RIKA Ambia Скачать руководство пользователя страница 16

16

5. BRIEF INFORMATION ON COMBUSTIBLE - LOGS

Suitable fuels and fuel amounts

Your stove is generally suitable for burning dry firewood� You can 
also burn combustibles such as wood briquettes�

Note

A stove is not a waste incinerator� The warranty lapses if waste or 
non-approved materials such as plastic, treated wood (chipboard), 
coals or clothes are burnt! This leads to damage to the stove and 
chimney and to environmental pollution!

Note

FUEL AMOUNTS
The stove is fitted with a construction-specific flat firebox� This 
means only one layer of logs may be laid on the base embers�
Please observe that adding greater quantities of logs leads to 
emission of high temperatures, higher than the stove is designed 
for� This may cause damage to your stove� This is reflected in 
particular on the glass of the combustion chamber door, which will 
get a gray haze in case of overheating the stove, which can not be 
removed�

Wood types

Different types of wood have different calorific values� Wood from 
deciduous trees is particularly suitable� It burns with a constant 
flame and forms long-lasting embers� Coniferous wood has higher 
levels of resin and burns off faster as do all softwoods and tends to 
spray sparks�

Wood type

Calorific 

value

kWh/m

3

Calorific 

value

kWh/kg

Maple

1900

4,1

Birch

1900

4,3

Beech

2100

4,2

Oak

2100

4,2

Alder

1500

4,1

Ash

2100

4,2

Spruce

1700

4,4

Larch

1700

4,4

Poplar

1200

4,1

Robinia

2100

4,1

Fir

1400

4,5

Elm

1900

4,1

Willow

1400

4,1

Output controlling

The output of your stove is regulated manually or via the Rikatronic-
control� Please observe that the output of your stove also depends 
on the chimney draught and the amount of fuel added�

Clean combustion

1.  The firewood must be dry and untreated.

The should-be value is between 14 % and 18 % relative wood moisture�

Wood has to be stored dry and ventilated for 2–3 years�

2.  Correct firewood amount and size:

 

Q

Too much firewood leads to overheating� This can damage your 
stove and increases the exhaust emission values�

 

Q

If you take too little firewood or if the logs you place are too large 
the stove will not reach the optimum operating temperature� The 
flue gas values also increase in this case�

 

Q

For right quantity of firewood see 

AMOUNT OF FUEL�

Содержание Ambia

Страница 1: ...AMBIA Operating manual...

Страница 2: ...safety information 14 First heating 14 Safety distances 14 Prior to set up 15 5 BRIEF INFORMATION ON COMBUSTIBLE LOGS 16 Suitable fuels and fuel amounts 16 Wood types 16 Output controlling 16 Clean co...

Страница 3: ...3 2 EN 1 EXPLANATIONS TO SYMBOLS Important Note Useful Tip Manually Fragile...

Страница 4: ...xploded diagram 5 10 12 11 13 7 3 2 1 7 4 4 4 4 4 6 6 7 7 20 20 21 21 23 22 22 18 19 8 9 9 14 15 16 17 39 40 39 37 36 31 25 33 24 24 26 26 32 32 26 41 32 32 42 43 43 42 25 33 24 24 26 30 29 28 27 30 2...

Страница 5: ...69 50 55 54 54 61 64 64 65 63 59 59 58 58 60 56 56 66 62 67 57 52 72 71 70 53 53 68 51 91 90 93 81 84 84 80 83 83 82 82 92 85 85 87 88 89 86 86 84 84 82 82 5 4 EN...

Страница 6: ...Steel casing 109 110 111 116 104 101 102 103 105 105 112 106 113 114 114 100 107...

Страница 7: ...sing 131 126 130 135 136 137 124 119 119 138 138 137 129 119 139 131 131 127 130 130 135 135 135 136 136 136 137 137 137 132 129 117 124 123 123 118 118 119 119 119 119 119 127 126 128 121 125 133 134...

Страница 8: ...Stone or concrete casing 171 170 172 161 162 169 165 166 163 166 160 164 164 173 175 168 174 174 167...

Страница 9: ...ete casing 182 183 178 187 186 180 184 184 185 185 189 189 189 189 189 176 177 181 179 191 177 195 192 193 194 180 188 188 190 190 194 187 189 189 190 191 191 176 195 195 192 192 193 193 194 194 178 1...

Страница 10: ...on 58 Z37825 Firebrick lining lateral 59 Z37824 Firebrick lining rear 60 Z37861 Firebrick lining rear middle 61 N112274 Hexagonal nut M05 62 Z37827 Firebrick lining cover left 63 Z37823 Firebrick lini...

Страница 11: ...37750 Side panel white stone bottom Z37791 Side panel concrete bottom 165 B18581 Side casing steel left 166 Z37755 Side panel soap stone top Z37756 Side panel white stone top Z37794 Side panel concret...

Страница 12: ...temperature C testing Chimney draft requirement Pa 12 The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to submit it...

Страница 13: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Страница 14: ...en post heating Q Use the heat resistant gloves supplied to open the doors of your stove Q Only use suitable tools from our range of accessories when handling embers and make sure that no embers fall...

Страница 15: ...rated with the combustion chamber door closed Q The combustion chamber door may only be opened to add fuel and must then be closed again otherwise other firing installations connected to the chimney m...

Страница 16: ...icularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all softwoods and tends to spray sparks Wood type C...

Страница 17: ...humidity of your firewood Ideally one rib is enough to light up the fire Tip You can order the RIKA firelighter with the number E15834 at your RIKA dealer Combustion air regulation The performance of...

Страница 18: ...later depending on draught fuel quality and amount Refilling Note Use the handle Cold Hands or the RIKA heat resistant glove for every further addition of wood After the first burn off add one or two...

Страница 19: ...ISK In a cold state dispose it of in the household waste Clean combustion chamber Note Only when the stove is cold You could vacuum out embers FIRE RISK The combustion chamber must be regularly cleane...

Страница 20: ...Clean flue gas outlet annually Remove the flue pipes Inspect and clean the chimney connection Brush off any soot and dust deposits in the stove and in the flue pipes and vacuum 1 2...

Страница 21: ...formance of the stove and pose a safety risk Check seals annually Check the condition of the seals at least once a year Repair or replace seals depending on condition Note Only intact seals ensure you...

Страница 22: ...ss cleaner Problem 2 Stove smells strongly and or fumes are emitted Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solution s Q Wait to end of burning...

Страница 23: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Страница 24: ...only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z38218_AMBIA_EN 6 10 2021 RIKA Innovative Ofentechnik GmbH M llervie...

Отзывы: