3.6 (91)
14 (355.6)
9.6 (244.5)
22
.9
(
5
82)
2
5
.5 (
6
48
.2
)
4.3 (110)
1.1 (27)
3.5 (89)
3.9 (99)
2.8 (70)
R75LSi (VA2528FFUD)
Rinnai Corporation
• 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
Water Temperature Control
Controller
Controller Cable
Safety Devices
Clearances from Combustibles
(suitable for closet, attic, and
crawl space installations)
Clearances from Non-combustibles
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx
Warranty
Simulation feed forward and feedback
MC-91-1US (part of the front panel)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
Wireless controller: MC-502RC-1US-MS (optional)
MCC-91-1US (for commercial applications)
Non-polarized two-core cable, minimum 22 AWG
•
Flame failure - Flame Rod
•
Boiling protection
•
Combustion fan rpm check
•
Over current - glass fuse (3 amp)
•
Top of heater - 6 inches
•
Front of heater - 6 inches
•
Sides of heater - 2 inches
•
Top of heater - 2 inches
•
Front of heater - 6 inches
•
Sides of heater - 1/2 inch
Natural Gas: min 5” W.C.
max 10.5” W.C.
Propane Gas: min 8” W.C.
max 13.5” W.C.
Natural Gas: high fire 2.7” W.C.
low fire 0.52” W.C.
Propane Gas: high fire 4.4” W.C.
low fire 0.92” W.C.
Meets California and Texas NOx Emission Rules
Heat exchanger: 12 years* for residential and 5 years* for
commercial and hydronic applications; (10 years* if used with the
Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year;
(* 3 years if used as a circulating water heater within a circulation
loop, when the water heater is in series with a circulation system
and all circulating water flows through the water heater)
DIMENSIONS
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
•
Remaining flame (OHS)
•
Thermal fuse
•
Automatic frost protection
•
Back of heater - 0 inches
•
Bottom of heater - 12 inches
•
From vent pipe - 0 inches
•
Back of heater - 0 inches
•
Bottom of heater - 12 inches
•
From vent pipe - 0 inches
The wall bracket is adjustable to allow
an additional 1.57 inches (40 mm).
in (mm)
WEIGHT: 50 LBS (23 KG)