2011 MECS: MSB-C1, C2  and C3

01-11

2

MECS

MSB-C1, MSB-C2, 

MSB-C3

What to use where

Older MECS system

New installs substitute

Replacement spare part

REU-MSA2M

REU-MSBM

REUMSBM

REU-MSA2S

REU-MSBC1

REUMSBC3

REU-MSA3M

REU-MSBMB

REUMSBMB

REU-MSA3S

REU-SBC1

REUMSBC1

Decription

Master

Slave

Joiner

Location

Inside Infinity

1

External box

2

Part number

REU-MSBM

REU-MSBMB

REU-MSBC1

REU-MSBC2

No. of water heaters

2

1

1

-

-

3

1

1

1

-

4

1

1

2

-

5

1

1

3

-

6

2

2

2

1

7

2

2

3

1

8

2

2

4

1

9

2

2

5

1

10

2

2

6

1

11

3

3

5

2

12

3

3

6

2

13

3

3

7

2

14

3

3

8

2

15

3

3

9

2

16

4

4

8

3

17

4

4

9

3

18

4

4

10

3

19

4

4

11

3

20

4

4

12

3

21

5

5

11

4

22

5

5

12

4

23

5

5

13

4

24

5

5

14

4

25

5

5

15

4

Refer Infinity model compatibility on next page

Содержание MSB-C3

Страница 1: ... on each unit Random selection of the units required to supply the flow demand means that all units share the workload evenly All information is transmitted via communication cables to the slave units The master control also had an inbuilt fault detection system and will allocate a replacement unit should one fail MSB C1 C2 and C3 This MECS system has the capability of joining up to 25 Infinity un...

Страница 2: ...EU MSA3S REU SBC1 REUMSBC1 Decription Master Slave Joiner Location Inside Infinity1 External box2 Part number REU MSBM REU MSBMB REU MSBC1 REU MSBC2 No of water heaters 2 1 1 3 1 1 1 4 1 1 2 5 1 1 3 6 2 2 2 1 7 2 2 3 1 8 2 2 4 1 9 2 2 5 1 10 2 2 6 1 11 3 3 5 2 12 3 3 6 2 13 3 3 7 2 14 3 3 8 2 15 3 3 9 2 16 4 4 8 3 17 4 4 9 3 18 4 4 10 3 19 4 4 11 3 20 4 4 12 3 21 5 5 11 4 22 5 5 12 4 23 5 5 13 4 2...

Страница 3: ...2WC HD200i REU VR2632FFU REU VM2632FFUG HD250 REU VR3237WC REU VM3237WC HD250i REU VM3237FFUC XR26i REU V2632FFUG XR32 REU V3237WG HD250E REU K3237WC HD250Ei REU 3237FFUC 2 Can be used for all above models and MUST be used for all HD200 REU VM2630WC XR VT domestic models3 and Efficiency24 REU K2430 3 Reduced warranty applies to domestic models used in commercial applications ...

Страница 4: ...nstruction showing below 18 in 450 mm 9 8 ft 3 m 9 8 ft 3 m Screw 2 U306 1030 00 Manifold Electronic Control System Installation Instructions MSB M MSB C1 Note Up to 5 water heaters can be connected together using the MSB M and MSB C1 kits United States Canada For use with Rinnai Tankless Water Heaters except for models V53e V53i and R63LSe which must use pressure activation valves PVA Disconnect ...

Страница 5: ...ontrollers connected to the other units will provide maintenance codes for their respective units If water heaters do not use a temperature controller the temperature setting for the water heater with the Master MSB board is used If a water temperature over 140 degree F is desired then an MCC 91 controller needs to be connected to Master Control Board For proper operation it is not recommended tha...

Страница 6: ...h Rinnai Tankless Water Heaters except for models V53e V53i and R63LSe which must use pressure activation valves PVA x Disconnect all water heaters from their power source before carrying out the following installation procedures NOTE The front cover panels of each water heater must be removed prior to completing the following installation procedures WARNING Please contact Rinnai if you have furth...

Страница 7: ...For use with Rinnai Tankless Water Heaters except for models V53e V53i and R63LSe which must use pressure activation valves PVA Disconnect all water heaters from their power source before carrying out the following installation procedures NOTE The front cover panels of each water heater must be removed prior to completing the following installation procedures WARNING Please contact Rinnai if you h...

Отзывы: