16
7. STATUS DISPLAYS
LED display
Meaning
Action to be taken
The display lamp
flashes intermittently
RED
The stove has just been switched on and the
air flaps start the reference run.
The control system starts a reference run
again after a brief power failure.
The stove cannot heat up until the display
lamp stops flashing.
The display lamp is
constantly
RED
The combustion chamber is cold and the
stove is in neutral.
The combustion chamber temperature has
fallen below the temperature specified for
adding wood.
The stove is ready to heat up.
Optimum control process can no longer
be ensured, adding wood is not permitted.
The stove must be heated up again.
The display lamp is
constantly
GREEN
The stove is in normal operation.
The display lamp is
constantly
YELLOW
The stove is in ECO operation.
The display lamp
flashes regularly
RED
The temperature specified for adding wood
was not reached.
Open the combustion chamber door and
add a log or let the stove go out.
The display lamp
flashes regularly
GREEN
After the opening of the combustion
chamber door, the stove tries to light the
wood added.
The riddle grate should be open during
combustion as well as a lockable damper
clap in the flue pipe (if in use).
The display lamp
flashes regularly
YELLOW
The ECO key was pressed after adding wood.
The magnetic switch sequence was initiated
See “Actions to be taken – flashes
regularly green”
See “Complete closing of the air flaps”