background image

Rinnai 21 

HOTFLO (HFE Series) Electric Storage Water Heater OIM

WARNING

Commissioning activities 

MUST BE

carriedoutbyanauthorisedperson.

DO NOT

switchontheelectricpowersupplyuntilthewaterheaterisfilledcompletelywithwater.

TO FILL & TURN ‘ON’ THE WATER HEATER 

1�  Open all hot water taps in the building, including the shower�
2�  Open the cold water isolation valve to water heater� Air will now be forced out of the taps� 
3�  Close each tap when water runs freely without air bubbles�
4�  Check all plumbing connections and pipe work for water leaks� 
5�  Connect the water heater to the electricity supply, and turn the electric power supply 'ON'�

TO TURN ‘OFF’ THE WATER HEATER 

It may be necessary to turn off a water heater after installation and commissioning, for example during building 

activities or if the premises are vacant� 
1�  Isolate or turn 'OFF' the water heater at the electricity supply�
2�  Close the cold water isolation valve at the inlet to the water heater�

COMMISSIONING

Содержание HOTFLO HFE125S18

Страница 1: ...egulation All local regulatory requirements including all local OH S requirements This appliance must be installed maintained and removed by a Qualified Person For continued safety of this appliance i...

Страница 2: ...Rinnai 2 HOTFLO HFE Series Electric Storage Water Heater OIM This page is intentionally blank...

Страница 3: ...ns 12 Installation Methods 13 Hot Water Plumbing System Example No Temperature Limiting Device 13 Hot Water Plumbing System Example With Temperature Limiting Device 13 Hot water plumbing system Exampl...

Страница 4: ...Rinnai 4 HOTFLO HFE Series Electric Storage Water Heater OIM This page is intentionally blank...

Страница 5: ...rules and regulations For continued safety of this appliance it must be installed operated and maintained in accordance with the manufacturer s instructions This appliance is heavy use 2 people or mec...

Страница 6: ...trades person WARNING The thermostat setting must only be adjusted by an Electrician or other suitably qualified trades person The access cover to the element and thermostat must only be removed by an...

Страница 7: ...by a qualified person It is normal for the PTR valve to release a small quantity of water through the drain pipe during heating If the valve dribbles or leaks continuously try easing the valve gear fo...

Страница 8: ...eated during the set period and stored The Off Peak supply is usually cheaper Electricity supply types and tariffs vary according to the local electricity authority Twin Element Model A vitreous ename...

Страница 9: ...may need to be increased Contact your installer or Rinnai to discuss adjusting the thermostat No water from the hot tap Restriction in the hot tap or failure of the cold water supply to the heater Che...

Страница 10: ...D WARNING LABELS LEFT COLD WATER INLET Connection RP 3 4 20mm LEFT HOT WATER OUTLET Connection RP 3 4 20mm use a union connection and Insulate Hot water pipe PTR VALVE DRAIN PIPE Supplied by Installer...

Страница 11: ...y F Electrical Entry Upper Element G HFE25S 452 490 415 297 153 80 HFE50S 694 490 415 524 158 80 HFE80S 900 590 515 683 225 155 HFE125S 1245 590 515 1020 225 155 HFE160S 1530 590 515 1310 225 155 HFE2...

Страница 12: ...4 HFE160T36 HFE160T48 160 1800 2400 3600 4800 1800 2400 3600 4800 HFE200S24 HFE200S36 HFE200S48 200 2400 3600 4800 HFE250SSL36 HFE250SSL48 250 3600 4800 HFE250T36 HFE250T48 250 3600 4800 3600 4800 HFE...

Страница 13: ...E LIMITING DEVICE KITCHEN LAUNDRY ENSUITE BATHROOM TEMPERED Supply NON TEMPERED SUPPLY NON RETURN VALVE TEMPERATURE LIMITING DEVICE TLD NON RETURN VALVE NON RETURN VALVE PLV 500 kPa Not Supplied with...

Страница 14: ...t Supplied with all models ECV Not Supplied 700 kPa or 850 kPa ISOLATING VALVE PTR VALVE Supplied 850 kPa or 1000 kPa WATER HEATER COLD Supply ISOLATING VALVE NON RETURN VALVE FLOW RETURN PUMP ISOLATI...

Страница 15: ...0 kPa WATER HEATER COLD Supply NON RETURN VALVE FLOW RETURN PUMP ISOLATING VALVE UNTEMPERED SUPPLY TLD CAUTION Valves with pressure ratings other than specified are unsuitable and MUST NOT be used For...

Страница 16: ...n occur as a result of water leakage the water heater MUST BE installed with a safe tray overflow tray and drain Construction installation and draining of the safe tray MUST comply with local regulato...

Страница 17: ...s under Installation Methods WARNING Valves with pressure ratings other than specified MUST NOT be used An isolation valve and non return valve MUST BE fitted in the cold water supply to the water hea...

Страница 18: ...BE fitted to the valve outlet in accordance with the section Relief Valve Drain Lines on the bottom of page 18 The valve body MUST BE insulated in accordance with local regulatory requirements and AS...

Страница 19: ...g element Check the available tariffs with the local electricity supplier The Off Peak overnight is usually the most economical for the customer Electrical Connections WARNING The water heater MUST BE...

Страница 20: ...fore removing the access cover to the element and thermostat The access cover to the element and thermostat MUST ONLY BE removed by an Electrician or other suitably qualified trades person The thermos...

Страница 21: ...Air will now be forced out of the taps 3 Close each tap when water runs freely without air bubbles 4 Check all plumbing connections and pipe work for water leaks 5 Connect the water heater to the ele...

Страница 22: ...ce please call our National Help Line Rinnai recommends that this appliance be serviced every year Head Office 100 Atlantic Drive Keysborough VIC 3173 P O Box 460 Braeside Victoria 3195 Product Sales...

Отзывы: