Rinnai MC-503RC Скачать руководство пользователя страница 11

Rinnai New Zealand

Wireless Installation and Operation: C 03-09

Wireless Water Controller Installation

Installing wireless water controllers

Ensure the power to the water heater is switched on.

Press the ‘Entry’ button on the transceiver for approximately 2 

seconds. This will select a wireless controller channel for tuning. The 

first unassigned wireless controller channel LED will begin a fast flash, 

signifying this channel has been selected for tuning.

 

 

The default order of channel selection is as follows: ---> MC ---> No. 

 ---> No. 2 ---> No. 3

 

Select a wireless controller for tuning to the unassigned transceiver channel, insert 

batteries and close battery compartment. after battery installation the controller will 

momentarily display an initialisation screen (a), that will switch to screen (B) or (C).

 

If screen (B) is displayed, press and hold the ‘On/Off’ button until screen (C) is displayed. 

This takes approximately 2 seconds.

 

From screen (C), press the ‘On/Off’ button once to start the tuning process which will take 

approximately 5 seconds. Once the controller is tuned the controller channel LED on the 

transceiver will become steady and the controller will switch to screen (D) or (E).

 

From screen (D) press the ‘On/Off’ button once or from screen (E) press the ‘Transfer’  

button once to complete tuning of this channel. at this point screen (F) will be displayed. 

The wireless controller is now tuned and ready to control delivery temperature of the water 

heater. 

apply one of the self-adhesive identification stickers to the rear of the controller, ensuring 

that the Master Controller sticker is only applied to the wireless controller tuned to channel 

MC. 

 

The wireless master controller is the only wireless controller of selecting maximum delivery 

temperatures exceeding 50 °C. 

.

2.

3.

4.

5.

6.

Entry

Entry

Controllers

MC

No. 1

No. 2

No. 3

(C)

O R

Press       for

approximately

3 seconds

(B)

(D)

(E)

Press         once

(A)

Press       once

to start the tuning

process, this takes

approximately

5 seconds

Press       once

O R

(F)

Installing multiple wireless water controllers

To install subsequent wireless water controllers, repeat steps 1 - 6 for each additional 

controller. Screw transceiver cover in place once all wireless controllers are installed.

Содержание MC-503RC

Страница 1: ...i MC 502RC Wireless Controllers and Transceivers Before starting to avoid damage to electrical components switch off and remove the power plug of the water heater Do not fix or permanently attach eith...

Страница 2: ...s only This warranty will not apply if for example the product has been improperly installed or is otherwise installed contrary to manufacturer s recommendations has been damaged during or after insta...

Страница 3: ...or additional information contact Rinnai on 0800 RINNAI 0800 746 624 Before Installation 4 Available Controller Configurations 4 General Information 5 Wireless Controller Batteries 7 Quick Start Instr...

Страница 4: ...ss installations A maximum of 4 water controllers can be fitted in combination and used as follows Only 1 master controller can be installed this can be a MC 100V Kitchen Deluxe will always function a...

Страница 5: ...the shower recess Refer next page for further details Signal strength Take signal strength into consideration when determining the best location for the transceiver and controller In some cases build...

Страница 6: ...eless controller installation utilises a transceiver and up to 4 wireless controllers There is a two way communication between the transceiver and controllers The transceiver is connected by electrica...

Страница 7: ...er Failure to do so may allow water to enter the controller causing damage Remove controller from wall mounting bracket Open battery compartment turn battery cover a full turn anti clockwise Insert ba...

Страница 8: ...ween the controller and transceiver must not exceed 20 m Turn on the power to the water heater The transceiver automatically assigns channels to any wired controllers Press the entry button on the tra...

Страница 9: ...the Quick Connect cable connector door open and thread the cable through the weather seal of the access hole Allow sufficient cable length so that the sheath of the cable can be secured with the cabl...

Страница 10: ...1 No 2 No 3 Max Temp Maimtenance Temp Volume On Off Water Heater Setting the maximum temperature at the transceiver Turn on the power to the water heater Set the transceivers s maximum water temperatu...

Страница 11: ...will take approximately 5 seconds Once the controller is tuned the controller channel LED on the transceiver will become steady and the controller will switch to screen D or E From screen D press the...

Страница 12: ...he LED will go out to signify that this channel is now unassigned Remove batteries from wireless controller This will reset the wireless controller and complete the un install process 2 MC No 1 No 2 N...

Страница 13: ...ck has been activated WATER CONTROLLER STATUS INDICATORS Turning on When the water heater is off only the communications and battery status indicators are displayed To turn the water heater on press t...

Страница 14: ...se labelled Bathroom This is a safety feature to reduce risk of burns Child lock function To activate the child lock function Press the key button for 3 seconds The child lock indicator will illuminat...

Страница 15: ...controllers have been reset When the wireless transceiver is installed it automatically detects any wired water controllers already connected to the water heater The LEDs of the channels assigned to...

Страница 16: ...rned on at water heater and gas meter cylinder Check there are no obstructions to the flue outlet 14 Remaining flame safety device Service call 16 Over temperature warning Service call 32 Outgoing wat...

Отзывы: