Rinnai 17
Split AC OM
GENERAL MAINTENANCE
COMPONENT
DESCRIPTION
INTERVAL
Indoor unit
Clean the Indoor unit outer surface by using a soft, dry cloth.
Regularly
Replace the remote control batteries�
As needed or once per year
Professional service
Once per year
Outdoor unit
Professional service
Once per year
CAUTION
Turn off the power before you perform any maintenance; otherwise it may cause electric shock.
NEVER
use water that is hotter than 40°C when you clean the filters. It may cause deformation or
discolouration.
NEVER
use volatile substances when you clean the filters. They may damage the surface of the
product.
NOTE
Make sure have your appliance professionally serviced once per year, failing to do so may
decrease the operational efficiency or increase energy consumed.
CLEANING THE AIR FILTER
Clean the air filter once every 2 weeks or more if necessary.
1�
Turn off the power
2� Open the front cover�
3�
Hold the tab of the air filter, lift it up slightly and remove it from the unit.
4�
Clean the filter with a vacuum cleaner or with warm water. If dirt is difficult to remove, wash the filter in
lukewarm water with mild detergent.
5�
Dry the filter in the shade.
6�
Ensure to re-insert the filter securely after cleaning, observing the same orientation as when removed.
NOTE
Failure to clean the filters regularly can cause condensation to form and drip from the indoor unit
when operated in cooling mode during humid conditions.
If you need more filters, please contact Rinnai.
CARE & MAINTENANCE