3-2.Name of each part and functions
① Oxygen sensor
: Galvanic type sensor to detect oxygen content.
② Sensor holder
: This is a retainer to hold the oxygen sensor
(equipped filter inside).
③ Sensor lead wires
: Lead wires for oxygen signal outputs.
④ Terminal strip 1
: Relayed terminal for sensor lead wires and external cable.
⑤ Cable gland
: Entrance to lead the cable (φ8 - φ11mm) from outside.
⑥ Hinge
: Hinge for front door.
⑦ Lock
: Lock for front door.
⑧ Mounting hole
: Mounting hole to fix this unit on the wall surface.
⑨ Terminal strip 2
: Relayed terminal for input/output signal use to the signal converter.
⑩ 4mA adjusting hole
: VR hole to adjust 4 mA of 4-20mA output(factory set)
⑪ SPAN adjusting hole
: VR hole to adjust SPAN
⑫ ZERO adjusting hole
: VR hole to adjust ZERO
⑬ Front door
: Front door for the unit
⑭ Signal converter
: Circuit unit to convert the sensor output into 4-20mA
⑮ Protective earth bolt
: Bolt for protective grounding.
3-3.
System composition
(1) Intrinsically safe system
Detector
head
Zener barrier
Indicator
/alarm
unit
Hazardous area
Non-hazardous area
In-between head and zener barrier :
CVVS 1.25mm
2
2-core or equivalent (max 250m)
However, that of head and indicator/alarm unit :
CVVS 1.25mm
2
2-core or equivalent (max 2km)
4-20mA
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪ ⑫
⑬
⑭
⑮
Содержание GD-F4A-SC-A
Страница 1: ...Oxygen Gas Detector Head GD F4A SC A Operating Manual PT2 152 PT2E 2510...
Страница 6: ......
Страница 11: ......
Страница 19: ......
Страница 24: ......
Страница 26: ...Manual Log Rev Amendment Issue data 0 First issue 2018 2 9...