TO TURN ON YOUR HEATER
NOTE
BEFORE PROCEEDING ENSURE THE GAS AND ELECTRICITY ARE TURNED ON.
When the heater is in the OFF condition (the power supply connected and switched ON but the
heater turned OFF) the Red Power Indicator
b
will be extinguished. This is normal.
Access the 'Push Button Control Panel'
1
. This is located on the
front of the heater at the lower right hand corner.
Step 1. Press ON / OFF button
a
once. You will be able to
hear the ignition sparking.
Step 2.
The sparking ignition stops when the pilot flame has
been established. The main burner then ignites off the
pilot flame and is automatically preset to Stage 5 -
High Flame.
NOTE
FLAME HEIGHT AND FAN SPEED
The relationship between the flame height and fan
speed are preset and can not be independently
adjusted.
Flame Height
1
2
3
4
5
Fan Speed (2
speed only
Low
Low
Low
High
High
TO TURN OFF YOUR HEATER
To turn the heater ‘OFF’ press the Standby / ON button
A
once, when the heater is in the OFF state the Red
Power Indicator will be extinguished.
INTERRUPTION TO ELECTRICITY OR GAS SUPPLY DURING OPERATION
Interruption to the power or gas supply will turn your heater OFF, upon resumption of the services the appliance will
need to be restarted. This is a safety feature designed to ensure that un-attended starts do not occur after power
or gas interruptions.
RESTART PROCEDURE AFTER INTERRUPTION TO ELECTRICITY SUPPLY
To restart your heater once power has been restored follow the steps for "To Turn ON Your Heater" as above.
FULL CONTROL AND PARTIAL CONTROL
Full operation of the heater is only possible by using the remote control. In the event of a misplaced or broken
remote control or if the batteries for the remote control are flat, this appliance may still be operated in a limited
capacity by using the power ON/OFF button
A
of the 'Push Button Control Panel'
1
located at the lower right
corner of the appliance outer frame.
The heater will automatically modulate between flame settings to maintain the default set temperature of 22°C.
No additional control of the flame or heat output is possible via the appliance ON/OFF button.
b a