![RIKA LIVO AH Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/rika/livo-ah/livo-ah_operating-manual_1461337020.webp)
20
10. PROBLEMS - POSSIBLE SOLUTIONS
Problem 1
Fire burns with weak, orange flame. Pellets heap up in fire trough,
window soots up.
Cause(s)
Q
Insufficient combustion air
Q
Poor chimney draught
Q
Stove is sooted over inside
Possible solutions
Q
Remove any ash or clinker from the fire trough that may block the
air inlets. If possible swap to better pellet quality
(see CLEANING
AND MAINTENANCE)
Q
Check whether flue gas pipes are blocked with ash
(see CLEANING
AND MAINTENANCE)
.
Q
Check whether the air intake or flue tubes are blocked.
Q
Check door and cleaning cover seals for leaks
(see CLEANING AND
MAINTENANCE)
Q
Clean fan
(see CLEANING AND MAINTENANCE)
Q
Have service performed by authorised specialist company.
Q
The window has to be cleaned from time to time
(see CLEANING
AND MAINTENANCE)
Problem 2
Stove smells strongly and smokes outside.
Cause(s)
Q
Burning-in phase (taking into service)
Q
Stove has accumulated dust and/or dirt
Possible solutions
Q
Wait to end of burning-in phase and ventthe room sufficiently.
Q
Vacuum off any dust deposits from the convection air openings
at regular intervals
Problem 3
Flue gas discharge when wood is added and during heating phase.
Cause(s)
Q
Leaking cleaning openings
Q
Chimney draught too low
Q
Leaking flue pipe connection
Possible solutions
Q
Check seals and replace (fire door, cleaning lid, ..)
Q
Check chimney
Q
Check connections and if necessary re-seal
Note
Please note that checks on the control system and wiring may
only be performed in unit switched dead. Any repairs may only be
performed by trained specialists.
Tip
If a malfunction message occurs, the cause must first be remedied;
the unit can be put back into operation by acknowledging the
malfunction at the internal unit.