Rinnai Direct Vent Service Manual
17
Troubleshooting
(FM) Convection Fan Motor: (Connector CN3)
AC Motor 60 Hz, 100VAC
Read voltage across:
Voltage Potential
Read resistance
Pin Numbers
Black-Red 40-105
VAC
100-120
Ω
1-2
* Be sure to check for obstructions to blades. Check the capacitor before replacing motor.
(PS) Pressure Sensor:
(Connector CN13)
Electronic Pressure Switch, 125 V, 0.1 A
Electronic
0.31 in (8.0 mm) WC
ON
0.11 in (2.8 mm) WC
OFF
5 VDC
Note: Ensure clear and black hose from pressure switch to blower air chamber is not blocked or
crimped with any obstructions including spider webs.
(TH) Room Thermistor:
Check thermistor by inserting meter leads into each end of thermistor plug. Set your meter to the
200 K
Ω
scale. Apply heat to the thermistor bulb and the resistance should decrease. Apply cold
and the resistance should increase. Examples of readings:
41ºF=91K
Ω
50ºF=65K
Ω
68ºF=39K
Ω
86ºF=23K
Ω
(FR) Flame Rod
Set your meter to read micro-amps (µ). Located on the combustion chamber, the lfame rod proofs
flame for proper operations. A properly grounded electrical supply is a must. Flame rod current
through this rod should range between 4 to 8 icro amps depending on gas type. Low fire flame
current should be 1.2 to 2.0 micro amps.
Improperly setup and /or converted units can soot and cause hard lockouts. If carbon is found on the
flame rod, clean the carbon from it. Then you need to confirm your manifold differential gas pressure on
Hi fire and Lo fire is correct. Insure primary and secondary air dampers are correct. Also, check to ensure
proper orifices were placed in the unit..
IMPORTANT INFORMATION CONCERNING HARD LOCKOUTS:
Other items that can cause hard lockouts are: improper sized gas lines, low gas pressures or pressure drops due
to other appliances on the gas system, spider webs in the burner and air intake of vent system, improper ground
or no ground at receptacle, supply regulators freezing up or defective, voltage drops or bad receptacles, winds in
excess of 40 mph causing turbulence inside the vent terminal, etc.
(OHS1, OHS2, TF) Safety Circuit Check: CN8
Check for continuity reading from pin #1 white wire to pin #5 white wire. If you do not read continuity through this
circuit, locate defective switch and replace that component. Then determine what caused overheat condition.
(MS) Main Switch: CN11
Disconnect CN11 from PCB, being careful not to break wires. Read Blue to Blue, pin #9 and 10 on 40K
Ω
. When
ON/OFF is in the ON position, you should read 10--18K
Ω
. When released, you should read open or 0
Ω
Wiring harness, connectors, and fuses should be checked if all above readings are normal.
(RT) Room Temperature Control:
Integrated into the PCB program and works in conjunction with the thermistor as noted below.
RHFE-263FA
RHFE-263FAII
RHFE-263RFA
Содержание Energysaver RHFE-1004FTA
Страница 14: ...14 Rinnai Direct Vent Service Manual RHFE 201FA RHFE 201RFA Wire Diagram ...
Страница 15: ...Rinnai Direct Vent Service Manual 15 RHFE 201FA RHFE 201RFA Ladder Diagram ...
Страница 18: ...18 Rinnai Direct Vent Service Manual RHFE 263FA RHFE 263FAII RHFE 263RFA Wire Diagram ...
Страница 19: ...Rinnai Direct Vent Service Manual 19 Ladder Diagram RHFE 263FA RHFE 263FAII RHFE 263RFA ...
Страница 26: ...26 Rinnai Direct Vent Service Manual RHFE 431FA Series RHFE 556FA FTRA Wire Diagram ...
Страница 27: ...Rinnai Direct Vent Service Manual 27 RHFE 556FAIII Wire Diagram ...
Страница 28: ...28 Rinnai Direct Vent Service Manual RHFE 556FTRAIII Wire Diagram ...
Страница 32: ...32 Rinnai Direct Vent Service Manual RHFE 431WTA Wire Diagram ...
Страница 33: ...Rinnai Direct Vent Service Manual 33 RHFE 556WTA Wire Diagram ...
Страница 45: ...Rinnai Direct Vent Service Manual 45 RHFE 551FA Fault Finding Summary ...
Страница 46: ...46 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 1 ...
Страница 47: ...Rinnai Direct Vent Service Manual 47 RHFE 551FA Fault Finding Chart 2 ...
Страница 48: ...48 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 3 ...
Страница 49: ...Rinnai Direct Vent Service Manual 49 RHFE 551FA Fault Finding Chart 4 ...
Страница 50: ...50 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 5 ...
Страница 51: ...Rinnai Direct Vent Service Manual 51 RHFE 551FA Fault Finding Chart 6 ...
Страница 52: ...52 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 7 ...
Страница 53: ...Rinnai Direct Vent Service Manual 53 RHFE 551FA Fault Finding Chart 8 ...
Страница 54: ...54 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 9 and 10 ...
Страница 55: ...Rinnai Direct Vent Service Manual 55 RHFE 551FA Wire Diagram ...
Страница 58: ...58 Rinnai Direct Vent Service Manual RHFE 1001FA Fault Finding Chart ...
Страница 59: ...Rinnai Direct Vent Service Manual 59 RHFE 1001FA Fault Finding Chart ...
Страница 60: ...60 Rinnai Direct Vent Service Manual RHFE 1001FA Fault Finding Chart ...
Страница 61: ...Rinnai Direct Vent Service Manual 61 RHFE 1001FA Wire Diagram ...
Страница 64: ...64 Rinnai Direct Vent Service Manual RHFE1001FA VA Fault Finding Chart ...
Страница 65: ...Rinnai Direct Vent Service Manual 65 RHFE1001FA VA Fault Finding Chart ...
Страница 66: ...66 Rinnai Direct Vent Service Manual RHFE1001FA VA Fault Finding Chart ...
Страница 67: ...Rinnai Direct Vent Service Manual 67 RHFE1001FA VA Fault Finding Chart ...
Страница 68: ...68 Rinnai Direct Vent Service Manual RHFE 1001FA VA Wire Diagram Wire Diagram Ladder Diagram ...
Страница 73: ...Rinnai Direct Vent Service Manual 73 RHFE 1004FA RHFE 1004RFA RHFE 1004FTA Wire Diagram ...