background image

Table of Contents 

Introduction................................................................................... 4

Installation .................................................................................. 5

Using PeripheralVision® to Configure the Router................... 7

IP Router Page ............................................................................. 8

Passwords .................................................................................... 9

Routing Table Page...................................................................... 9

Broadcast Forward Page............................................................ 11

PeripheralVision® Licensing....................................................... 12

Token Ring Speed Settings ..................................................... 13

Safety and Location Advice..................................................... 14

Technical Specification............................................................ 15

Troubleshooting Guide ............................................................ 16

RD2004112901 | Eth_Tring_Rout_Man.doc

 

- 3 - 

 

Содержание Ethernet-Token Ring

Страница 1: ...Ethernet Token Ring Network Router User Manual RD2004112901 Eth_Tring_Rout_Man doc 1 ...

Страница 2: ...on of Ringdale UK Limited DISCLAIMER Ringdale UK Ltd reserves the right to revise this publication and to make changes from time to time to the contents hereof without obligation to notify any person or organization of such revision or changes Ringdale UK Ltd has endeavored to ensure that the information in this publication is correct but will not accept liability for any error or omission TRADEMA...

Страница 3: ...onfigure the Router 7 IP Router Page 8 Passwords 9 Routing Table Page 9 Broadcast Forward Page 11 PeripheralVision Licensing 12 Token Ring Speed Settings 13 Safety and Location Advice 14 Technical Specification 15 Troubleshooting Guide 16 RD2004112901 Eth_Tring_Rout_Man doc 3 ...

Страница 4: ...B connector or type 3 cable on an RJ 45 connector The router has the ability to automatically sense which Token Ring connection is used as well as the Token Ring speed at either 4MHz or 16MHz The router is designed to easily mount into an industry standard 19 inch rack system for convenience The router is configured and managed remotely using Ringdale s PeripheralVision network management software...

Страница 5: ...will blink when the router transmits data to the Ethernet network The Yellow Link LED indicates that the Ethernet network connection is functioning Connecting the Router to the Token Ring Network Insert either a Type 3 cable with an RJ 45 connector or a Type 1 cable with a 9 way DB connector from the Token Ring network into the RJ 45 or DB 9 port respectively marked Token Ring Network 2 The router...

Страница 6: ...r cable to the mains electricity supply Switch the router on using the Power switch on the rear panel Important Note If there is a delay in connecting the router to the Token Ring network after power up it may be necessary to restart the router in order to make a good link to the Token Ring network When using PeripheralVision you should see two 2 routers each representing a different side of the r...

Страница 7: ...works 3 Using the Locate NPMP discovery tool in PeripheralVision enter the default set IP address 11 22 33 44 The router will appear on the network map it will be an icon similar to the example on the left 4 Left click twice on the icon to open the property pages of the device The default displayed page will be the Name page This is shown below 5 In the Icon Title field enter a name for the router...

Страница 8: ... Network 1 Default Gateway IP Address Enter here the IP address of another router This will allow packets for unrecognized IP addresses to be redirected to that router DNS Name Server Address Enter here the IP Address of the DNS server if required optional Local IP Address Enter here the router s IP address for the Token ring Network 2 this will be the gateway for the Ethernet network Local IP Sub...

Страница 9: ...e the configuration will now be restricted to those who have the Password Back to TOC Routing Table Page 7 It is now necessary to tell the router where to route the IP packets This is done by creating a Routing Table Use the arrows to scroll the pages and select the Routing Table page Make sure that the whole IP range is passed over to the other network Any packets that are not in this range will ...

Страница 10: ...sses are on the Ethernet network enter the address assigned to the Local IP Address field previously for the Token Ring network use the address assigned to the first IP Address field H Hops Enter here the number of hops across networks or subnets that are necessary to route the packets to the required IP Address IF Interface Enter here the port through which the IP packets will be routed either th...

Страница 11: ...twork the router s Local IP Address will need to be entered as that PC s gateway for a device on the Token Ring network the router s first IP Address will need to be the gateway 9 To ensure the router is set up correctly ping a device on the Token Ring network from a device on the Ethernet network Then ping a device on the Ethernet Network from the Token Ring network Back to TOC Broadcast Forward ...

Страница 12: ... click the required address to select it and then click Delete The IP address will be removed Click Apply to save any changes you make Back to TOC PeripheralVision Licensing PeripheralVision software comes licensed for 30 days after which a full license may be purchased to continue access to all the facilities of the program This does not affect your ability to use PeripheralVision to configure th...

Страница 13: ... are located on the circuit board and are easily identified by a red jumper The layout is shown in the diagram below The red jumper will be over the Auto pin only enabling the router to select 16MHz or 4MHz as required To set one speed only remove the jumper and replace it over the Auto pin and the pin of the speed you wish to set as shown in the diagrams below After the setting has been selected ...

Страница 14: ...elds produced by electrical devices Provided with a properly grounded wall outlet Do not attempt to modify or use the supplied AC power cord if it is not the exact type required Ensure that the system is disconnected from its power source and from all telecommunications links networks or modem lines whenever the chassis cover is to be removed Do not operate the system with the cover removed Do not...

Страница 15: ...28K X 8 static RAM Token Ring Connectors Type 1 DB9 Type 3 RJ 45 Network 2 Ethernet Connector RJ 45 type Network 1 Communication Speed 4 16 Mbit s Token Ring 10 Mbits Ethernet Operating Environment Temperature 10 C to 35 C 50 F to 95 F Relative Humidity 15 to 70 Part No 00 03 2328 2450 Note specifications are subject to change without notice Back to TOC RD2004112901 Eth_Tring_Rout_Man doc 15 ...

Страница 16: ...ter Fuse defect Replace fuse LEDs do not light up blink No cable inserted Connect to hubs and Router Router not powered up Check power supply for Router Wrong cable type Verify cable selection Bad cable Replace cable Delay in connecting Router to Token Ring device Power off and power on again Back to TOC RD2004112901 Eth_Tring_Rout_Man doc 16 ...

Страница 17: ...44 0 1444 870228 Ringdale GmbH Cochemer Straße 12 14 D 68309 Mannheim Germany Freephone 0800 8251880 Tel 49 0 621 7186 0 Fax 49 0 621 7186 20 Ringdale Inc 101 Halmar Cove Georgetown Texas 78628 USA Toll free 888 288 9080 Tel 1 512 288 9080 Fax 1 512 288 7210 Website http www ringdale com RD2004112901 Eth_Tring_Rout_Man doc 17 ...

Отзывы: