15
EN
14
7. STATUS DISPLAYS
Note
Notify customer service immediately if malfunction messages occur in succession.
LED display
Meaning
Action to be taken
The display lamp
flashes intermittently
RED
The stove has just been switched on and the air
flaps start the reference run
The control system starts a reference run again
after a brief power failure
The stove cannot heat up until the display lamp
stops flashing
The display lamp is
constantly
RED
The combustion chamber is cold and the stove is
in neutral
The combustion chamber temperature has fallen
below the temperature specified for adding wood
The stove is ready to heat up
Optimum control process can no longer be
ensured, adding wood is not permitted. The
stove must be heated up again
The display lamp is
constantly
GREEN
The stove is in normal operation
The display lamp is
constantly
YELLOW
The stove is in ECO normal operation
The display lamp
flashes regularly
RED
The temperature specified for adding wood was not
reached
Open the combustion chamber door and add a
log or let the stove go out
The display lamp
flashes regularly
GREEN
After the opening of the combustion chamber door,
the stove tries to light the wood added
The riddle grate should be open if the draught
is low when adding wood; but closed for high
draught
The display lamp
flashes regularly
YELLOW
The ECO key was pressed after adding wood.
The magnetic switch sequence was initiated
See “Actions to be taken – flashes regularly
green”
See “Complete closing of the air flaps”