background image

Kit Components

MSB-M (Pack A)

(For wiring Units 1 and 2) 

Parts List

Part

               Qty 

Control Board
Communication Cable A  

Communication Cable B  

Cable tie bracket

                 2

Cable tie

               2

Instruction Sheet

                 1

MSB-C1 (Pack B)

(For wiring Units 3, 4 and 5) 

Parts List

Part

               Qty 

Communication Cable B  

Cable tie bracket

                 2 

Cable tie

               2 

Instruction Sheet

                 1 

Note: One MSB-C1 is required 
for each water heater (Units 3, 4,  

For Unit 1: 

1) Remove the screw from the 
sheet metal reinforcement plate 
located at the bottom of the 
water heater cabinet, and then 
use it to secure the Control Board
to the water heater cabinet.

2) Connect the  connector 
from Communication Cable A (18 
inch, 450 mm cable) to socket No. 1
on Control Board.  

1

1
1

1

and 5)

3) Connect the  connector from 
Communication Cable A to the 
4-pin socket located at the top of 
the water heater control board.
Communication Cable A 
ground wire terminal should be 
grounded with the PC board 
ground wire.

4) Attach the cable tie bracket to 
the bottom of the water heater 
cabinet using the existing screw. 
Loosely secure the cable tie 
through the bracket and around 
the communication cable. DO NOT 
TIGHTEN THE CABLE TIE AT THIS 
TIME - the Communication Cables B 
from the other water heaters must 
be secured by this cable tie. 

Communication Cables B

Water Heater 
Control 

Communication Cable A

Control Board

MSB Communication cable (MSB-C2)

bracket

                 1

If installing on a condensing 
water heater, refer to the addi-
tional instruction showing 
below. *

(18 in,  450 mm)

(9.8 ft,  3 m)

(9.8 ft,  3 m)

Screw

                 2

U306-1030(00)

Manifold Electronic Control System

Installation Instructions 

MSB-M

MSB-C1

Note:

• 

Up to 5 water heaters can be connected together using 

the MSB-M and MSB-C1 kits. 

United States & Canada:  For use with Rinnai Tankless Water 
Heaters (except for models V53e, V53i and R63LSe which must 
use pressure activation valves, PVA).  

• 

Disconnect all water heaters from their power source before carrying out 
the following installation procedures.

NOTE:  The front cover panels of each water heater must be removed prior 
to completing the following installation procedures.

WARNING

Please contact Rinnai if you have further questions on the 
applicable water heater models.   

• 

• 

When over 5 water heaters are connected together,

MSB-M units are connected using MSB-C2 kits. 

• 

Master

2nd

3rd

4th

5th

070 00012 32035 9

* These condensing water heaters require a bracket for the 
control board: 
 

RC98HPi (REU-KA3237FFUD)/RC98HPe (REU-KA3237WD)

 

/RC80HPi (REU-KA2530FFUD)/RC80HPe (REU-KA2530WD)

              /REU-KM3237FFUD/REU-KM3237WD/ REU-KM2635FFUD
             /REU-KM2635WD

Install the bracket with one screw as shown above and 
continue with the rest of the installation.

Install the bracket 

Attach the control board

Attach the control board to this bracket with one screw in Step 1. 

Ground wire of
Communication Cable A 

Ground wire of
Communication Cable A 

If multiple MSB-M are used, then at least three water heaters
should be connected to each MSB-M.
Ex: With 7 water heaters, one MSB-M should control 4 water 
heaters and the other MSB-M should control 3 water heaters. 

On the 2nd to 5th MSB boards, set to 1 unit ready.

Содержание MSB-C3

Страница 1: ... on each unit Random selection of the units required to supply the flow demand means that all units share the workload evenly All information is transmitted via communication cables to the slave units The master control also had an inbuilt fault detection system and will allocate a replacement unit should one fail MSB C1 C2 and C3 This MECS system has the capability of joining up to 25 Infinity un...

Страница 2: ...EU MSA3S REU SBC1 REUMSBC1 Decription Master Slave Joiner Location Inside Infinity1 External box2 Part number REU MSBM REU MSBMB REU MSBC1 REU MSBC2 No of water heaters 2 1 1 3 1 1 1 4 1 1 2 5 1 1 3 6 2 2 2 1 7 2 2 3 1 8 2 2 4 1 9 2 2 5 1 10 2 2 6 1 11 3 3 5 2 12 3 3 6 2 13 3 3 7 2 14 3 3 8 2 15 3 3 9 2 16 4 4 8 3 17 4 4 9 3 18 4 4 10 3 19 4 4 11 3 20 4 4 12 3 21 5 5 11 4 22 5 5 12 4 23 5 5 13 4 2...

Страница 3: ...2WC HD200i REU VR2632FFU REU VM2632FFUG HD250 REU VR3237WC REU VM3237WC HD250i REU VM3237FFUC XR26i REU V2632FFUG XR32 REU V3237WG HD250E REU K3237WC HD250Ei REU 3237FFUC 2 Can be used for all above models and MUST be used for all HD200 REU VM2630WC XR VT domestic models3 and Efficiency24 REU K2430 3 Reduced warranty applies to domestic models used in commercial applications ...

Страница 4: ...nstruction showing below 18 in 450 mm 9 8 ft 3 m 9 8 ft 3 m Screw 2 U306 1030 00 Manifold Electronic Control System Installation Instructions MSB M MSB C1 Note Up to 5 water heaters can be connected together using the MSB M and MSB C1 kits United States Canada For use with Rinnai Tankless Water Heaters except for models V53e V53i and R63LSe which must use pressure activation valves PVA Disconnect ...

Страница 5: ...ontrollers connected to the other units will provide maintenance codes for their respective units If water heaters do not use a temperature controller the temperature setting for the water heater with the Master MSB board is used If a water temperature over 140 degree F is desired then an MCC 91 controller needs to be connected to Master Control Board For proper operation it is not recommended tha...

Страница 6: ...h Rinnai Tankless Water Heaters except for models V53e V53i and R63LSe which must use pressure activation valves PVA x Disconnect all water heaters from their power source before carrying out the following installation procedures NOTE The front cover panels of each water heater must be removed prior to completing the following installation procedures WARNING Please contact Rinnai if you have furth...

Страница 7: ...For use with Rinnai Tankless Water Heaters except for models V53e V53i and R63LSe which must use pressure activation valves PVA Disconnect all water heaters from their power source before carrying out the following installation procedures NOTE The front cover panels of each water heater must be removed prior to completing the following installation procedures WARNING Please contact Rinnai if you h...

Отзывы: