9
Battery Chemistry Selection
The multi chemistry function allows you to set the optimum charging profile to suit each batteries
chemistry type: Gel, AGM, Lead Acid (WET) and calcium. This ensures correct and thorough charging
and maximises battery performance and battery life
Gel
Designed for Gel batteries and applies a maximum charge of 14.1v (RSCPR824: 28.2v)
AGM
Designed for AGM batteries and applies a maximum charge of 14.4v (RSCPR824: 28.8v)
Lead Acid (Wet)
Bulk and absorption 14.7v (RSCPR824: 29.4v), recondition up to 16v (RSCPR824: 32v)
Calcium
Bulk and absorption 14.7v (RSCPR824: 29.4v), Equalisation and Recondition up to 16v
(RSCPR824: 32v)
Set battery chemistry type (RSCPR7, RSCPR10 & RSCPR15)
1.
With the SmartChargePro connected to the AC mains supply press the ‘Select’ button, all LED’s will
light up, wait for the LED’s to turn off
2.
Press the ‘Mode’ button repeatedly until the correct battery type is selected
Set battery chemistry type (RSCPR25, RSCPR35, RSCPR50 & RSCPR824)
1.
With the SmartChargePro connected to the AC mains supply and ‘ON/OFF’ switch ON press the
‘Battery type selection switch’ (the LCD display will flash the present setting)
2.
Press the ‘Battery type selection switch’ repeatedly until the correct battery type is selected
(Previous setting will display if nothing selected)
Manual Reconditioning
(RSCPR25, RSCPR35, RSCPR50 and RSCPR824)
Reconditioning can restore a battery from a deeply discharged state by equalising the battery cells
to improve battery performance allowing the battery to operate at full capacity. It is advised that
periodically a manual Recondition charge should be carried out to optimise a batteries health
and performance.
It is advised that for batteries where the electrolyte level needs checking and maintaining the manual
reconditioning process takes place with the battery removed from the vehicle.
Press the Manual Recondition button. The SmartChargePro will remain in this mode for 4 hours.
During Reconditioning the LCD will display rapid horizontal lines. On completion of the Recondition
stage the charger will then start a normal charging cycle.