6. 

Ask profession person to install, check and maintain the machine. 

 

Please correctly understand the contents of this manual to ensure safety, and ask those 

professional people with safety knowledge and technique to operate the machine. 

 

Danger! Please follow the rules below in case of electric shock: 

      

Any contact of electric parts may cause fatal electric shock or burnt. 

1. 

Don’t touch any electric parts. 

2. Ask professional person to connect the machine and workpiece to the ground. 

3. Cut off the power box before the installation or checking, and restart after 5 minutes. For the 

capacitance is chargeable, please ensure it has no voltage before restart even if the power source is 

cut off. 

4. Do not use cable without enough section or with worn-out cover or broken conductor. 

5. Do ensure insulation at the cable joint parts. 

6. Do not use the machine when the housing is off. 

7. Do not use broken or wet insulation gloves. 

8. Use safety net when work at high position. 

9. 

Check and maintain regularly, don’t use it until the broken parts are fixed well. 

10

Cut off all the input power when not use. 

11

Follow  the  national  or  local  related  standard  and  regulations  when  using  the  AC/DC  machine  at 

narrow or high position. 

 

Danger! Please use preventive measures to avoid gas and fumes. 

Gas and fumes are harmful to health. 

It may cause choke when operate in narrow space. 

 

1. In case of accidents like gas poisoning or choke, please use suggested exhaust equipment and 

breathe preventive facilities. 

2.  In case of hurt and poisoning by gas and other powder, please use suggested part exhaust 

equipment and breathe preventive facilities. 

3.  When operated on trunks, boilers, cabins etc.,the CO2 and argon gas will stay in the bottom. Please 

replace gas sufficiently and use gas respire facilities in case of oxygen shortage. 

4. 

Please accept the supervisor’s check when operate in narrow space, and ensure enough gas supply 

and use breathe preventive facilities. 

5.  Do not weld in degrease, washing and spray space. 

Содержание TIG 315PAC/DC

Страница 1: ...TIG 315P AC DC WELDING MACHINE USER MANUAL...

Страница 2: ...t or property lose if it is not followed The words after this sign means there is potential risk which may cause equipment fault or break if it is not followed Version Version YF TAE 0089 A1 Released...

Страница 3: ...MACHINE DESCRIPTION 9 TECHNICAL PARAMETERS TABLE 10 OPERATION INSTRUCTION 14 MAINTENANCE 16 NOTES BEFORE CHECKING 17 NOTES OR PREVENTIVE MEASURES 17 QUESTIONS TO BE RUN INTO DURING WELDING 19 TROUBLES...

Страница 4: ...bility of dangerous situation and may cause badly hurt if not avoid It can also refer to property loss Notes This means it may cause body hurt if not avoid Please refer to the related description when...

Страница 5: ...or wet insulation gloves 8 Use safety net when work at high position 9 Check and maintain regularly don t use it until the broken parts are fixed well 10 Cut off all the input power when not use 11 F...

Страница 6: ...not weld those facilities with gas pipe or airtight slot 8 Put fire extinguisher around the welding area in case of fire Notes Please wear protective appliance to avoid arc spark residue and noise Ar...

Страница 7: ...ole or the wire shooted out may stab your eyes and face 2 When feeding the wire manually or press the torch do not put the torch end near to your eyes face and other naked parts Notes Follow the below...

Страница 8: ...iphone f Equipments for adjustment and measurement g Anti disturb capability of other used equipments Users should ensure these equipments and the environment are compatible and this may need extra pr...

Страница 9: ...ics is that DC function can be used to weld stainless steel alloyed steel carbon steel copper and other color metals and AC function can be used to weld aluminum and aluminum alloy materials such as w...

Страница 10: ...load voltage V 62 65 68 Rated output voltage V 22 TIG 29 6 MMA Pulse duty cycle 10 90 Post time S 1 10 Pulse frequency LF Hz 0 5 15 Pulse frequency MF Hz 15 450 Basic value current A 12 300 Arc initia...

Страница 11: ...quency change over switch 2T 4T Repeat switch Peak welding current adjustment Base current adjustment Crater current adjustment Post time adjustment Down slope adjustment Clean pulse width adjustment...

Страница 12: ...e hoop or other things to fasten lest argon leaks out and air get in 3 Make sure the earth end of power interface has been reliably and independently grounded 4 Put the loop cable fastening plug to th...

Страница 13: ...13 Installation diagram TIG mode Installation diagram MMA mode Argon meter Power supply Argon cylinder Earth clamp TIG torch Workpiece Power supply Earth clamp Workpiece Electrode holder...

Страница 14: ...t value of the current according to the thickness of the work piece when the pulse switch is on low position there is no current 9 Press the control knob of the torch the e electromagnetic valve begin...

Страница 15: ...itive and negative current 3 Same as the above10 12 instruction items Note 1 When the current is heavy please choose larger pulse duty 2 AC argon arc is hard to initiate please set the current value t...

Страница 16: ...l components of inner machine 3 Check inter circuit of welding machine regularly and make sure the cable Circuit is connected correctly and connectors are connected tightly especially insert connector...

Страница 17: ...entilated Our welding machine is powerful machine when it is being operated it generated high currents and natural wind cannot satisfy with machine cool demands So there is a fan inside the machine fo...

Страница 18: ...derstand this situation and take preventive measures 4 There is a grounding screw behind welding machine with a grounding marker on it Before operation welding crust must be grounded reliably with cab...

Страница 19: ...end of the tungsten electrode to taper If tungsten electrode is not grinded that will be difficult to strike arc and cause unstable arc When power voltage departs from the rated value it will make th...

Страница 20: ...here is no sound of HF arc striking wiping arc welding can not strike arc 1 Check if all kinds of cables of inter machine are poor contact 2 There is some fault in control panel find out reason and co...

Страница 21: ...riking power source which is near the VH 07 insert of fan then open machine a If abnormal indicator is still lit some of MOSFET of MOS board is damaged find out and replace it with same model b If abn...

Отзывы: