Prior to set up

Floor bearing capacity

Ensure that the substructure is capable of bearing the weight of the 
stove prior to set-up�

Note

No modifications may be made to the firing installation� This also 
leads to loss of warranty and guarantee�

Floor protection

A glass, sheet steel or ceramic plate is required, if the floor is 
combustible (wood, carpet, etc�)�

Flue pipe connection

 

Q

Flue pipes pose a particular source of hazard regarding gas leaks 
and fire� Get the advice of an authorised specialist company for 
the layout and assembly�

 

Q

Please observe the corresponding installation guidelines for walls 
panelled with wood when connecting your flue pipes to the stove�

 

Q

Observe the formation of flue gas (atmospheric inversion) and 
draughts when the weather is unfavourable�

 

Q

Infeed of too little combustion air can lead to smoke in the rooms 
or to flue gas leaks� Hazardous deposits in the stove and chimney 
may also occur�

 

Q

If flue gas escapes, let the fire burn out and check whether all the 
air inlet openings are free and the flue gas pipes and the stove 
pipe are clean� If in doubt notify the master chimney sweep since 
draught malfunctions may be connected to your chimney�

Stoves type 1 (BA 1):

 

Q

Suitable for multiple occupancy� (Note the different country 
regulations�) 

 

Q

These may only be operated with the combustion chamber door 
closed�

 

Q

The combustion chamber door may only be opened to add fuel 
and must then be closed again otherwise other firing installations 
connected to the chimney may be endangered�

 

Q

The combustion chamber door is to be kept closed when the 
stove is not in operation�

 

Q

Fouling of the chimney i�e� deposits of highly inflammable 
materials such as soot and tar and subsequently fire in the 
chimney may occur if wet fuel is used and operation is damped 
too much�

 

Q

If this occurs, close the fresh air support (slider, 
regulator, flaps - depending on model)! Disconnect 
the mains plug at the stoves type Rikatronic� 
Phone the fire brigade and get yourself and other residents out 
of harm’s way�

Note

on ROOM-AIR DEPENDENT and ROOM-AIR INDEPENDENT 
OPERATION:

Your stove has been tested as a room-air independent stove 
according to EN 13240 and can be installed as well room-air 
dependent and independent�

When installed room-air dependent in combination with room-
air installations (e�g� controlled ventilation and venting systems 
(extractors etc�) it must be ensured that the stove and the room 
air system are monitored and safeguarded mutually (e�g� via a 
differential pressure controller etc�)� The combustion air infeed of 
approx� 20 m3/h must be ensured� 

Please observe the respective local regulations and rules in 
consultation with your master chimney sweep� For changes after 
the printing of this manual, we can not assume any liability� We 
reserve the right to change without notice�

Содержание Ambia

Страница 1: ...AMBIA Operating manual...

Страница 2: ...safety information 14 First heating 14 Safety distances 14 Prior to set up 15 5 BRIEF INFORMATION ON COMBUSTIBLE LOGS 16 Suitable fuels and fuel amounts 16 Wood types 16 Output controlling 16 Clean co...

Страница 3: ...3 2 EN 1 EXPLANATIONS TO SYMBOLS Important Note Useful Tip Manually Fragile...

Страница 4: ...xploded diagram 5 10 12 11 13 7 3 2 1 7 4 4 4 4 4 6 6 7 7 20 20 21 21 23 22 22 18 19 8 9 9 14 15 16 17 39 40 39 37 36 31 25 33 24 24 26 26 32 32 26 41 32 32 42 43 43 42 25 33 24 24 26 30 29 28 27 30 2...

Страница 5: ...69 50 55 54 54 61 64 64 65 63 59 59 58 58 60 56 56 66 62 67 57 52 72 71 70 53 53 68 51 91 90 93 81 84 84 80 83 83 82 82 92 85 85 87 88 89 86 86 84 84 82 82 5 4 EN...

Страница 6: ...Steel casing 109 110 111 116 104 101 102 103 105 105 112 106 113 114 114 100 107...

Страница 7: ...sing 131 126 130 135 136 137 124 119 119 138 138 137 129 119 139 131 131 127 130 130 135 135 135 136 136 136 137 137 137 132 129 117 124 123 123 118 118 119 119 119 119 119 127 126 128 121 125 133 134...

Страница 8: ...Stone or concrete casing 171 170 172 161 162 169 165 166 163 166 160 164 164 173 175 168 174 174 167...

Страница 9: ...ete casing 182 183 178 187 186 180 184 184 185 185 189 189 189 189 189 176 177 181 179 191 177 195 192 193 194 180 188 188 190 190 194 187 189 189 190 191 191 176 195 195 192 192 193 193 194 194 178 1...

Страница 10: ...on 58 Z37825 Firebrick lining lateral 59 Z37824 Firebrick lining rear 60 Z37861 Firebrick lining rear middle 61 N112274 Hexagonal nut M05 62 Z37827 Firebrick lining cover left 63 Z37823 Firebrick lini...

Страница 11: ...37750 Side panel white stone bottom Z37791 Side panel concrete bottom 165 B18581 Side casing steel left 166 Z37755 Side panel soap stone top Z37756 Side panel white stone top Z37794 Side panel concret...

Страница 12: ...temperature C testing Chimney draft requirement Pa 12 The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to submit it...

Страница 13: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Страница 14: ...en post heating Q Use the heat resistant gloves supplied to open the doors of your stove Q Only use suitable tools from our range of accessories when handling embers and make sure that no embers fall...

Страница 15: ...rated with the combustion chamber door closed Q The combustion chamber door may only be opened to add fuel and must then be closed again otherwise other firing installations connected to the chimney m...

Страница 16: ...icularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all softwoods and tends to spray sparks Wood type C...

Страница 17: ...humidity of your firewood Ideally one rib is enough to light up the fire Tip You can order the RIKA firelighter with the number E15834 at your RIKA dealer Combustion air regulation The performance of...

Страница 18: ...later depending on draught fuel quality and amount Refilling Note Use the handle Cold Hands or the RIKA heat resistant glove for every further addition of wood After the first burn off add one or two...

Страница 19: ...ISK In a cold state dispose it of in the household waste Clean combustion chamber Note Only when the stove is cold You could vacuum out embers FIRE RISK The combustion chamber must be regularly cleane...

Страница 20: ...Clean flue gas outlet annually Remove the flue pipes Inspect and clean the chimney connection Brush off any soot and dust deposits in the stove and in the flue pipes and vacuum 1 2...

Страница 21: ...formance of the stove and pose a safety risk Check seals annually Check the condition of the seals at least once a year Repair or replace seals depending on condition Note Only intact seals ensure you...

Страница 22: ...ss cleaner Problem 2 Stove smells strongly and or fumes are emitted Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solution s Q Wait to end of burning...

Страница 23: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Страница 24: ...only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z38218_AMBIA_EN 6 10 2021 RIKA Innovative Ofentechnik GmbH M llervie...