Check the items below before contacting Rinnai for service� Service and parts charges may be incurred where it 

is found that there is no fault with the water heater and the issue is related to the plumbing installation or is due to 

the failure of water or electric supplies�

Insufficientornohotwater

Is the electricity supply 

connected?

Check that the isolating switch marked “HOT WATER” or “WATER HEATER” at the 

meter box is switched on� Check also that any isolating switches installed near the 

water heater are switched on�
Check the fuse or circuit breaker marked “HOT WATER” or “WATER HEATER” at 

the meter box� Repeated failure of fuse or tripping of circuit breaker indicates a fault 

which must be investigated by an authorised trades person�

Are you using more hot 

water than you think?

Often it is not realised how much hot water is actually used� This applies especially 

to showering. Review hot water usage, especially the time taken for showering, and 

investigate the use of flow control valves or water saving shower roses.

Are water heater valves 

discharging excessively?

Refer to the section “Safety Devices” on page 7�

Thermostat settings?

Check the temperature of hot water delivered with a thermometer placed under the 

closest outlet (usually the kitchen sink) on a non-tempered hot water line�
This test should be done early in the morning after overnight electrical boosting 

before any hot water is used� The temperature of the water delivered should be at 

least 55°C (allowing for heat losses in pipe work)�

If this is not the case, the temperature may need to be increased. Contact Rinnai to 

discuss adjusting the thermostat�

No water from the hot tap? Restriction in the hot tap or failure of the cold water supply to the heater�

Check for water flow at the other hot taps and that the cold water isolation valve is 

fully open�

Highelectricitybills

If you think your electricity 

bill  is  too  high,  check  for 

these possibilities�

If, after investigating, and 

you still require assistance 

contact Rinnai.

You may be using more hot water than you think� This applies especially to showering� 

Review hot water usage, especially the time taken for showering, and investigate the 

use of flow control valves or ‘water saving’ shower roses. Investigate recent changes 

to hot water usage patterns�
Water heater valves may be discharging excessively� Refer to the section “Safety 

Devices” on page 7�
There may be hot water leakages in hot water pipes or taps� Have these checked 

and rectified by a qualified person.
There may have been changes in electricity tariffs since your last bill.

PERIODIC MAINTENANCE & SERVICING

If overflow tray and drain are fitted, it is the users responsibility to have these checked periodically to ensure there 

are no blockages�

The user should operate the easing gear of the ECV and PTR valve (if fitted) every 6 months as described under 

“Safety Devices” on page 7�

Rinnai service network personnel are fully trained and equipped. If your Rinnai appliance requires servicing contact 

Rinnai as per the details on the back page of this manual� Rinnai recommends that this commercial appliance be 

inspected and serviced by a qualified person every 12 months.

The ECV and PTR valve 

MUSTBE

 checked for performance or replaced by a qualified person at intervals not 

exceeding 5 years or more frequently in areas where the water is classified as scaling water (refer to “Water 

Quality” on page 8 for details)�

If the electric supply conduit to the water heater is damaged, it 

MUSTBE

 replaced only by a authorised person in 

order to avoid a hazard�

CARE & MAINTENANCE

Содержание QRESS315L336

Страница 1: ...Quick Recovery Electric QRE Operation Installation Manual Models QRESS80L336 QRESS80L348 QRESS315L336 QRESS315L348 QRESS315L360...

Страница 2: ...3000 AS NZS 3500 4 Local Regulations and Municipal Building Codes including local OH S requirements This appliance must be installed maintained and removed by an Authorised Person For continued safet...

Страница 3: ...Dimensions 11 Table 2 Ratings Other Specifications 11 Installation Configurations 12 Hot Water Plumbing System Example Multiple Installation 12 Hot Water Plumbing System Example No TLD 13 Hot Water Pl...

Страница 4: ...TR Valve 17 Expansion Control Valve ECV 17 Pressure Limiting Valve PLV 17 Relief Valve Drain Lines 17 Electrical Connections 18 Commissioning 19 Wiring Diagram 80L 19 Wiring Diagram 315L 20 To fill tu...

Страница 5: ...le materials near this appliance This appliance is NOT suitable for use as a spa pool or swimming pool heater WARNING NOTICE TO VICTORIAN CONSUMERS This appliance MUST BE installed by a person license...

Страница 6: ...is too hot Always Test the temperature of the water with your elbow before placing your child in the bath also carefully feel water before bathing or showering yourself Supervise children whenever th...

Страница 7: ...son It is normal for the PTR valve to release a small quantity of water through the drain pipe during heating If the valve dribbles or leaks continuously try easing the valve gear for a few seconds Th...

Страница 8: ...ds and a volume of water sufficient for daily usage is heated during the set period and stored The Off Peak supply is usually cheaper Electricity supply types and tariffs vary according to the local e...

Страница 9: ...riction in the hot tap or failure of the cold water supply to the heater Check for water flow at the other hot taps and that the cold water isolation valve is fully open High electricity bills If you...

Страница 10: ...t 3 6kW Includes Gasket 80 or 315 L 95110046 Element 4 8kW Includes Gasket 10003735 Element 6 0kW Includes Gasket 315 L only 10003743 3 Terminal Block 80 or 315 L 26401708 4 Thermostat R SH ADJ 60 80...

Страница 11: ...A Cylinder Rated Pressure kPa PTR Valve Rated Pressure kPa ECV Rated Pressure kPa ECV Fitted Fit PLV if mains pressure exceeds kPa Recommended PLV pressure rating kPa QRESS315L336 3 6 15 850 850 700...

Страница 12: ...equal length and plumbed see example figure above to ensure pressure drops are balanced For multiple systems and tanks ensure the connecting pipework is configured to balance system pressure drop B B...

Страница 13: ...ating Valve Isolating Valve PLV ECV OR WATER HEATER Non return Valve COLD SUPPLY Non return Valve Non return Valve WATER HEATER Temperature Limiting Device TLD Non return Valve PTR VALVE Supplied TO D...

Страница 14: ...RETURN PIPE WORK WITH TLD COLD SUPPLY Isolating Valve ECV TO DRAIN Non return Valve PLV KITCHEN LAUNDRY NON TEMPERED SUPPLY BATHROOM ENSUITE TO DRAIN PTR VALVE Supplied WATER HEATER Not Supplied Non r...

Страница 15: ...result of water leakage the water heater MUST BE installed with a safe tray overflow tray and drain Construction installation and draining of the safe tray MUST comply with local regulatory requiremen...

Страница 16: ...Installation Configurations WARNING Valves with pressure ratings other than specified MUST NOT be used An isolation valve and non return valve MUST BE fitted in the cold water supply to the water hea...

Страница 17: ...ve outlet in accordance with the section Relief Valve Drain Lines on the bottom of page 17 The valve body MUST BE insulated in accordance with local regulatory requirements and AS NZS 3500 4 to optimi...

Страница 18: ...cal cable connections to the water heater Electrical cable entry to the water heater is via a 25mm hole provided beneath the front cover fitting of an approved M25 weatherproof cable gland at the elec...

Страница 19: ...Single Number of Throws Single Dial Colour Pink Temp Range 60 to 80 C Dial Set At 70 C Cut Off 60 C 3 Differential 8 C 4 Reset Manual 3 1 4 5 2 ST1205113 RESET 3 1 4 5 2 ST1205113 RESET 3 1 4 5 2 ST12...

Страница 20: ...3 RESET 3 1 4 5 2 ST1205113 RESET L1 L2 L3 N 1 2 3 Active Neutral Active Active Neutral Earth Neutral Thermostat Specifications ST1205113 Number of Poles Single Number of Throws Single Dial Colour Pin...

Страница 21: ...now be forced out of the taps 3 Close each tap when water runs freely without air bubbles 4 Check all plumbing connections and pipe work for water leaks 5 Connect the water heater to the electricity s...

Страница 22: ...Rinnai 22 SS QRE HW IM NOTES...

Страница 23: ...Rinnai 23 SS QRE HW IM NOTES...

Страница 24: ...0 340 Cost of a local call higher from mobile or public phones For further information visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personne...

Отзывы: