 10

  

 |   

Composite recess box installation guide:10847-D 04-18

Installing the water heater

Nylock nuts

Bracket slot

Fixing 

studs

A-Series

A-Series

Existing bracket

Replacement bracket

Ensure the water heater model and serial number is copied legibly from the 
data plate, left hand side of the appliance, to the sticker on the inside of the 
recess box cover—this must be done. The model and serial numbers are 
required for servicing, troubleshooting, warranty claims, and parts supply.

Installation
1.  Remove the two M5 nylock nuts from the 

fixing studs of the box. 

2.  For Rinnai A-Series models ONLY, remove 

the existing lower water heater bracket, 
secured with two screws and replace with 
the one provided in the kit. 
 
This allows the water heater to line up with 
the fixing holes of the recess box. 
 
 
 
 
 
 
 
 
 
 
 
 

3.  Insert the upper mounting bracket of the 

water heater into the bracket slot. 

4.  Push the appliance up until the lower 

mounting bracket aligns with the fixing 
studs and secure with the two nylock nuts 
removed in step 1. 
 
 
 
 
 
 
 
 
 
 
 
 

5.  Select the locations for the pipe and 

electrical entry to the box. Remove the 
blanking plugs from the holes that will 
be used and replace with the grommets 
supplied, otherwise use the supplied 
grommets for other drilled holes. The pipe 
entry points are elevated to prevent water 
ingress. 

6.  Complete the gas and water connections. 

It is recommended that flexible gas and 
water connectors are used to make the 
final connections—this allows the water 
heater to be removed if necessary without 
having to cut the pipework. 

7.  Install an approved weatherproof electrical 

general power outlet (GPO). This can be 
installed inside the box in accordance with 
AS/NZS 3000 electrical wiring rules. 

8.  Commission the water heater in 

accordance with the commissioning 
checklist supplied with the Rinnai 
INFINITY. 

9.  Attach the warning label supplied with the 

recess box to the front panel of the water 
heater. 

10.  Install the recess box cover by ensuring 

the four locking clips have securely 
engaged. 

 
Also secure the cover to the body of the 
recess box with the two screws provided 
in the kit—these come screwed  into the 
middle of the recess box. These are needed, 
especially in windy areas, to prevent the 
cover being blown off. 

11.  Use an approved solution to seal the box, 

cavity and any penetrations, including any 
pipe and electrical penetrations.

Содержание Composite Recess Box

Страница 1: ...e Approved Document External Moisture E2 The recess box installation can be compared to the detail required to install a meter box Territorial authorities may have their own additional requirements regarding this type of installation If in any doubt over compliance with building codes it is advisable they are consulted prior to installation ...

Страница 2: ... New Zealand Limited 105 Pavilion Drive Mangere Auckland PO Box 53177 Auckland Airport Auckland 2150 Phone 09 257 3800 Email info rinnai co nz Web www rinnai co nz www youtube com rinnainz www facebook com rinnainz Important Installers please note These instructions are for the tradespeople installing the recess box and continuous flow water heater If you are not installing the water heater please...

Страница 3: ...ts About the composite recess box 4 Dimension information 5 Recessed and brick installations 6 Semi recessed frame installations 8 Installing the water heater 10 Flue terminal clearance positioning diagram 11 ...

Страница 4: ...ighting the main clearances on p 11 Position Some considerations when installing a Rinnai recess box with an external continuous flow water heater Operating noise A Rinnai INFINITY gas water heater operates at a slightly louder level than a unit installed on an outside wall Please keep this in mind when positioning near a bedroom as the operating noise could affect some people Hot water outlets In...

Страница 5: ...stallation guide 10847 D 04 18 5 Dimension information mm 1078 1023 1086 69 118 446 12 440 Approximate depth with cover on 240 mm Depth 100 Approx 1 m 130 Centre of noggin 130 Centre of noggin Width 390 Height 1030 Depth 160 ...

Страница 6: ...e methods described below Secured externally Secured using brick ties Secured internally through the rear wall Secured internally through a side wall Secured externally Secured to the wall surface via the eight screw holes provided in the flange of the recess box using suitable fasteners Secured using brick ties Secure a brick tie to the side walls of the recess box with pop rivets or screws As th...

Страница 7: ... may require packing to prevent distortion of the recess box At least two fasteners should be used through each side wall approximately 125 mm from the inside of the top and horizontal faces of the recess box Installing to rendered surfaces Use spacers not provided to install the recess box leaving sufficient clearance for rendering When the render is applied ensure that the gap provided by the st...

Страница 8: ...ented so the sealing flange is against the wall surface and the drainage slots are in the lower most position The recess box can be secured using any of the methods described below Secured externally Secured using brick ties Secured internally through the rear wall Secured internally through a side wall Secured externally Use the 8 x 100 mm screws supplied to secure the flashing collar and recess ...

Страница 9: ...opening Secure the recess box through the rear using suitable fasteners 125 mm 125 mm 110 40 90 130 130 Secured internally side wall Secure the recess box into a solid fixture such as timber studs through the side walls using suitable fasteners At least two fasteners should be used through each side wall approximately 125 mm from the inside of the top and horizontal faces of the recess box ...

Страница 10: ...o the box Remove the blanking plugs from the holes that will be used and replace with the grommets supplied otherwise use the supplied grommets for other drilled holes The pipe entry points are elevated to prevent water ingress 6 Complete the gas and water connections It is recommended that flexible gas and water connectors are used to make the final connections this allows the water heater to be ...

Страница 11: ...ter inside a recess box the clearances excluding F will be the same as the dimensions taken from the flue outlet of the water heater G Dim INFINITY A Series VT and XR models A Min 300 mm B Min 300 mm C Min 1 5 m D Min 500 mm E Min 300 mm F Min 300 mm G Min 300 mm Clearance below eaves balconies and other projections for all models is 300 mm Rinnai recommend 1 5 m to give enough clearance for the p...

Страница 12: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz 10847 D 04 18 ...

Отзывы: