Prior to set up

Floor bearing capacity

Ensure that the substructure is capable of bearing the weight of the stove prior 

to set-up.

Note

No modifications may be made to the firing installation. This also leads to loss 

of warranty and guarantee.

Floor protection

A base is required (glass, sheet steel or ceramic) if the floor is combustible 

(wood, carpet, etc.).

Flue pipe connection

 

Q

Flue pipes pose a particular source of hazard regarding gas leaks and 

fire. Get the advice of an authorised specialist company for the layout and 

assembly.

 

Q

Please observe the corresponding installation guidelines for walls panelled 

with wood when connecting your flue pipes to the stove,

 

Q

Observe the formation of flue gas (atmospheric inversion) and draughts 

when the weather is unfavourable.

 

Q

Infeed of too little combustion air can lead to smoke in the rooms or to flue 

gas leaks. Hazardous deposits in the stove and chimney may also occur.

 

Q

If flue gas escapes, let the fire burn out and check whether all the air inlet 

openings are free and the flue gas pipes and the stove pipe are clean. If in 

doubt notify the master chimney sweep since draught malfunctions may be 

connected to your chimney.

 

Q

Push the embers together to form a firebed when you add new fuel (logs).

 

Q

Only use suitable tools from our range of accessories when handling embers 

and make sure that no embers fall out of the combustion chamber onto 

inflammable material.

 

Q

Use the heat-resistant gloves supplied to open the doors of your stove.

Stoves type 1 (BA 1):

 

Q

These may only be operated with the combustion chamber door closed. 

 

Q

The combustion chamber door may only be opened to add fuel  and must 

then be closed again otherwise other firing installations connected to the 

chimney may be endangered.

 

Q

The combustion chamber door is to be kept closed when the stove is not 

in operation.

 

Q

Fouling of the chimney i.e. deposits of highly inflammable materials such as 

soot and tar and subsequently fire in the chimney may occur if wet fuel is 

used and operation is damped too much.

 

Q

If this occurs phone the fire brigade and get yourself and other residents 

out of harm’s way.

Note

The size of the combustion chamber door makes it necessary, particularly 

with post-heating when ablaze, not to open the door too abruptly to prevent 

the tips of the flames reaching out.

Note

on ROOM-AIR DEPENDENT and

ROOM-AIR INDEPENDENT OPERATION:

Your stove has been tested as a room-air dependent stove according to EN 

13240 and does not conform in Germany to the requirements for room-

air independent operation. In combination with room-air installations (e.g. 

controlled ventilation and venting systems (extractors etc.) it must be ensured 

that the stove and the room air system are monitored and safeguarded 

mutually (e.g. via a differential pressure controller etc.). The combustion air 

infeed of approx. 40 m3/h must be ensured. Please observe the respective 

local regulations and rules in consultation with your master chimney sweep

Содержание TURA

Страница 1: ...Operating Manual TURA TURA...

Страница 2: ...unts with nominal heat output 10 Clean combustion 10 4 INSTALLING THE STOVE 11 General information 11 Connection to the chimney 11 Connecting to a steel chimney 11 Combustion air 11 Feeding in externa...

Страница 3: ...18 Ampty the ash drawer 18 Cleaning the door glass 18 Cleaning the convection air openings 18 Cleaning the flame temperature sensor 18 Checking door seal 18 Checking chimneay connection 18 11 PROBLEMS...

Страница 4: ...loded diagram 5 4 5 2 4 9 4 8 5 0 4 7 5 1 5 3 4 2 4 1 4 1 4 3 4 0 4 6 4 6 4 4 4 5 3 15 16 17 12 11 10 14 3 5 1 2 3 9 3 7 3 8 3 6 4 5 7 6 1 9 8 3 2 2 6 2 8 2 9 2 3 2 5 3 0 2 7 2 1 3 1 3 3 2 4 2 1 2 0 2...

Страница 5: ...2 82 7 9 80 7 7 83 8 5 113 8 4 10 7 10 8 8 9 9 0 9 1 9 2 10 3 10 2 10 6 10 4 10 5 8 6 8 7 8 8 9 7 9 8 9 4 9 6 9 9 10 0 9 5 10 1 9 3 111 112 7 1 6 4 6 3 5 9 6 2 6 1 6 9 7 0 5 8 6 7 6 8 5 7 6 7 6 8 6 6...

Страница 6: ...058 cover secondary air 55 Z34991 soapstone cover 56 Z34990 soapstone inlay 57 Z34989 soapstone side right 58 Z34988 soapstone side left 59 B17052 rear wall manual 60 B17012 rear wall Rikatonic 61 Z10...

Страница 7: ...of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to submit it to the authorities or the chimney sweep on request Note Please...

Страница 8: ...thing or equipment e g heat resistant gloves or means of operation operating handle Q Make your children aware of this particular danger and keep them away from the stove during heating Q Only burn ap...

Страница 9: ...stion chamber onto inflammable material Q Use the heat resistant gloves supplied to open the doors of your stove Stoves type 1 BA 1 Q These may only be operated with the combustion chamber door closed...

Страница 10: ...els of resin and burns off faster as do all softwoods and tends to spray sparks wood type fuel value kWh m3 fuel value kWh kg maple 1900 4 1 birch 1900 4 3 beech 2100 4 2 oak 2100 4 2 alder 1500 4 1 a...

Страница 11: ...e pipe connection to the chimney has to be air tight Combustion air Every combustion process requires oxygen from the surrounding air This so called combustion air is removed from the living are in th...

Страница 12: ...during any conversion work Select soft bases to prevent scratches to your living space furniture and stove panels Retrofitting to flue pipe connection rear Lift the stone cover off Now lift off the t...

Страница 13: ...off control of the heating up starts The heating up phase takes approx 60 min depending on the temperature and fill amount This time is required to obtain a suitable bed of embers The display changing...

Страница 14: ...grate can be closed for further wood addition after the heating up Note If there are any problems with lighting due to the chimney draught then always leave the riddle grate open Power failure In the...

Страница 15: ...ocess can no longer be ensured adding wood is not permitted The stove must be heated up again The display lamp is constantly GREEN The stove is in normal operation The display lamp is constantly YELLO...

Страница 16: ...ly see Cleaning and Maintenance Contact RIKA customer service XX X The display lamp flashes 2x RED and 1x YELLOW The magnetic switch is defective or jammed The air flaps are jammed Check whether an ob...

Страница 17: ...d in Item 3 Please proceed in the same way for every further addition of wood Note If a lot of smoke develops when wood is placed on a low firebed an explosive gas air mixture may arise and cause a de...

Страница 18: ...ith water Note Ash may contain embers only place ash in sheet steel containers Ampty the ash drawer Empty the ash drawer regularly The ash drawer is simply pulled forward with the combustion chamber d...

Страница 19: ...t Possible solution s Q Wait to end of burning in phase and vent sufficiently Q Suction off any dust deposits from the convection air openings at regular intervals Problem 3 Flue gas discharge when wo...

Страница 20: ......

Страница 21: ...urchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts af...

Страница 22: ...Ofentechnik GmbH 4563 Micheldorf Austria M llerviertel 20 Telefon 43 7582 686 41 Fax DW 43 E Mail verkauf rika at RIKA AT Technical and design changes as well as typesetting and printing errors reserv...

Отзывы: