BASIC OPERATION 

 

DO NOT start your stove until the venting 
installation is complete 
 
NOTE:  

Your pellet stove is exclusively for burning 

pellets made from wood of a controlled quality. 
Non-pelletized solid fuels (straw, corn, chopped 
matter, etc.) should not be used.  Failure to adhere 
to these guidelines will void your warranty. 
 

NOTE:  

When operated correctly, your pellet stove 

will not overheat.  Improper operation can shorten 
the life expectancy of the stove and its components.
 

ATTENTION

: Your stove’s automatic ignition 

system will not work properly if either the hopper lid 
or combustion door are open. 

 
CONTROL UNIT PROGRAMMING AND 
FUNCTION 

Your pellet stove is equipped with a modern 
programmable control board and control software. 
The owner can set all equipment functions via the 
control keypad which is found on the right hand side 
of the unit.  The control board and software should 
only be altered by trained specialists.  Improper or 
unauthorized changes to your stove, unless outlined 
in your owner’s manual or this operating guide, will 
void your warranty. 
 

Possible Operating Modes 

Pressing ENTER on the control panel enables the 
user to change between each of the three different 
operating modes. 
  

  Manual Mode - press the power button to 

turn the unit on and off. 

  Automatic or Timed Mode (TM) - runs 

according to a schedule that you determine. 

  Standby Mode (SB) - waiting for you to 

change to one of the other two modes by 
pressing the “Enter” button on the key-pad. 
No function, other than programming, can 
occur in this mode.   

 

Your RIKA pellet stove is equipped with an electronic ignition start-up system.  Starter fluids or gels are not necessary and 
should never be used.  Simply push the power button and the unit will ignite within a 12-minute period of time.  Total start-up 
cycle time is 21 minutes.

Control Keypad 

 
All settings and functions can be regulated via this 
unit. 

 

 

DISPLAY BOX 

Displays the operating modes in illuminated letters 
and numbers. 
 

MENU

 

Used for navigation in and to the different menu and 
sub-menu levels. 
 

ENTER

 

Used for navigation through the main menus (SB, 
ON, TM) and for confirming user entries. 
 

MINUS & PLUS

 

Used for lowering or increasing heat output levels 
and for changing program values. 
 

POWER  

Used for turning the unit on and off. 
 

TURNING YOUR STOVE ON AND OFF

 

To operate your stove manually, place it into 
manual mode (see the “POSSIBLE OPERATING 
MODES” section).   
 

Once in manual mode, the stove is turned on and off 
by pressing the power button.  Heat output is 
controlled by pressing the “+” and “–“ buttons.

 

Menu 

Minus

Power

Digital Display 

Enter 

Plus 

Содержание Austroflamm Integra II

Страница 1: ...Page 1 of 9 copyright 2008 Lucky Distributing Inc Revision 3 0 Austroflamm Integra II Visio Premio Pellet Stoves User Control Panel Operating Guide...

Страница 2: ...ge between each of the three different operating modes Manual Mode press the power button to turn the unit on and off Automatic or Timed Mode TM runs according to a schedule that you determine Standby...

Страница 3: ...y pressing ENTER NOTE Start and end times are in military format displays as 0 for midnight through 23 for 11pm The display should now read E1 for the ending time of the first heating period on Monday...

Страница 4: ...y 5 and 300 minutes The frequency of how often the cleaning cycle should run will vary depending upon pellet quality heat output settings availability of outside air and the natural ventilation of you...

Страница 5: ...n operate with the combustion fan gradually increasing in speed The convection fan will turn on at the end of the start up cycle NOTE As long as the stove is running whether in the start up mode clean...

Страница 6: ...Page 6 of 9 copyright 2008 Lucky Distributing Inc Revision 3 0 CONTROL FLOW CHART...

Страница 7: ...stablished schedule MO TU WE TH FR SA SU Weekdays Monday to Sunday S1 S2 E1 E2 Start 1 Start 2 End 1 End 2 Heating start times heating end times for automatic TM mode PS Power Start Output value from...

Страница 8: ...her Fuel Type FU ______ use FU2 for altitude above 2000ft and or direct vent installations this function only available in software v1 33 and higher Cleaning Cycle CL ______ cleaning cycle frequency F...

Страница 9: ...Page 9 of 9 copyright 2008 Lucky Distributing Inc Revision 3 0...

Отзывы: