TROUBLESHOOTING AND FAULT FINDING 

 

 

    

Notes: The following operations must be performed by qualified electricians with valid 

certifications. Before maintenance,please contact with us for professional suggestion. 

 

fault symptom and solutions: 

 

 

Faults 

Resolvable Methods 

 
 
 
 

 

Fan does not Work and 

numerical screen is not 

indicating, there is no welding 

output 

 

1.  Make sure power switch is closed 

2.  Make sure electrify wire net of output cable can supply power 

3.  Some of heat-variable resistors (four) of power panel is damaged, 

when it happen ,general DC24V  relay is open or connectors is poor 

contact 

4.  Power panel (bottom board ) is damaged, DC537V or DC587V 

voltage can be output 

5.  Auxiliary power of control panel is in fault 

6.  The transformer is damaged 

 

 

Fan works, abnormal indicator 

is not lit ,there is no sound of 

HF arc-striking, wiping arc 

welding can not strike arc 

 

1.  Check if all kinds of cables of inter-machine are poor contact 

2.  There is  some fault in  control  panel,  find  out  reason  and  connect 

with seller 

3.  Control cable of torch is broken 

 

Abnormal   Indicator    is   not lit 

,sound of HF  arc-striking can 

be  heard,  there  is  no  welding 

output 

 

1.  Torch cable is broken 

2.  Grounding cable is broken or not connected to welding piece 

3.  Positive electrode terminal or torch electrify terminal is loosed from 

inter-machine 

 
 

 

Abnormal   indicator    is   not 

lit ,there is no sound of HF arc-

striking ,wipe 

welding can strike arc. 

 

1.  Primary  cable  of  arc-striking  transformer  is  not  connected  to arc-

striking panel reliably, tighten it again 

2.  Arc-striking  tip  is  oxidized  or  too  far,  give  a  good  polish  to  it  or 

change it is about 1 mm between arc-striking tip 

3.  Switch (sticking/argon-arc welding) is damaged, replace it 

4.  Some  of  HF  arc-striking  circuit  components  is  damage,  find  out 

and replace it 

Содержание TIG 315PAC/DC

Страница 1: ...TIG 315P AC DC WELDING MACHINE USER MANUAL...

Страница 2: ...t or property lose if it is not followed The words after this sign means there is potential risk which may cause equipment fault or break if it is not followed Version Version YF TAE 0089 A1 Released...

Страница 3: ...MACHINE DESCRIPTION 9 TECHNICAL PARAMETERS TABLE 10 OPERATION INSTRUCTION 14 MAINTENANCE 16 NOTES BEFORE CHECKING 17 NOTES OR PREVENTIVE MEASURES 17 QUESTIONS TO BE RUN INTO DURING WELDING 19 TROUBLES...

Страница 4: ...bility of dangerous situation and may cause badly hurt if not avoid It can also refer to property loss Notes This means it may cause body hurt if not avoid Please refer to the related description when...

Страница 5: ...or wet insulation gloves 8 Use safety net when work at high position 9 Check and maintain regularly don t use it until the broken parts are fixed well 10 Cut off all the input power when not use 11 F...

Страница 6: ...not weld those facilities with gas pipe or airtight slot 8 Put fire extinguisher around the welding area in case of fire Notes Please wear protective appliance to avoid arc spark residue and noise Ar...

Страница 7: ...ole or the wire shooted out may stab your eyes and face 2 When feeding the wire manually or press the torch do not put the torch end near to your eyes face and other naked parts Notes Follow the below...

Страница 8: ...iphone f Equipments for adjustment and measurement g Anti disturb capability of other used equipments Users should ensure these equipments and the environment are compatible and this may need extra pr...

Страница 9: ...ics is that DC function can be used to weld stainless steel alloyed steel carbon steel copper and other color metals and AC function can be used to weld aluminum and aluminum alloy materials such as w...

Страница 10: ...load voltage V 62 65 68 Rated output voltage V 22 TIG 29 6 MMA Pulse duty cycle 10 90 Post time S 1 10 Pulse frequency LF Hz 0 5 15 Pulse frequency MF Hz 15 450 Basic value current A 12 300 Arc initia...

Страница 11: ...quency change over switch 2T 4T Repeat switch Peak welding current adjustment Base current adjustment Crater current adjustment Post time adjustment Down slope adjustment Clean pulse width adjustment...

Страница 12: ...e hoop or other things to fasten lest argon leaks out and air get in 3 Make sure the earth end of power interface has been reliably and independently grounded 4 Put the loop cable fastening plug to th...

Страница 13: ...13 Installation diagram TIG mode Installation diagram MMA mode Argon meter Power supply Argon cylinder Earth clamp TIG torch Workpiece Power supply Earth clamp Workpiece Electrode holder...

Страница 14: ...t value of the current according to the thickness of the work piece when the pulse switch is on low position there is no current 9 Press the control knob of the torch the e electromagnetic valve begin...

Страница 15: ...itive and negative current 3 Same as the above10 12 instruction items Note 1 When the current is heavy please choose larger pulse duty 2 AC argon arc is hard to initiate please set the current value t...

Страница 16: ...l components of inner machine 3 Check inter circuit of welding machine regularly and make sure the cable Circuit is connected correctly and connectors are connected tightly especially insert connector...

Страница 17: ...entilated Our welding machine is powerful machine when it is being operated it generated high currents and natural wind cannot satisfy with machine cool demands So there is a fan inside the machine fo...

Страница 18: ...derstand this situation and take preventive measures 4 There is a grounding screw behind welding machine with a grounding marker on it Before operation welding crust must be grounded reliably with cab...

Страница 19: ...end of the tungsten electrode to taper If tungsten electrode is not grinded that will be difficult to strike arc and cause unstable arc When power voltage departs from the rated value it will make th...

Страница 20: ...here is no sound of HF arc striking wiping arc welding can not strike arc 1 Check if all kinds of cables of inter machine are poor contact 2 There is some fault in control panel find out reason and co...

Страница 21: ...riking power source which is near the VH 07 insert of fan then open machine a If abnormal indicator is still lit some of MOSFET of MOS board is damaged find out and replace it with same model b If abn...

Отзывы: