this strip another means of sealing must be
used (e.g. fibreglass batts), between the fireplace
and the heater body.
3. FIT FLUE SPIGOT
•
The flue spigot is packed separately in the carton.
•
It must be fitted to all models, inbuilt and console.
4. GAS INLET UNION
•
For ease of connection a combined gas inlet union/
copper elbow is provided with every heater. It is
situated at the bottom right hand side below the
control.
w
d
h
w
h
d