35
EN
34
Loosen the screw of the flame sensor. Remove the flame sensor and the
silicone hose from the pressure pipe as well.
Loosen the marked screw from the stove. This is used to secure the air
deflector below.
Then mount the support plate with 5 screws to the stove.
Couple the silicone hose to the pressure pipe again (1-2cm).
Thread the flame sensor through the oval hole in the support plate and fix the
pressure bracket with the screw.
Mount the flame sensor cover to this support plate. The flame sensor cable
must be routed through the slotted cover to the outside. Then screw on the fan
housing with 3 screws.
Tip
If you install both convection fans, remove now the lower round cover and the
cable channel and fit here the second fan housing.
Mount the cable channel again after screwing the second convection fan.
Insert the wires from flame sensor and fan motor in the cable channel and put
on the lid.
To fix this and to avoid vibrations, twist the two tabs (located diagonally) with
pliers.