Rincent ND Technologies
Minidyn User Manual
Page 21
Here the parameter commonly used in different standard.
Parameters
France
NFP 94-117-1
NFP 94-117-2
Germany
ZTVE-StB 94
Plate radius
300 mm
150 mm
Poisson coefficient
0,25
0,30
Form factor
4,00
3,81
Resulting equation
E = 3,13 * K
(converted or a 300 mm
plate radius)
E = 3,18 * K
2.4
Correlation algorithms
2.4.1
Linear correlation
Linear correlation is used primarily to obtain an equivalent modulus on a restrained
modulus value range and for a given platform.
∗
Coefficient K is typically comprised between 1 and 2.
Coefficient K have to be determined by the user. A common procedure is to perform
correlation trial test to determine the K coefficient that is adapted to a particular ground
material thickness and treatment.
Figure 15 : Correlation test between
E
lwd
and
E
V2
.
The linear correlation is often used in large platform or road site where material and
thickness does not change.