background image

62-450

www.rikontools.com

62-450M1

Air Filtration System

450 CFM

Operator’s Manual

Serial Number: _________________________     Date of purchase: _________________________

For technical support or parts questions, email [email protected] or call toll free at (877)884-5167

Record the serial number and date of purchase in your manual for future reference.

The serial number can be found on the specification label on the rear of your machine.

Содержание 62-450

Страница 1: ...__ Date of purchase _________________________ For technical support or parts questions email techsupport rikontools com or call toll free at 877 884 5167 Record the serial number and date of purchase in your manual for future reference The serial number can be found on the specification label on the rear of your machine ...

Страница 2: ...r Wheel Material Steel Blower Wheel Type Squirrel Cage Sound Ratings L M H 3Ft 57 64 68dB Cabinet Size LxWxH 19 75 x 16 75 x 10 502 x 425 x 254 mm Net Weight 28 5 lbs 13 kg Specifications 2 Safety Warnings 2 6 Air Filtration Safety Rules 7 UnpackingandContents 7 GettingtoKnowYourAirFiltrationSystem 8 Assembly 8 10 Operation 10 11 Maintenance 12 13 Troubleshooting 14 Wiring Diagram 15 Notes 15 Part...

Страница 3: ...e your careful attention and understanding The symbol warnings do not by themselves eliminate the danger The instructions and warnings they give are no substitutes for proper accident prevention measures THIS SYMBOL DESIGNATES THAT THIS TOOL IS LISTED BY THE INTERTEK TESTING SERVICES TO UNITED STATES AND CANADIAN STANDARDS SAFETY SYMBOLS ...

Страница 4: ...to ground the tool and provide protection against accidental electric shock DO NOT remove the 3rd prong See Grounding Instructions on page 6 4 AVOID A DANGEROUS WORKING ENVIRONMENT DO NOT use electrical tools in a damp environment or expose them to rain 5 DO NOT use electrical tools in the presence of flammable liquids or gasses 6 ALWAYS keep the work area clean well lit and organized DO NOT work ...

Страница 5: ...thing the dust and avoid prolonged contact with dust Allowing dust to get into your mouth or eyes or lay on your skin may promote absorption of harmful material Always use properly fitting NIOSH OSHA approved respiratory protection appropriate for the dust exposure and wash exposed areas with soap and water 26 USE A PROPER EXTENSION CORD IN GOOD CONDITION When using an extension cord be sure to us...

Страница 6: ... to a 2 contact ungrounded receptacle The adapter has a rigid lug extending from it that MUST be connected to a permanent earth ground such as a properly grounded receptacle box THIS ADAPTER IS PROHIBITED IN CANADA EXTENSION CORDS Keep the extension cord clear of the working area Position the cord so that it will not get caught on lumber tools or other obstructions while you are working with a pow...

Страница 7: ...ards smoke toxic fumes spray paint or flammable liquids 9 Do not use without filters in place 10 Never duct a machine directly into the air filtration system 11 Do not leave the System running unattended 12 Always make sure the power switch is in the OFF position prior to plugging in the machine 13 Always disconnect unplug and make sure the power switch is in the OFF position when doing any assemb...

Страница 8: ...NOT turn your machine ON if any of these items are missing You may cause injury to yourself or damage to the machine 2 Report any shipping damage to your local distributor Take photographs for any possible insurance claims 3 Clean all rust protected surfaces Do not use gasoline paint thinner mineral spirits etc These may damage painted surfaces 4 Set packing material and shipping carton to the sid...

Страница 9: ...talling the Air Filtration System in a ceiling location test run the unit to make sure that it runs properly Hanger Installation Fig 04 and Fig 05 1 Thread the locknuts A almost all the way up the hangers B 2 Thread a hanger into each of the four mounting holes C on the top of the air filter cabinet 3 Tighten each locknut against the cabinet top A securing the hanger in place Hold the hanger so th...

Страница 10: ...s Cycles de Filtrage Ciclos de Filtro 20 x20 x8 room 5 6 5 8 times hr 20 x20 x8 salle 5 6 5 8 fois h Habitación 20 x20 x8 5 6 5 8 veces h OFF ARRÊT APAGAR Model 62 450 Air Filtration 450 EN MARCHE ENCENDER VITESSE VELOCIDAD ON SPEED 4H 2H 1H HIGH MID LOW HAUTE MÉDIUM BAS MEDIO BAJO ALTO FUSE FUSIBLE 5 AMPS C M Y CM MY CY CMY K 62 450 Control Panel EFS China pdf 1 3 17 2020 8 49 21 AM The air filte...

Страница 11: ... TIME button C on the remote control Fig 09 to start the timer 2 Press the TIME button C on the remote control again to set the length of operation The LEDs D Fig 08 on the control panel indicate the amount of time selected 1 hour 2 hours 4 hours Press a fouth time to clear the timer NOTE The unit will shut off automatically after the selected time interval elapses When you choose clear the timer ...

Страница 12: ...d Clogged filters will reduce the amount of air circulating through the filter 1 Lift up the two clips Fig 10 A on the left and right of the cabinet and remove the outer filter Fig 11 B from the cabinet housing 2 Pull the inner filter Fig 11 C out of the cabinet 3 Install a new inner filter Make sure the filter bags point inwards into the cabinet NOTE The inner filter can be blown out with air or ...

Страница 13: ...ll a new CR2025 battery positive side up according to the picture shown inside of the battery cover 4 Close the battery compartment Fig 12 Fig 13 A Battery Compartment MAINTENANCE Chemical Burn Hazard Keep batteries away from children This product contains a lithium button coin cell battery If a new or used lithium button coin cell battery is swallowed or enters the body it can cause severe intern...

Страница 14: ...l panel circuit board has failed 1 Have a qualified electrican check circuit for proper voltage 2 Replace motor capacitor 3 Inspect or replace control panel circuit board System has vibration or is noisy 1 Motor or cabinet part is loose 2 Motor fan is rubbing cover 3 Motor bearings are loud 4 Air filters rattle 5 Impeller fan is loose unbalanced or damaged 6 Motor base is loose in the cabinet 1 In...

Страница 15: ...machine must be grounded Replacement of the power supply cable should only be done by a qualified electrician READ ELECTRICAL SAFETY ON PAGES 5 6 Use this section to record maintenance service and any calls to Technical Support NOTES ...

Страница 16: ... 34 2 3 30 11 4 5 13 3 12 14 9 8 7 6 10 31 6 8 9 4 5 20 7 8 9 18 29 28 22 23 33 空气净化器 060A0308T1261 Sheet YKQ05 35 NOTE Please reference the Manufacturer s Part Number when calling for Replacement Parts For Parts under Warranty the Serial Number of your machine is required ...

Страница 17: ...N MOTOR BLOWER ASSEMBLY 40 38 33 36 43 37 39 41 42 Sheet AC060A091000A 开关盒组件 60Hz CONTROL PANEL ASSEMBLY 17 NOTE Please reference the Manufacturer s Part Number when calling for Replacement Parts For Parts under Warranty the Serial Number of your machine is required ...

Страница 18: ...ft Turbine Cap Left Turbine Wheel Blower Housing Hex socket button head screw M6X10 Spring washer Motor 120v Right Turbine Wheel Right Turbine Cap 4 1 8 8 8 7 7 7 13 1 1 4 4 4 4 4 4 4 1 1 1 10 10 1 1 2 2 6 4 1 1 1 5 1 1 1 1 1 1 1 1 1 1 6 2 1 1 1 3 4 1 1 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 ...

Страница 19: ...pply to accessory items such as blades drill bits sanding discs grinding wheels belts guide bearings and other related items Seller shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our products T To take advantage of this warranty proof of purchase documentation must be provided which has the...

Страница 20: ...www rikontools com 62 450M1 62 450 For more information 16 Progress Road Billerica MA 01821 877 884 5167 978 528 5380 techsupport rikontools com ...

Отзывы: