6.1 RINNAI I SERIES WALL CONTROL
The Rinnai I Series Evaporator Module comes supplied with
a Rinnai wall control� The loom is supplied and connected to
the Rinnai Evaporator Module PCB ready for routing to wall
control�
6.2 POSITIONING THE RINNAI WALL CONTROL
The Controller in Auto mode will constantly monitor the
temperature inside the house, switching the Rinnai I Series
cooler ON and OFF to maintain the target comfort level
selected� To do this effectively, the wall control shall be
positioned correctly:
•
Install the wall control within the area being cooled� It is important that the Wall Control is placed in a position
that will provide the most accurate reading of the temperature within the area being cooled�
•
Attach to an internal wall� The temperature difference on an external wall can affect the reading, so always
mount the wall control on an internal wall� Also keep the hole in the wall for your wiring as small as possible and
seal it to prevent draughts from within the wall cavity affecting the temperature sensing�
•
The Wall Control should be approximately 1500mm above floor level.
•
Avoid hot spots� Keep it as far away as possible from heat sources, e�g� above electrical equipment, direct
sunlight and walls backing onto wall-ovens and stoves�
•
Avoid cold spots� Ensure that the Wall Control is not affected by draughts coming through doorways, windows
and stairwells, and is not placed too close to cooling outlets�
•
Avoid dead spots� Do not site it in areas with little or no air circulation, e�g� behind doors, in corners or alcoves�
•
Interference from other electrical connections� Ensure the thermostat and wiring loom is kept away from other
electrical, data and antenna cables�
6.3 MOUNTING OF WALL CONTROL
1� Ensure power is isolated from the Evaporator Module�
2�
Remove “Backing Plate” with a small flat screw driver at one of the three removal points.
3� Using the “Backing Plate” as a template on the plaster wall, mark out the two “Mounting Holes” and “Loom
Connection Recess”�
4� Cut out the “Loom Connection Recess”�
5�
Drill 8mm holes in “Mounting Hole” location and fit supplied plaster plugs.
6� Mount backing plate with supplied screws�
7�
Pull loom through the plaster cut out and connect the five pin terminal to “Loom Connection” point on fascia
back�
8� Mount “Wall Control Fascia” to “Wall Control Backing Plate”�