background image

3.6 (91)

14 (355.6)

9.6 (244.5)

22

.9

 (

5

82)

2

5

.5 (

6

48

.2

)

4.3 (110)

1.1 (27)

3.5 (89)

3.9 (99)

2.8 (70)

R75LSi (VA2528FFUD)    

Rinnai Corporation

 • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us 

Water Temperature Control 

Controller 

 
 
 
 
Controller Cable 

Safety Devices 
 
 
 

Clearances from Combustibles 
(suitable for closet, attic, and 
crawl space installations) 

Clearances from Non-combustibles 

 
 
Min. / Max.  Gas Supply Pressure 

 
Manifold Gas Pressure (inches W.C.) 

 
NOx 

Warranty 

Simulation feed forward and feedback 

MC-91-1US (part of the front panel) 
Deluxe controller: MC-100V-1US (optional) 
Bathroom controller: BC-100V-1US (optional) 
Wireless controller: MC-502RC-1US-MS (optional) 
MCC-91-1US (for commercial applications) 

Non-polarized two-core cable, minimum 22 AWG 

• 

Flame failure - Flame Rod 

• 

Boiling protection 

• 

Combustion fan rpm check 

• 

Over current - glass fuse (3 amp) 

• 

Top of heater - 6 inches 

• 

Front of heater - 6 inches 

• 

Sides of heater - 2 inches 

• 

Top of heater - 2 inches 

• 

Front of heater - 6 inches 

• 

Sides of heater - 1/2 inch 

Natural Gas:  min 5”  W.C. 

max 10.5”  W.C. 

Propane Gas:  min 8”  W.C. 

max 13.5”  W.C. 

Natural Gas:  high fire 2.7”  W.C. 

low fire 0.52”  W.C.  

Propane Gas:  high fire 4.4”  W.C.  

low fire 0.92”  W.C. 

Meets California and Texas NOx Emission Rules 

Heat exchanger: 12 years* for residential and 5 years* for 
commercial and hydronic applications; (10 years* if used with the 
Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year; 
(* 3 years if used as a circulating water heater within a circulation 
loop, when the water heater is in series with a circulation system 
and all circulating water flows through the water heater) 

DIMENSIONS 

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior 
notice. Local, state, provincial and federal codes must be adhered to prior to installation. 

• 

Remaining flame (OHS) 

• 

Thermal fuse 

• 

Automatic frost protection 

 

• 

Back of heater - 0 inches 

• 

Bottom of heater - 12 inches 

• 

From vent pipe - 0 inches 

• 

Back of heater - 0 inches 

• 

Bottom of heater - 12 inches 

• 

From vent pipe - 0 inches 

The wall bracket is adjustable to allow 
an additional 1.57 inches (40 mm). 

in (mm) 

WEIGHT: 50 LBS (23 KG)

 