Table 2 Option (for high-frequency compensation adjustment)
Item# Name
Part No.
1
50 Ω feedthrough adaptor
RP5600A-0300101
High-frequency compensation
Low-frequency compensation must be performed before executing
High-frequency compensation.
Follow the steps below to make high-frequency compensation:
1
.
Connect the 50 Ω feedthrough adaptor (option) to a generator
with fast edge signal.
2
.
Connect the BNC adapter to the 50 Ω feedthrough adaptor.
3
.
Remove the accessories (the spring ground or the hook tip) at
the probe head and the barrel insulator.
4
.
Connect the probe head to the BNC adapter (so as to connect it
to the generator with fast edge signal) and connect the probe to
Low-frequency
Compensation Adjustment
Over compensated
Perfectly compensated