background image

12 

 

TEMPERATURE CONTROLS 

Remote  temperature controllers  provide  control over  the  water  temperature.  Rinnai  water  heaters  can 
be operated with 1, 2, 3, 4 or no temperature controllers. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Each  time  a  button  is  pressed,  a  BEEP  will  sound.  The  BEEP  sound  can  be  muted  by 

depressing the Temperature Controller Up and Down buttons simultaneously for more than 
3  seconds.  This  can  be  done  for  each  Temperature  Controller.  To  return  to  original 
settings, repeat this step. 

 
Safety features 

 
Whilst    the  hot  water  tap  is  open,  the  following 
safety features apply: 
 

Temperature selection cannot be transferred. 

 

The  temperature  set  point  on  the  controller 
with  priority  can  always  be  lowered,  but    the 
set point can only be raised to 43°C. 

 

Other controllers are unable to take priority or 
change the delivery temperature of the water. 

 

If off, the controller cannot be turned on. 

 
The temperature  of the outgoing  water 
is  constantly  monitored  by  a  built  in 
sensor. 
 
 
If  the  temperature  of  the  outgoing 

hot  water  rises  to  more  than  3ºC  above  the 
selected  temperature  shown  on  the  digital 
display,  or  the  preset  limit  if  controllers  are  not 
fitted, the burner will automatically go out. 
 
The red operation indicator will also go out. 
 
The  burner  will  ignite  again  once  the  outgoing 
hot water temperature falls to that shown on the 
digital  display  (or  the  pre-set  limit  of  the  Rinnai 
heater). 

NOTE

NOTE

Содержание INFINITY 26i

Страница 1: ...inuous Flow Water Heater Important Read these instructions carefully before attempting installation or use of this appliance All work must be carried out by competent persons REU VR2632FFUD 26i REU VR...

Страница 2: ...E HD70e REU VRM3237WHD E HD70i REU VRM3237FFUHD E Certificate numbers E0841 5386 Rev 5 E0716 5360 Rev 05 E1061 5498 Rev 1 E1060 5498 Rev 1 ID number 0461BP0795 0461BO0739 0461BS0903 0461BS0903 Date of...

Страница 3: ...3 This manual is intended for use by Gas Safe Registered Engineers November 2012...

Страница 4: ...4 CONTENTS 3 CONTENTS...

Страница 5: ...5 Glossary of Terms and Symbols...

Страница 6: ...n 3 C above the selected temperature the burner is shut OFF and only turned ON again when the temperature falls to below the selected temperature The burner lights automatically when the hot water tap...

Страница 7: ...m3 hr G31 Input Qm Hi Hs Useful output Pm 4 01 4 36 3 49 4 01 4 36 3 49 kW G31 flow normal operating conditions Mm 0 31 0 31 Kg hr Gas Consumption Capacities nominal condit Hi net calorific value Hs...

Страница 8: ...8 WATER FLOW CHARACTERISTICS 26i HD50e HD50i HD70e HD70i...

Страница 9: ...9 DIMENSIONS 26i HD50i...

Страница 10: ...10 DIMENSIONS HD50e...

Страница 11: ...6 48 50 C Master universal Controller 37 38 39 40 41 42 43 44 45 46 48 50 55 C 60 65 C HD Deluxe Bathroom Controller Hot Water Delivery 37 38 39 40 41 42 43 44 45 46 48 50 C Bath fill Delivery 37 38 3...

Страница 12: ...erred The temperature set point on the controller with priority can always be lowered but the set point can only be raised to 43 C Other controllers are unable to take priority or change the delivery...

Страница 13: ...noise Table B Maintenance Monitor Section No Information Given Units Given Data Range O1 Water Flow sensor Recognition Flow Rate Liter per Min 0 O2 Water Outlet Thermistor Temperature C 0 O3 Combusti...

Страница 14: ...This will shut the water heater down completely including the temperature controller digital display The Digital Monitor will go out If hot water taps are opened when the Rinnai is off cold water wil...

Страница 15: ...r the system Select the desired temperature using the Hot water temp buttons The selected temperature will be displayed on all controller displays This is the water temperature which will be supplied...

Страница 16: ...elected on a controller and priority of temperature selection is transferred to another controller then back again the temperature on the controller will automatically drop to 50 C If the set point is...

Страница 17: ...To bypass this see page 11 Positioning the temperature controls the following points should be taken into account Fit the controls out of reach of children suggested height from the floor 1 5m Avoid...

Страница 18: ...18 OPERATION HD50e 26i HD50i...

Страница 19: ...team 4 Overheat Safety Bi metal Switch This Bi metal Switch is fixed at the inlet bend of the Heat Exchangers final pass If the temperature outlet from the heat exchanger reaches 97 C the bi metal swi...

Страница 20: ...20 WIRING DIAGRAM 26i HD50e HD50i...

Отзывы: