Rinnai MC-503RC Скачать руководство пользователя страница 6

Rinnai New Zealand

Wireless Installation and Operation: C 03-09

6

General Information

The wireless controllers are classified as short range radio communications devices 

and referred to as ‘Low Interference Potential Devices’ (LIPD’s). They operate in the 

same radio frequency as garage door openers and keyless automobile entry systems. 

although interference with other LIPD’s is unlikely, it is not guaranteed interference will 

not occur.

They should not be used if there is a chance of interference with other devices such as medical 

devices and fire alarms. Please verify this before installation.

While the hot water outlets are open the set temperature may be lowered but not raised above 

43 °C. also transfer of priority between controllers is not possible. These are safety features.

Radio communications

Safety features 

Water controllers and transceivers do not contain serviceable parts and must only be 

serviced and repaired by an authorised Rinnai Service Centre.

Servicing

Principle of operation

a wireless controller installation utilises a transceiver and up to 4 wireless controllers. There 

is a ‘two way’ communication between the transceiver and controllers. The transceiver is 

connected by electrical cable to the water heater. The transceiver transmits control signals 

received from the wireless controllers operated by the user to the water heater. The transceiver 

transmits operational status signals from the water heater to the controllers.

Water controllers allow precise temperature control by the user. When used correctly, the hot 

water unit will deliver the selected temperature, even when the water flow is varied, or more 

than 1 tap is in use. Each remote controller can be individually programmed, however the 

water heater can only deliver 1 set temperature at any time.

Water resistance

The MC-503RC Wireless Water Controller is a water resistant device, however excessive 

exposure to water may result in damage to the controller.

Do not immerse the controller in water

avoid direct exposure to water or steam as these conditions may cause a malfunction

always avoid exposure to water when the battery compartment is open

When cleaning your controller use only a damp cloth and mild detergent.

Содержание MC-503RC

Страница 1: ...i MC 502RC Wireless Controllers and Transceivers Before starting to avoid damage to electrical components switch off and remove the power plug of the water heater Do not fix or permanently attach eith...

Страница 2: ...s only This warranty will not apply if for example the product has been improperly installed or is otherwise installed contrary to manufacturer s recommendations has been damaged during or after insta...

Страница 3: ...or additional information contact Rinnai on 0800 RINNAI 0800 746 624 Before Installation 4 Available Controller Configurations 4 General Information 5 Wireless Controller Batteries 7 Quick Start Instr...

Страница 4: ...ss installations A maximum of 4 water controllers can be fitted in combination and used as follows Only 1 master controller can be installed this can be a MC 100V Kitchen Deluxe will always function a...

Страница 5: ...the shower recess Refer next page for further details Signal strength Take signal strength into consideration when determining the best location for the transceiver and controller In some cases build...

Страница 6: ...eless controller installation utilises a transceiver and up to 4 wireless controllers There is a two way communication between the transceiver and controllers The transceiver is connected by electrica...

Страница 7: ...er Failure to do so may allow water to enter the controller causing damage Remove controller from wall mounting bracket Open battery compartment turn battery cover a full turn anti clockwise Insert ba...

Страница 8: ...ween the controller and transceiver must not exceed 20 m Turn on the power to the water heater The transceiver automatically assigns channels to any wired controllers Press the entry button on the tra...

Страница 9: ...the Quick Connect cable connector door open and thread the cable through the weather seal of the access hole Allow sufficient cable length so that the sheath of the cable can be secured with the cabl...

Страница 10: ...1 No 2 No 3 Max Temp Maimtenance Temp Volume On Off Water Heater Setting the maximum temperature at the transceiver Turn on the power to the water heater Set the transceivers s maximum water temperatu...

Страница 11: ...will take approximately 5 seconds Once the controller is tuned the controller channel LED on the transceiver will become steady and the controller will switch to screen D or E From screen D press the...

Страница 12: ...he LED will go out to signify that this channel is now unassigned Remove batteries from wireless controller This will reset the wireless controller and complete the un install process 2 MC No 1 No 2 N...

Страница 13: ...ck has been activated WATER CONTROLLER STATUS INDICATORS Turning on When the water heater is off only the communications and battery status indicators are displayed To turn the water heater on press t...

Страница 14: ...se labelled Bathroom This is a safety feature to reduce risk of burns Child lock function To activate the child lock function Press the key button for 3 seconds The child lock indicator will illuminat...

Страница 15: ...controllers have been reset When the wireless transceiver is installed it automatically detects any wired water controllers already connected to the water heater The LEDs of the channels assigned to...

Страница 16: ...rned on at water heater and gas meter cylinder Check there are no obstructions to the flue outlet 14 Remaining flame safety device Service call 16 Over temperature warning Service call 32 Outgoing wat...

Отзывы: