background image

8

LCD Display 

(RSCPR25,  RSCPR35, RSCPR50 and RSCPR824)

The LCD display on the SmartChargePro can display the following information:

 Battery voltage (V)

 Charging current applied (A)

 Battery type: Gel, AGM, Wet (lead acid) and Calcium.

 Battery charging  / Charged icon

 Recondition / equalisation modes

 Power supply mode (battery support unit)

 ‘Err’ – Short circuit or reverse polarity (reverse connection of clips)

Battery Fault codes

 ‘F01’ – Bulk charging has timed out. Charging stopped after 22 hours

   The charger has entered recondition mode 3 times and has timed out

Battery cannot be charged

CHARGING LED:

 Blue LED illuminates and flashes during charging process

FULLY CHARGED LED:

 Green LED illuminates solid when fully charged

LED Indicators 

(RSCPR7, RSCPR10 and RSCPR15)

LED Indicators 

(RSCPR25, RSCPR35, RSCPR50 and RSCPR824)

Desulphation Soft Start

Bulk

Absorption / 

Equalisation

Analyse

Recondition

Float

Power  

(Red LED)

Charging  

(Blue LED)

(Fast Flash)

(Slow Flash)

(Solid)

(Solid)

(Slow Flash)

Full  

(Green LED)

(Slow Flash)

(Slow Flash)

(Slow Flash)

(Solid)

Desulphation Soft Start

Bulk

Absorption / 

Equalisation

Analyse

Recondition

Float

Bulk Charge  

(Blue LED)

(Fast Flash)

(Slow Flash)

(Solid)

(Slow Flash)

Absorption  

(Blue LED)

(Solid)

(Slow Flash)

(Slow Flash)

Full Charged  

(Green LED)

(Solid)

Power   

(Red LED)

Solid: 

Power On

Flashing:

 ‘Err’ or ‘F01’ fault codes

Содержание RSCPR10

Страница 1: ...PR10 12v 10A SmartChargePro15 RSCPR15 12v 15A SmartChargePro25 RSCPR25 12v 2 6 12 25A SmartChargePro35 RSCPR35 12v 2 8 16 35A SmartChargePro50 RSCPR50 12v 2 6 12 25 50A SmartChargePro824 RSCPR824 24v 2 4 6 8A Instructions Retain these instructions for future reference 12v 24v ...

Страница 2: ... only a single battery at any one time Charging rechargeable lead acid wet Gel AGM and calcium batteries with 6 cells The Ring SmartChargePro automatically adjusts the charge rate applied as the battery charges When the battery is fully charged the charging process stops As the battery naturally discharges further charging is applied until the battery is again fully charged This is an ongoing proc...

Страница 3: ... indicator 4 Select switch selects between Power Supply Gel AGM lead acid wet and calcium batteries 5 Power supply 6 Gel battery setting 7 AGM battery setting 8 Lead Acid Wet battery selection 9 Calcium battery setting 1 2 3 4 5 6 7 8 9 202 61 108 SmartChargePRO10 222 61 108 SmartChargePRO15 182 61 108 SmartChargePRO7 ...

Страница 4: ...ate select switch 4 Battery type selection switch 5 Manual recondition function 6 AC Power LED indicator 7 Bulk charge stage LED indicator 8 Absorption stage LED indicator 9 Fully Charged LED indicator 10 ON OFF switch 11 Protective rubber end caps 168 81 210 SmartChargePRO25 168 81 250 SmartChargePRO35 168 81 270 SmartChargePRO50 190 81 168 SmartChargePRO824 ...

Страница 5: ... connected safely and correctly to the battery 2 Connect the SmartChargePro AC power lead to the AC power supply RSCPR7 RSCPR10 and RSCPR15 the AC power LED indicator lights up RSCPR25 RSCPR35 RSCPR50 and RSCPR824 turn on ON OFF switch the AC power LED lights up 3 When charging is complete the Fully Charged LED lights up 4 The SmartChargePro can be left safely connected to a battery for an indefin...

Страница 6: ...ion Additional stage for calcium batteries removes acid stratification 6 Battery test The SmartCharge conducts an automatic discharge test If further charging is required the battery recondition function is automatically selected If fully charged the battery goes into the float stage 7 Recondition An additional automatic charging stage to recover deeply discharged batteries 8 Float The float stage...

Страница 7: ...il the required charge rate is set Part Number Voltage Charge Rates Maximum Recommended Battery RSCPR7 12v 7A 50 140Ah RSCPR10 12v 10A 70 200Ah RSCPR15 12v 15A 85 300Ah RSCPR25 12v 2 6 12 25A 14 500Ah RSCPR35 12v 2 8 16 35A 14 700Ah RSCPR50 12v 2 6 12 25 50A 14 1000Ah RSCPR824 24v 2 4 6 8A 14 160Ah Charge Rate Battery Size AH CCA 2amp 14 40 80 240 4amp 30 80 180 480 6amp 40 120 240 720 7amp 50 140...

Страница 8: ...ttery cannot be charged CHARGING LED Blue LED illuminates and flashes during charging process FULLY CHARGED LED Green LED illuminates solid when fully charged LED Indicators RSCPR7 RSCPR10 and RSCPR15 LED Indicators RSCPR25 RSCPR35 RSCPR50 and RSCPR824 Desulphation Soft Start Bulk Absorption Equalisation Analyse Recondition Float Power Red LED Charging Blue LED Fast Flash Slow Flash Solid Solid Sl...

Страница 9: ...RSCPR35 RSCPR50 RSCPR824 1 With the SmartChargePro connected to the AC mains supply and ON OFF switch ON press the Battery type selection switch the LCD display will flash the present setting 2 Press the Battery type selection switch repeatedly until the correct battery type is selected Previous setting will display if nothing selected Manual Reconditioning RSCPR25 RSCPR35 RSCPR50 and RSCPR824 Rec...

Страница 10: ...l on the temperature sensor onto the negative battery post Cable length 1 8m WARNING Ensure the cable is secured away from moving parts Power Supply Battery support unit This sets the SmartChargePro in power supply mode giving a constant of voltage of 13 8v RSCPR824 27 6v Ideal for maintaining a constant battery voltage level when appliances or vehicle diagnostic equipment are connected and drawin...

Страница 11: ...l Ideal if your battery is in a permanent or not easy to access location The remote control includes a bi colour LED indicator that illuminates in different ways to indicate different stages of charging To install the remote control Insert the data plug into the data socket on the rear face of the SmartChargePro The removable mounting bracket can be fixed to a surface to create a mounting station ...

Страница 12: ...ilated area Ensure there is at least 10cm clearance from the end plates to allow adequate ventilation for the cooling fan Do not cover the charger and keep clean and free of dust For permanent connection it is advised to connect to the battery terminals with a ring terminal connection Ensure all sensor wires that run parallel to both positive and negative cables are also connected Include an in li...

Страница 13: ...he battery in vehicle RSCPR25 RSCPR35 RSCPR50 and RSCPR824 Requires a battery in vehicle What happens if I have an appliance connected to the battery while charging Powering an appliance while charging will impact on the SmartChargePro s ability to accurately measure the charge being applied For optimum charging it is recommended to charge the battery without an appliance connected Power Supply mo...

Страница 14: ...d wet Gel AGM Calcium Lead acid wet Gel AGM Calcium Lead acid wet Gel AGM Calcium Lead acid wet Gel AGM Calcium Lead acid wet Gel AGM Calcium Battery Capacity 50 140Ah 70 200Ah 85 300Ah 14 500Ah 14 700Ah 14 1000Ah 14 160Ah Dimensions 182L x 108B x 61H 202L x 108B x 61H 252L x 108B x 61H 248L x 176B x 86H 328L x 176B x 86H 328L x 176B x 86H 248L x 176B x 86H Weight 0 97 1 15 1 5 2 5 3 56 3 56 2 32 ...

Отзывы: