background image

10

2. IMPORTANT INFORMATION

General warning and safety information

Observance  of  the  introductory  general  warning  information  is 
imperative.

 

Q

Read the entire manual thoroughly before installing and putting 
the stove into service. Observe the national provisions and laws 
as well as the regulations and rules applicable locally.

 

Q

RIKA stoves should only be installed in rooms with normal humidity 
(dry areas according to VDE 0100 Part 200). The furnaces are not 
splash water protected and may not be installed in wet areas.

 

Q

Only approved transport equipment with sufficient load carrying 
capacity may be used with your heating appliance.

 

Q

Your  heating  appliance  is  not  suitable  for  use  as  a  ladder  or 
stationary scaffolding.

 

Q

The burning of fuel releases heat energy that lead to extensive 
heating of the stove surfaces, doors, door and operating handles, 
glass, flue pipes and possibly the front wall. Refrain from touching 
these parts without appropriate protective clothing or equipment 
e.g.  heat-resistant  gloves  or  means  of  operation  (operating 
handle).

 

Q

Make  your  children  aware  of  this  particular  danger  and  keep 
them away from the stove during heating.

 

Q

Only burn approved heating materials.

 

Q

The combustion or introduction of highly flammable or explosive 
materials  such  as  empty  spray  cans  etc.  in  the  combustion 
chamber  and  storing  them  near  the  stove  is  strictly  prohibited 
due to the danger of explosion.

 

Q

No light or inflammable clothing is to be worn when post-heating.

 

Q

Use the heat-resistant gloves supplied to open the doors of your 
stove.

 

Q

Make  sure  that  no  embers  fall  out  of  the  combustion  chamber 
onto inflammable material.

 

Q

Placing  non-heat  resistant  objects  on  the  stove  or  near  it  is 
prohibited.

 

Q

Do not place clothing on the stove to dry.

 

Q

Laundry racks etc. must be placed at a sufficient distance to the 
stove – ACUTE DANGER OF FIRE!

 

Q

When  your  stove  is  burning,  the  use  of  highly  inflammable  and 
explosive materials in the same or adjacent rooms is prohibited.

 

Q

If  the  stove  is  heated  in  continuous  operation,  the  cleaning 
intervals are shorter. Increased wear, especially of the thermally 
stressed  parts,  is  the  result.  Please  therefore  strictly  follow  the 
requirements for cleaning and maintenance!

Note

Waste and liquids may not be burnt in the stove!

Note

To prevent your stove from overheating of the internal components,
do never cover the convection fins!

Note

 

CAUTION when filling the pellet container. The opening of the pellet 
container  is  sufficiently  dimensioned  to  ensure  easy  filling.  Take 
great care that no pellets drop to the convection fins and the hot 
stove body. This can cause a lot of smoke. 

Tip

Therefore  we  recommend  refilling  the  pellet  container  at  a  cold 
stove.

Note

Your stove will expand and contract during the heating and cooling 
phase.  This  can  sometimes  lead  to  slight  bending  or  cracking 
noises. This is normal and is no reason for a complaint.

First heating

The stove body, just as various steel parts, cast iron parts and the 
flue  pipes  are  painted  with  a  heat  resistant  paint.  During  the  first 
heating the paint dries out completely. This may cause a slight smell. 
Touching or cleaning the painted surfaces during the curing should 
be  avoided.  The  hardening  of  the  paint  is  finished  after  the  first 
heating with high power. 

Safety distances

Note

1. To non-combustible objects
a > 40 cm b > 10 cm
2.  To  combustible  objects  and  reinforced  concrete  load-bearing 
walls 
a > 80 cm b > 20 cm

Tip

please observe a minimum distance of 20 cm behind and sideways 
the stove for maintenance.

Содержание LIVO AH

Страница 1: ...Operating manual LIVO AH LIVO RAO...

Страница 2: ...INFORMATION ON FUEL PELLETS 12 What are pellets 12 Wood pellet specification according to ENplus A1 12 Pellet container refilling during operation 12 Pellet storage 12 4 TECHNOLOGY AND SAFETY FUNCTION...

Страница 3: ...t daily 17 Cleaning the door glass 17 Cleaning painted surfaces 17 9 CLEANING 18 Cleaning the convection air openings 18 Bearings 18 Checking door seal 18 Combustion air intake 18 Cleaning the pellet...

Страница 4: ...part overview exploded diagram 1 2 3 5 6 4 12 10 21 21 19 19 14 18 24 22 23 17 20 20 19 19 11 8 7 13 9 9 15 15 15 6 6 6 40 39 36 42 41 28 28 29 26 25 35 34 33 32 27 30 37 48 53 54 50 45 49 44 43 52 46...

Страница 5: ...5 EN 4 59 76 75 70 89 86 82 81 77 83 84 68 56 69 60 66 63 65 61 61 62 62 64 6 73 75 71 74 78 71 74 85 57 88 87 58 79 80 67 55...

Страница 6: ...95 96 105 102 100 99 98 97 106 103 104 92 90 91 107 108 108 114 116 115 118 117 111 110 109 109 101 113 112 93 125 136 137 138 134 133 132 131 130 129 121 121 120 120 135 124 128 119 127 126 122 122 1...

Страница 7: ...rew 71 N104973 Washer 73 L01446 Lock washer 74 N110747 Hexagonal nut 75 N110461 Double ball catch 76 L01502 Lock washer 77 N111842 Hexagon socket M03x10 78 N111732 Magnetic switch upper part 79 Z35691...

Страница 8: ...Exhaust g s testing Exhaust temperature C testing Chimney draft requirement Pa 3 The owner of small firing systems or the person authorised for the small firing system is to keep the technical docume...

Страница 9: ...mg mN 3 testing Exhaust g s testing Exhaust temperature C testing Chimney draft requirement Pa 3 The owner of small firing systems or the person authorised for the small firing system is to keep the...

Страница 10: ...at resistant objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q W...

Страница 11: ...1 wind break 2 chimney 3 inspection opening For the selection of the connection and to ensure a proper connection between the stove and chimney please read the guide INSTALLING THE STOVE or ask your...

Страница 12: ...ts with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list of monitored fuel...

Страница 13: ...aning cycle The speed of the flue gas fan is increased every hour for a short period to blow ash from the burn pot increasing the operational safety The status indicator CLEAN appears on the display O...

Страница 14: ...nspection and cleaning must be present The flue pipe connection to the chimney has to be air tight Combustion air Every combustion process requires oxygen from the surrounding air This so called combu...

Страница 15: ...onversion work take particular care of your fingers and any panels and stove attachments Select soft bases to prevent scratches to your living space furniture and stove panels Lift the convection fin...

Страница 16: ...med by an external room thermostat you have to connect your external room thermostat 1 instead of the standard integrated cable bridge 2 The connected room thermostat can be operated in either MANUAL...

Страница 17: ...an cleaning cloth or newspaper Empty the ash drawer Empty the ash drawer regularly The ash drawer is simply pulled forward with the combustion chamber door open Cleaning of the burn pot daily Make sur...

Страница 18: ...o never cover the convection fins Bearings annually All built in bearings pellet screw should be checked Clean or replace bearings depending on condition Checking door seal annually The condition of t...

Страница 19: ...remove the outer cleaning lid Vacuum the combustion residues off the flue gas collecting duct especially the area to the convection fan Install the removed parts in reverse order again Note Your stove...

Страница 20: ...EANING AND MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of bu...

Страница 21: ...the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in the pu...

Страница 22: ...tware version Warranty documents Touchdisplay version Door opener Electrical periphery Connection socket earthed GSM modem present Room thermostat present Function checked Check of system components C...

Страница 23: ...and installation manuals valid at the time of purchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be...

Страница 24: ...setting and printing errors reserved 2017 RIKA Innovative Ofentechnik GmbH Z37479_LIVO_AH_RAO_EN 25 07 2017 RIKA Innovative Ofentechnik GmbH M llerviertel 20 4563 Micheldorf AUSTRIA Tel 43 0 7582 686...

Отзывы: