PROGRAMMING THE CONTROL 
 

If you intend to operate your stove manually, set it to 
the manual mode by pressing the ENTER button 
until the display no longer reads either “SB” or “TM”.

 
During start-up, the stove will read “ST” on the first 
display line, and “21” on the second display line. 
“ST” stands for start-up and “21” is the remaining 
start-up time in minutes (the time display will 
decrease as the start-up progresses).  
 
During the start-up cycle, only the auger and 
combustion fan operate with the combustion fan 
gradually increasing in speed.  The convection fan 
will turn on at the end of the start-up cycle. 
 

NOTE:  

As long as the stove is running, whether in 

the start-up mode, cleaning cycle, in normal 
operation, or while operating under the timed mode, 
you can increase or decrease the heat output level 
at any time by pressing the 

+

 

or “

“ keys.   

 

If the stove needs to be turned off at any time, push 
the ON/OFF button and the stove will immediately 
begin the shut-down process.  Complete shut-down 
takes a total of eight minutes.  The stove may 
remain hot for several hours after turning off. 
 
If the stove is running in timed mode when the 
power button is pushed, the schedule will resume at 
the next programmed interval. 

Содержание Austroflamm Integra II

Страница 1: ...Page 1 of 9 copyright 2008 Lucky Distributing Inc Revision 3 0 Austroflamm Integra II Visio Premio Pellet Stoves User Control Panel Operating Guide...

Страница 2: ...ge between each of the three different operating modes Manual Mode press the power button to turn the unit on and off Automatic or Timed Mode TM runs according to a schedule that you determine Standby...

Страница 3: ...y pressing ENTER NOTE Start and end times are in military format displays as 0 for midnight through 23 for 11pm The display should now read E1 for the ending time of the first heating period on Monday...

Страница 4: ...y 5 and 300 minutes The frequency of how often the cleaning cycle should run will vary depending upon pellet quality heat output settings availability of outside air and the natural ventilation of you...

Страница 5: ...n operate with the combustion fan gradually increasing in speed The convection fan will turn on at the end of the start up cycle NOTE As long as the stove is running whether in the start up mode clean...

Страница 6: ...Page 6 of 9 copyright 2008 Lucky Distributing Inc Revision 3 0 CONTROL FLOW CHART...

Страница 7: ...stablished schedule MO TU WE TH FR SA SU Weekdays Monday to Sunday S1 S2 E1 E2 Start 1 Start 2 End 1 End 2 Heating start times heating end times for automatic TM mode PS Power Start Output value from...

Страница 8: ...her Fuel Type FU ______ use FU2 for altitude above 2000ft and or direct vent installations this function only available in software v1 33 and higher Cleaning Cycle CL ______ cleaning cycle frequency F...

Страница 9: ...Page 9 of 9 copyright 2008 Lucky Distributing Inc Revision 3 0...

Отзывы: