RIKA PARO Скачать руководство пользователя страница 9

|9

EN

8

Note: Please consider the powdercoated parts can differ slightly in colour and colour effects though they are elaborated in high quality�

Nr.

Art.Nr.

Description

108

Z36993

Front stone white

Z36842

Soapstone front

Z37005

Front sandstone

B18259

Front black with angle

109

N112020

Grommet

110

N111730

Grommet

111

Z37051

Spacer

112

N112490

Levelling screw black

113

B16574

Touch-display plug-in

114

N112030

Screw motor, stepless

115

L03302

Support for motor

116

N111909

Hexagon socket screw

117

B18232

Motor plate assy

118

Z11915

Lock ring conveyer screw

119

N112499

Grub screw

120

Z35182

Friction bearing Di16

121

B17235

Auger

122

Z35183

Friction bearing Di10

123

B16053

Sensor tube

124

B16114

Temperature sensor

125

L01441

Pressure bracket

126

B17166

Ceramic ignition

127

Z36290

Seal for ignition

128

N111933

Flange nut

130

B18306

Cable run

131

B18152

Airbox with intake pipe socket

132

N111641

Self-tapping screw

133

N110833

Self-tapping screw

134

Z37002

Spacer plate

135

B16951

Induced draft fan housing

136

N111581

Induced draft fan motor

137

N111817

Air regulator motor

138

B16030

Additional motherboard for motor, incl. 
cable

139

B16672

Add. Board

140

B16561

Mainboard USB11

141

N111604

Fuse 2,5 A

142

N112016

Power switch

143

B18167

Extension of actuator

146

Z36710

Fluegas flap

147

N111631

Round sealing cord grey Ø6mm

148

Z36966

Shaft of fluegas flap

149

N103981

Circlips

150

N112413

Hexagonal screw

151

Z36709

Frame of fluegas flap

152

B18607

Axis fluegas flap

153

B18497

Shaft sealing

154

L03296

Bearing plate

155

N106472

Self-tapping screw

156

L03297

Retaining plate

157

N112416

Torsion spring

160

N111842

Hexagon socket M03x10

161

L02310

Guard plate

Nr.

Art.Nr.

Description

162

N111732

Magnetic switch top part

163

L03300

Holder plate magnetic switch 

164

N111950

Hexagonal screw M05x10

165

B17925

Flap handle

166

L03298

Lever fluegas flap

167

N109233

Hexagonal nut

168

N112417

Pressure spring

170

LB00740

Magnet plate

171

N111733

Solenoid switch bottom part

172

Z37666

Electromagnet

173

N109390

Hexagonal screw

174

L01445

Switch spacer

177

B18169

Convection cover assy

178

N112127

Locking bolt

179

Z36001

Snap spring

180

B18226

Cover RAO

181

B18227

Cover AH

182

Z36994

Container lid

B18168

Container lid assy

183

N111731

Container seal

184

L03306

Hinge guidance

185

Z36996

Hinge pin

186

Z36997

Bushing

187

L03308

Hinge holder

188

N109985

Allen screw

189

N111801

Grub screw

190

Z36995

Hinge pin top

191

L03307

Hinge part

192

Z34489

Spacer

193

N107150

Washer

194

N112415

Hexagonal screw

195

L01446

Lock washer

196

N110461

Double ball catch

197

N111459

Allen screw

198

L01502

Lock washer

199

N110606

Self-tapping screw

B18179

Wiring harness

Z35018

Cable for touch-screen 1,25 m

Z34841

Cable for additional motherboard

E16474

Sealing kit

PARO MULTIAIR

200

L03368

Fan holder

201

L03369

Cleaning opening

202

N112419

Wing screw

203

B18256

Side cladding panel black MultiAir

204

N112492

Knurled screw

205

L03405

Cover for air outlet

206

B16155

Induced draft fan housing

207

N112000

Fan motor

B17101

Convection fan assy

208

N110573

Hexagonal screw

Содержание PARO

Страница 1: ...PARO PARO MULTIAIR Operating Manual ...

Страница 2: ...LLING THE STOVE 14 General information 14 Connection to the chimney 14 Connecting to a steel chimney 14 Combustion air 14 Feeding in external combustion air 14 4 TECHNOLOGY AND SAFETY FUNCTIONS 15 Operating comfort 15 Top efficiency lowest emissions 15 Low temperature shutdown 15 Electrical excess current protection 15 Flue gas flap 15 Automatic cleaning cycle 15 Component monitoring 15 Auger moto...

Страница 3: ...ning the pellet container 22 Cleaning flue pipes PARO and PARO MultiAir 22 Cleaning the flue gas channels 23 Checking door seal 23 Bearings 23 12 PROBLEMS POSSIBLE SOLUTIONS 24 Problem 1 24 Problem 2 24 Problem 3 24 13 INSTRUCTIONS FOR COMMISSIONING PROTOCOL 25 15 COMFORT OPTIONS 27 Room sensor Radio room sensor 27 GSM Control 27 Interface for various options 27 External room thermostat 27 Externa...

Страница 4: ... 9 12 11 4 21 5 6 19 20 20 16 16 15 15 3 22 22 23 23 24 24 24 8 1 2 30 15 33 32 28 25 26 27 35 29 43 10 41 39 45 44 42 40 49 56 94 93 96 94 93 63 90 89 89 88 88 64 92 91 71 83 68 69 70 84 82 87 85 86 48 60 47 61 62 46 51 50 52 66 65 98 97 54 53 55 80 74 81 73 75 78 77 79 76 95 67 72 99 58 59 57 ...

Страница 5: ... 5 EN 4 102 103 104 103 100 105 101 110 106 111 112 108 107 109 110 200 201 202 203 109 205 204 ...

Страница 6: ...122 121 120 117 131 134 135 136 132 133 118 119 114 115 116 126 123 124 125 140 139 138 141 142 143 113 137 128 130 127 206 207 208 ...

Страница 7: ... 154 155 156 155 172 157 166 164 167 168 163 164 162 161 160 174 171 161 160 165 170 179 183 198 196 199 174 171 161 160 178 180 181 184 191 192 192 193 193 194 182 190 185 185 186 186 187 187 188 188 195 196 197 197 162 161 160 189 189 177 178 ...

Страница 8: ... black D12 51 B18157 Convection cover assy 52 N112411 Flange nut 53 N112414 Wing nut Nr Art Nr Description 54 B17282 Cleaning cover assy 55 N103066 Round sealing strip black D06 56 N112253 Grub screw 57 Z36840 Baffle plate top 58 Z36841 Baffle plate bottom 59 Z36838 Baffle plate rear 60 Z36984 Firebrick lining rear right 61 Z36986 Firebrick lining right rear 62 Z36987 Firebrick lining right front ...

Страница 9: ... of fluegas flap 152 B18607 Axis fluegas flap 153 B18497 Shaft sealing 154 L03296 Bearing plate 155 N106472 Self tapping screw 156 L03297 Retaining plate 157 N112416 Torsion spring 160 N111842 Hexagon socket M03x10 161 L02310 Guard plate Nr Art Nr Description 162 N111732 Magnetic switch top part 163 L03300 Holder plate magnetic switch 164 N111950 Hexagonal screw M05x10 165 B17925 Flap handle 166 L...

Страница 10: ...t g s 5 3 5 8 Exhaust temperature C 170 3 152 5 Chimney draft requirement Pa 3 12 The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to submit it to the authorities or the chimney sweep on request Note Please observe the national and European stand...

Страница 11: ... 9 11 3 CO emission on 13 O2 mg mN 3 79 5 580 Dust emission mg mN 3 19 5 25 5 Exhaust g s 5 3 5 8 Exhaust temperature C 170 3 152 5 Chimney draft requirement Pa 3 12 The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to submit it to the authorities...

Страница 12: ...h the embers together to form a firebed when you add new fuel logs Q Q Placing non heat resistant objects on the stove or near it is prohibited Q Q Do not place clothing on the stove to dry Q Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q Q When your stove is burning the use of highly inflammable and explosive materials in the same or adjacent rooms...

Страница 13: ... deflections as small as possible Note Please pay attention to the national and country specific building and fire regulations when connecting the convection air pipes Installation and assembly must be performed by a trained specialist only Stoves type 1 BA 1 Q Q These may only be operated with the combustion chamber door closed Q Q Suitable for multiple occupancy note the different country regula...

Страница 14: ... 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspection and cleaning must be present The flue pipe connection to the chimney has to be air tight Combustion air Every combustion process requires oxygen from the surrounding air This so called combustion air is removed from the living are in the case of individual...

Страница 15: ... If the stove is heated according to its function in the combined operation a significant improvement can be achieved due to the higher temperatures in log wood mode Low temperature shutdown The unit switches off if the stove cools below a minimum temperature This switch off may occur if pellet ignition is delayed Electrical excess current protection The stove has a main fuse at the rear to protec...

Страница 16: ...th a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list of monitored fuel manufacturers Note Only burn pellets that have been inspected according to ENplus A1 Using poor quality or prohibited pellet fuel will have a negative effect on the function of your pellet stove and can al...

Страница 17: ...articularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all softwoods and tends to spray sparks Wood type Calorific value kWh m3 Calorific value kWh kg Maple 1900 4 1 Birch 1900 4 3 Beech 2100 4 2 Oak 2100 4 2 Alder 1500 4 1 Ash 2100 4 2 Spruce 1700 4 4 Larch 1700 4 4 Poplar 1200 4 1 Robinia 2100 4 1 Fi...

Страница 18: ...ar care of your fingers and any panels and stove attachments Select soft bases to prevent scratches to your living space furniture and stove panels Dismantling stone Open the container lid to the stop it remains open in this position Open the door of the combustion chamber Open the 4 hex head bolts and remove the two stone holders Tip the stone slightly forwards and lift it out of the floor bracin...

Страница 19: ...illing operation In order to reduce the discharge of fluegas when refilling logs there is a easy refilling operation available unhide additional functions hide additional functions Open the fluegas flap Wait about 3 seconds before you open the combustion chamber door to refuel After closing the combustion chamber door turn the wrench clockwise to close the fluegasflap Tip If the flue gas flap is o...

Страница 20: ...AGRAM PELLET LOG OPERATION X X X door open ON OFF split logs recognised X no split logs recognised X X Burn off Control mode Start Ignition Stove OFF Split log check Split log mode Split log check Split log mode ...

Страница 21: ... especially with low output This is a natural process and does not constitute a defect The glass can be cleaned best with a moist cloth Stubborn dirt can be removed with a special cleaner available from your stove dealer Usual cleaners containing acid or solvents can be too harsh and damage the glass Cleaning of painted surfaces Wipe of the painted surfaces with a damp cloth do not scrub Do not us...

Страница 22: ...or to the start of the heating season to prevent excess odour Note To prevent your stove from overheating of the internal components do never cover the convection fins Combustion air intake If necessary please also clean the air intake with a hoover Note Only when the stove is cold You could vacuum out embers FIRE RISK Cleaning the pellet container Do not refill the completely empty container imme...

Страница 23: ... operation of your combination stove replace the defect porous frayed seals after cleaning and maintenance Cleaning the flue gas channels annually Remove the flue pipes Inspect and clean chimney connection Brush off any soot and dust deposits in the fire and in the flue pipes and vacuum Note Accumulated fly ash in the flue gas channels may impair the performance of the stove and pose a safety risk...

Страница 24: ... s pellet log operation Q Q Burning in phase taking into service Q Q Stove has accumulated dust and or dirt Possible solutions pellet log operation Q Q Wait to end of burning in phase and vent sufficiently Q Q Suction off any dust deposits from the convection air openings at regular intervals Problem 3 Flue gas discharge when wood is added and during heating phase Cause s pellet log operation Q Q ...

Страница 25: ...ns These are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in the putting into operation It is very important that the operator understands the stove properly and is prepared to assume responsibility for the basic tasks required for operational safety In p...

Страница 26: ...aged Serial number Operating instructions Software version Warranty documents Touchdisplay version Door opener Electrical periphery Connection socket earthed GSM modem present Room thermostat present Function checked Check of system components Combustion chamber door seal checked Ease of movement burnback flap checked combi Ease of movement flue gas flap checked combi Exhaust line chimney Diameter...

Страница 27: ... COMFORT OPTIONS Room sensor Radio room sensor This option permits control of your stove via room temperature You can set both the room temperature and the heating times required A room temperature selected by you is observed during the heating times Please see the operating instructions for the option room sensor and wireless room sensor for more detailed information GSM Control Your stove can al...

Страница 28: ...y valid one Technical and design changes as well as typesetting and printing errors reserved 2019 RIKA Innovative Ofentechnik GmbH Z37061_Paro_EN 7 01 2020 RIKA Innovative Ofentechnik GmbH Müllerviertel 20 4563 Micheldorf AUSTRIA Tel 43 0 7582 686 41 Fax 43 E Mail verkauf rika at www rika at ...