Rinnai Australia
10
RCE-470/670 TRE
CUSTOMER OPERATING INSTRUCTIONS
INSTALLATION
Check room size and ventilation
This heater must not be installed in a room
smaller than:
The AVENGER 25Plus must not be in a room
smaller than 62.5 m
3
.
The CAPELLA 18Plus must not be in a room
smaller than 45.0 m
3
.
Fixed ventilation must conform to local regulations.
Number and position of vents is for illustrative purposes only. For more information on ventilation,
please refer to our Rinnai Web Site www.rinnai.com.au
DO NOT install in a bedroom or bathroom.
The bayonet plug on the factory fitted flexible hose simply plugs into your bayonet fitting. The control
panel is located on the top of the appliance, basic controls are also located on the remote control.
For the AVENGER - H x W x D must equal or exceed 62.5 m
3
.
For example: if room size is L 5.2 m x W 5.0 m x H 2.4 m the volume will be 62.4 m
3
For the CAPELLA - H x W x D must equal or exceed 45.0 m
3
.
For example: if room size is L 4.5 m x W 4.2 m x H 2.4 m the volume will be 45.4 m
3
This heater must not be installed where
curtains or other combustible materials could
come into contact with it. In some cases
curtains may need restraining.
Other clearances are shown in the diagram.
This heater is not designed to be built in.
Width
Depth
Height
HEAT
ER
ON/ OFF
SET
50mm
750mm
50mm
50mm
50mm
T h e a b o v e d i a g r a m s h o w s t h e c l e a r a n c e s r e q u i r e d
a r o u n d t h i s h e a t e r w h i l s t i n o p e r a t i o n .
Содержание Avenger 25 Plus
Страница 4: ...Rinnai Australia 1 RCE 470 670 TRE STANDBY ON BUTTON ABOUT YOUR NEW AVENGER CAPELLA Plus...
Страница 5: ...Rinnai Australia 2 RCE 470 670 TRE STA N D B Y ON S TA N D B Y ON button CONTROL PANEL LAYOUT...
Страница 17: ...Rinnai Australia 14 RCE 470 670 TRE SETTING HEATER MODES...
Страница 26: ...Rinnai Australia 23 RCE 470 670 TRE DIMENSIONS SPECIFICATIONS 202 203 610 570 243 Dimensions in mm...