10

RCE-470/670 TRE

CUSTOMER OPERATING INSTRUCTIONS

INSTALLATION

Check room size and ventilation

This heater must not be installed in a room 
smaller than:

The AVENGER 25Plus must not be in a room
smaller than 62.5 m

3

.

The CAPELLA 18Plus must not be in a room
smaller than 45.0 m

3

.

Fixed ventilation must conform to local regulations.

Number and position of vents is for illustrative purposes only. For more information on ventilation, 
please refer to our Rinnai Web Site www.rinnai.com.au

DO NOT install in a bedroom or bathroom.

The bayonet plug on the factory fitted flexible hose simply plugs into your bayonet fitting. The control 
panel is located on the top of the appliance, basic controls are also located on the remote control.

For the AVENGER - H x W x D must equal or exceed 62.5 m

3

 . 

For example: if room size is L 5.2 m x W 5.0 m x H 2.4 m the volume will be 62.4 m

3

For the CAPELLA - H x W x D must equal or exceed 45.0 m

3

 . 

For example: if room size is L 4.5 m x W 4.2 m x H 2.4 m the volume will be 45.4 m

3

This heater must not be installed where 
curtains or other combustible materials could 
come into contact with it. In some cases 
curtains may need restraining.

Other clearances are shown in the diagram. 

This heater is not designed to be built in.

Width

Depth

Height

HEAT

ER

ON/ OFF

SET

50mm

750mm

50mm

50mm

50mm

T h e   a b o v e   d i a g r a m   s h o w s   t h e   c l e a r a n c e s   r e q u i r e d

a r o u n d   t h i s   h e a t e r   w h i l s t   i n   o p e r a t i o n .

Содержание Avenger 25 Plus

Страница 1: ...cturer s Installation Instructions Local Gas Fitting Regulations Municipal Building Codes AG601 AS5601 2000 Gas Installations AS NZS 3000 Wiring Rules Any other relevant Statutory Regulation This appl...

Страница 2: ...t also comply with the instructions supplied by Rinnai The appliance must be serviced by an authorised person No Parts or functions should be modified or permanently removed from the heater Please not...

Страница 3: ...RUCTIONS 10 HOW TO OPERATE THE HEATER 11 ADJUSTING TEMPERATURES 12 HEATER MODES FUNCTIONS 13 SETTING HEATER MODES 14 SETTING CLOCK 15 PROGRAMMING THE ON OFF TIMERS 16 OPERATING THE ON OFF TIMERS 17 PR...

Страница 4: ...Rinnai Australia 1 RCE 470 670 TRE STANDBY ON BUTTON ABOUT YOUR NEW AVENGER CAPELLA Plus...

Страница 5: ...Rinnai Australia 2 RCE 470 670 TRE STA N D B Y ON S TA N D B Y ON button CONTROL PANEL LAYOUT...

Страница 6: ...Rinnai Australia 3 RCE 470 670 TRE STANDBY BUTTON Timer mode STANDBY button will cancel any future timer operations these will have to be reset manually REMOTE CONTROL...

Страница 7: ...indicator will flash The filters should be vacuumed at regular intervals to avoid unnecessary strain on the appliance REMOTE CONTROL For the convenience of operating the heater between STANDBY or ON...

Страница 8: ...g pool toilet or sauna The appliance must not be used to heat any of these areas 6 DO NOT connect to an LPG Gas cyclinder indoors 7 This appliance must not be installed where curtains or other combust...

Страница 9: ...intended for use by young children or infirm persons without supervision Young children should be supervised to ensure they DO NOT play with the appliance Do not allow children or elderly persons to s...

Страница 10: ...se Keep heater away from flammable materials Combustible materials must not be placed where the heater could ignite them Do not spray aerosols near this heater while it is in use Most aerosols contain...

Страница 11: ...er while it is in operation or while the fans are still cycling Unplugging the heater will cause the timer and clock to stop however programmed ON OFF times will remain in the memory Do not place cont...

Страница 12: ...air in the room contains cooking vapours or cigarette smoke To avoid this possibility it is recommended that a mat be placed in front of the appliance extending at least 750 mm in front of it During...

Страница 13: ...ur bayonet fitting The control panel is located on the top of the appliance basic controls are also located on the remote control For the AVENGER H x W x D must equal or exceed 62 5 m3 For example if...

Страница 14: ...ter to STANDBY To return the heater to STANDBY while it is in operation press the STANDBY ON button once STANDBY ON button twice to restart heaters STANDBY ON button The STANDBY and ON buttons located...

Страница 15: ...Rinnai Australia 12 RCE 470 670 TRE STANDBY ON STANDBY ON STANDBY ON STANDBY ON STANDBY ON Button STANDBY ON button STANDBY ON button once ADJUSTING TEMPERATURES...

Страница 16: ...at the room using Gas convection or Gas and Electric convection Electric convection is used only when the room is cold and or when the heat load is high Gas combustion in this mode is continuous and w...

Страница 17: ...Rinnai Australia 14 RCE 470 670 TRE SETTING HEATER MODES...

Страница 18: ...Rinnai Australia 15 RCE 470 670 TRE STANDBY ON STANDBY ON STANDBY ON STANDBY ON STANDBY ON STANDBY ON STANDBY ON STANDBY ON Button STANDBY condition STANDBY ON Button STANDBY SETTING CLOCK...

Страница 19: ...NDBY ON STANDBY ON STANDBY ON Button With the heater in the STANDBY condition press the SET button until PROGRAM is shown in the control panel display and the hour digits are flashing Here we will lea...

Страница 20: ...r to the programmed starting time of a Timer This function is called Pre heat since it ensures the room reaches the desired temperature by the time the Timer programs On time The room temperature is s...

Страница 21: ...luminated Green steady when this is the case Press the OVERRIDE button once to turn heater on the heater Mode and Temperature controls are now available Return to Set Timer Programs STANDBY ON OVERRID...

Страница 22: ...ter turn it off and then follow the ignition procedure OXYGEN DEPLETION SAFETY DEVICE If the oxygen level in the room drops below a pre set limit this device cuts the gas supply to the heater If the o...

Страница 23: ...ome on before cleaning filters Do not use the heater with the filter warning lamp on this may cause it to overheat REMOVING FILTERS Filters require cleaning at least once a week during the heating sea...

Страница 24: ...be serviced every 2 years If the power supply cord gas supply hose or any other component of the heater is damaged they must be replaced by Rinnai or a suitably qualified person Any service or repair...

Страница 25: ...ls to ignite on initial attempt try 3 to 4 more times however if the heater ignition continues to be unsuccessful arrange a service call ERROR CODES STANDBY ON switch ON Overheat Switch the Heater to...

Страница 26: ...Rinnai Australia 23 RCE 470 670 TRE DIMENSIONS SPECIFICATIONS 202 203 610 570 243 Dimensions in mm...

Страница 27: ...TE CONTROL RECEIVER TR TRANSFORMER OH TH OVER HEAT THERMISTOR POV MODULATING SOLENOID VALVE ODS OXYGEN DEPLETION SENSOR SV1 2 MAIN SOLENOID VALVE 1 2 CFM CONVECTION FAN MOTOR HFM HEATER FAN MOTOR CODE...

Страница 28: ...New South Wales Queensland Western Australia Tel 1300 366 388 Tel 02 9609 2600 Tel 1300 363 123 Tel 08 9479 9479 Fax 03 9271 6611 Fax 02 9729 0467 Fax 07 3209 4722 Fax 08 9277 2531 Emergency Hot Wate...

Отзывы: