ABNORMAL FLAME PATTERN
Each Rinnai Gas Fire has a distinct flame pattern. The flame should look the same every time you operate your
heater, after an initial warm up period of approximately 15 minutes.
Abnormal flame performance and/or pattern can indicate a problem with your heater, such as blocked gas injectors,
incorrectly installed / inadequate flue system or the Ceramic logs / stones and/or burner media may have shifted
from when the heater was first installed.
There are some warning signs that could indicate a problem. If any of the signs below occur, please contact Rinnai.
Key signs of abnormal flame performance:
•
Appliance turns ‘OFF’ soon after start up and does not relight.
•
Flame appears overly orange-yellow.
•
Flame appears either very short or very long.
•
Flame only burns part way across the burner.
•
Severe soot building up on the inside of the glass or on logs.
•
Continuous unusual smell from the appliance.
•
Continued difficulty or delay in establishing a flame.
NOTE
Be advised that appliances incorporating a live fuel effect, and designed to operate with luminous
flames, may exhibit slight carbon deposition. This is normal operation.
CR2450 BUTTON BATTERIES
CAUTION
KEEP BATTERIES OUT OF REACH OF CHILDREN
• Swallowing button batteries may lead to serious injury in as little as 2 hours or death, due to
chemical burns and potential perforation of the oesophagus.
• If you suspect your child has swallowed or inserted a button battery immediately call the 24hr
Poisons Information Centre on 13 11 26 for fast, expert advice.
• Regularly examine the remote controller and make sure the battery compartment is completely
secured.
• Any used button batteries
MUST BE
disposed of immediately and safely.
IMPORTANT
The remote control uses 2x CR2450 3V lithium batteries. When the battery change indicator
is displayed, Rinnai recommends fresh replacement batteries will need to be made available, as
continued full functionality of the heater is dependent on the use of the remote control.