![RIKA PARO Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/rika/paro/paro_operating-manual_1461340027.webp)
|27
EN
26
14. WARRANTY
These warranty conditions are only valid for the following countries: Austria, Germany and Switzerland� Separate conditions imposed by the
importer apply for all other countries� In case of doubt as well as missing or incorrect translations, the German version is the only valid one�
For the purpose of timely damage limitation the claimant is required to file the warranty claim with the RIKA dealer in writing, submitting the
invoice and stating the purchase date, model name, serial number and reason for complaint�
Warranty
5 years on the welded stove body� This exclusively applies to defects in materials and workmanship as well as free replacement� Labour and
travel times are not included in the manufacturer’s warranty�
Only original parts supplied by the manufacturer should be used� Loss of warranty on non-observance!
The precondition for the warranty is that the stove has been installed and commissioned properly according to the User and installation
manuals valid at the time of purchase� Connection must be performed by a specialist for such stoves�
Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant�
Wear parts and parts affected by fire are excluded, such as glass, coating, surface coatings (e.g. handles, panels), seals, fire trough, grates,
draught plates, deflector plates, combustion chamber liners (e.g. fireclay), ceramics, natural stone, thermo stone, ignition elements,
sensors, combustion chamber sensors and temperature controller.
Also excluded from this warranty are all damages arising from non-observance of the manufacturer’s operating instructions of the unit,
or damage caused by overheating, use of nonapproved fuels, unauthorised tampering with the appliance or the flue gas pipe, electrical
excess voltage, an incorrect, insufficient or excessive flue draught, condensation, non-performance or deficient maintenance and cleaning,
nonobservance of the relevant and applicable building regulations, incorrect operation by the user or third parties, as well as any transport
and handling damage�
This manufacturer‘s warranty does not affect the statutory warranty provisions.
03�04�2018
15. COMFORT OPTIONS
Room sensor, Radio room sensor
This option permits control of your stove via room temperature� You
can set both the room temperature and the heating times required�
A room temperature selected by you is observed during the heating
times�
Please see the operating instructions for the option room sensor and
wireless room sensor for more detailed information�
GSM Control
Your stove can also be controlled via a mobile phone as an additional
option�
Please see the operating instructions for the telephone option –
GSM for more detailed information�
Interface for various options
for various options
The ROOM SENSOR, the WIRELESS ROOM SENSOR and the PHONE
OPTION – GSM are to be connected to the interface (stove rear)
using the connection cable supplied�
(condition as delivered)
External room thermostat
Your stove has an interface on the rear wall to which you can
connect a customary room thermostat� This requires a 2-pole cable
of 0�5 – 0�75 mm2 cross-section that you have to connect instead of
the cable bridge fitted for delivery�
External connection cable bridge
If the control of your stove is to be assumed by an external room
thermostat, you have to connect your external room thermostat (1)
instead of the standard integrated cable bridge (2)�
The connected room thermostat can be operated in either
MANUAL
or
AUTOMATIC MODE.
In both MODES, the current set heat output is
used, in
AUTOMATIC MODE
the heating times set at the stove can also
be activated�
You can see whether the external demand is currently activated in
the INFO main menu in submenu item Info - inputs�
If your stove receives an external demand to stop operation, it takes
approx� 5 minutes until it switches off� All further settings required to
your thermostat can be taken from the respective room thermostat
operating instructions�
Note
Operation is not possible unless either a cable bridge or an external
room thermostat is connected� The external demand has priority
over all operating modes (
MANUAL/AUTOMATIC/COMFORT
)�
Option firenet
Only for combination and pellet stoves with touch panel version
V2�16 or higher�
The firenet module connects your stove to the Internet� You can
operate the stove with any Internet-enabled device (tablet, PC,
Smartphone ���)� So you retrieve the operational status, various
information and make your settings remotely�
For further information, please contact your dealer�