background image

14 

 

TEMPERATURE CONTROLS 

Using the Temperature Controllers 
 

Press the 

ON/OFF 

button 

o n  

a  

t e m p e r a t u r e 

controller  after  making 
sure  that  water  is  not 
flowing. 
 
The  system  will  become 
active,  the  temperature 
will  default  to  40°C  and 
the  controller  that  turned 
the  system  on  will  have 
priority. 
 
The  temperature  setting 
on  the  controller  will  light 
up. 

Adjusting Temperature 
 

Simply  press 
the  Hot  Water 
T e m p e r a t u r e 
Up  or  Down 
arrow button  
 
 
 
 
 
 
until the desired 
temperature  is 
displayed  on 
t h e  

d i g i t a l 

display. 

Using Hot Water 

 
To operate the heater, simply turn any hot water 
tap  on.  This  will  automatically  light  the  burner 
providing  hot  water.  The  red 

IN  USE 

indicator 

will glow on the temperature controller. 

To turn off your hot water system 

 
During normal operation the system is left on.

 

 
To turn the system off simply press the 

ON/OFF

 

button  on  any  temperature  controller  (where 
fitted).  This  will  shut  the  water  heater  down 
completely  including  the  temperature  controller 
digital display. 
 
The Digital Monitor will go out. 
 
If hot water taps are opened when the Rinnai  is 
off, cold water will flow from the taps. 
 
If  the  system  is  to  be  left  off  over  the  winter  be 
sure  to  drain  it  down  if  there  is  a  possibility  of 
freezing temperatures. 

Using High Temperature Display Controllers 

 
You will need to program the Master controller if you want to display and use 
temperatures  over  50°C.  Programming  only  needs  to  be  done  on  Master 
universal controller; other universal controllers will not allow this. 
Deluxe  Kitchen  controllers  are  supplied  already  programmed  to  allow  high 
temperatures. 
 

STEP  1: 

On the Master controller only press and hold the 

Transfer 

and 

ON/

OFF 

buttons  simultaneously  (see  Fig.  1)  until  a  “beep”  is  heard  (approx.  5 

seconds). 

 
STEP  2:

 When the Primary controller is switched on it should be possible to select temperatures higher 

than 50ºC. If not repeat STEP 1. 

 

If  the  master  controller  is  replaced,  repeat  STEP  1  above 
for the new controller. 

Fig. 1 

NOTE

COOLER

 

HOTTER

 

Содержание INFINITY 26i

Страница 1: ...inuous Flow Water Heater Important Read these instructions carefully before attempting installation or use of this appliance All work must be carried out by competent persons REU VR2632FFUD 26i REU VR...

Страница 2: ...E HD70e REU VRM3237WHD E HD70i REU VRM3237FFUHD E Certificate numbers E0841 5386 Rev 5 E0716 5360 Rev 05 E1061 5498 Rev 1 E1060 5498 Rev 1 ID number 0461BP0795 0461BO0739 0461BS0903 0461BS0903 Date of...

Страница 3: ...3 This manual is intended for use by Gas Safe Registered Engineers November 2012...

Страница 4: ...4 CONTENTS 3 CONTENTS...

Страница 5: ...5 Glossary of Terms and Symbols...

Страница 6: ...n 3 C above the selected temperature the burner is shut OFF and only turned ON again when the temperature falls to below the selected temperature The burner lights automatically when the hot water tap...

Страница 7: ...m3 hr G31 Input Qm Hi Hs Useful output Pm 4 01 4 36 3 49 4 01 4 36 3 49 kW G31 flow normal operating conditions Mm 0 31 0 31 Kg hr Gas Consumption Capacities nominal condit Hi net calorific value Hs...

Страница 8: ...8 WATER FLOW CHARACTERISTICS 26i HD50e HD50i HD70e HD70i...

Страница 9: ...9 DIMENSIONS 26i HD50i...

Страница 10: ...10 DIMENSIONS HD50e...

Страница 11: ...6 48 50 C Master universal Controller 37 38 39 40 41 42 43 44 45 46 48 50 55 C 60 65 C HD Deluxe Bathroom Controller Hot Water Delivery 37 38 39 40 41 42 43 44 45 46 48 50 C Bath fill Delivery 37 38 3...

Страница 12: ...erred The temperature set point on the controller with priority can always be lowered but the set point can only be raised to 43 C Other controllers are unable to take priority or change the delivery...

Страница 13: ...noise Table B Maintenance Monitor Section No Information Given Units Given Data Range O1 Water Flow sensor Recognition Flow Rate Liter per Min 0 O2 Water Outlet Thermistor Temperature C 0 O3 Combusti...

Страница 14: ...This will shut the water heater down completely including the temperature controller digital display The Digital Monitor will go out If hot water taps are opened when the Rinnai is off cold water wil...

Страница 15: ...r the system Select the desired temperature using the Hot water temp buttons The selected temperature will be displayed on all controller displays This is the water temperature which will be supplied...

Страница 16: ...elected on a controller and priority of temperature selection is transferred to another controller then back again the temperature on the controller will automatically drop to 50 C If the set point is...

Страница 17: ...To bypass this see page 11 Positioning the temperature controls the following points should be taken into account Fit the controls out of reach of children suggested height from the floor 1 5m Avoid...

Страница 18: ...18 OPERATION HD50e 26i HD50i...

Страница 19: ...team 4 Overheat Safety Bi metal Switch This Bi metal Switch is fixed at the inlet bend of the Heat Exchangers final pass If the temperature outlet from the heat exchanger reaches 97 C the bi metal swi...

Страница 20: ...20 WIRING DIAGRAM 26i HD50e HD50i...