Rigol PVA7000 Series Скачать руководство пользователя страница 2

RIGOL 

User Guide for PVA7000 Series Active Probe 

Guaranty and Declaration 

Copyright

 

© 

2020 

RIGOL

 TECHNOLOGIES CO., LTD. All Rights Reserved. 

 

Trademark Information 

RIGOL

®

 is the trademark of 

RIGOL

.

 

 

Publication Number 

UGE31101-1110 
 

Notices 

 

RIGOL

 products are covered by P.R.C. and foreign patents, issued and 

pending. 

 

RIGOL

 reserves the right to modify or change parts of or all the 

specifications and pricing policies at the compan

y’s sole decision.

 

 

Information in this publication replaces all previously released materials. 

 

Information in this publication is subject to change without notice. 

 

RIGOL 

shall not be liable for either incidental or consequential losses in 

connection with the furnishing, use, or performance of this manual, as well 
as any information contained. 

 

Any part of this document is forbidden to be copied, photocopied, or 

rearranged without prior written approval of 

RIGOL

.   

 

Product Certification 

RIGOL

 guarantees that this product conforms to the national and industrial 

standards in China as well as the ISO9001:2015 standard and the 
ISO14001:2015 standard. Other international standard conformance 

certifications are in progress. 
 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание PVA7000 Series

Страница 1: ...User Guide PVA7000 Series Active Probe May 2020 RIGOL TECHNOLOGIES CO LTD www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 2: ...erials Information in this publication is subject to change without notice RIGOL shall not be liable for either incidental or consequential losses in connection with the furnishing use or performance of this manual as well as any information contained Any part of this document is forbidden to be copied photocopied or rearranged without prior written approval of RIGOL Product Certification RIGOL gu...

Страница 3: ...ms on the Product DANGER It calls attention to an operation if not correctly performed could result in injury or hazard immediately WARNING It calls attention to an operation if not correctly performed could result in potential injury or hazard CAUTION It calls attention to an operation if not correctly performed could result in damage to the product or other devices connected to the product Safet...

Страница 4: ...h PVA7250 2 5GHz Main topics PVA7000 Series Overview This chapter gives a brief introduction of the probe including general inspection probe dimensions standard accessories and etc To Use PVA7000 Series Active Probe This chapter introduces how to use the probe including how to connect to the oscilloscope how to use the probe head how to replace probe accessories how to adjust the offset voltage ho...

Страница 5: ...on 3 Probe Dimensions 4 Accessories and Options 5 Active Probe Amplifier 5 Probe Head 6 To Use PVA7000 Series Active Probe 9 To Connect to the Oscilloscope 10 To Use the Probe Head 12 To Replace Probe Accessories 15 To Adjust Offset Voltage 16 To Calibrate the Probe 17 Care and Cleaning 18 Warranty 19 Specifications 20 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply...

Страница 6: ...ter guides users to quickly get familiar with the PVA7000 series active probe Main topics Probe Introduction General Inspection Probe Dimensions Accessories and Options Active Probe Amplifier Probe Head www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 7: ... tip prolongs the service life of the probe and the probe tip spacing can be precisely adjusted to fit different test point spacings PVA7000 is compatible with the auto identification port of RIGOL MSO DS7000 MSO8000 series oscilloscope and can be recognized and configured automatically by this port Its snap in BNC connector enables easier connection with the oscilloscope PVA7000 provides various ...

Страница 8: ... be liable for the damage to the instrument resulting from shipment RIGOL would not be responsible for free maintenance rework or replacement of the instrument 2 Inspect the instrument In case of any mechanical damage missing parts or failure in passing the electrical and mechanical tests contact 3 Check the accessories Please check the accessories according to the packing lists If the accessories...

Страница 9: ...000 Series Active Probe Probe Dimensions Figure 1 shows the dimensions of the main parts of PVA7000 series active probe Figure 1 Probe Dimensions www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 10: ...ier 1 Solder in Differential Probe Head 1 Solder in Single ended Probe Head 1 Hand held Differential Probe Head 1 0 2mm Nickel Wire 1 Trim Gauge 1 50Ω Probe Tip 8 Marker Rings Yellow Pink Light Blue Dark Blue 8 User Guide 1 Probe Bag 1 Storage Box 1 Note The accessories listed in this section are only for reference the actual product is the standard Active Probe Amplifier The active probe amplifie...

Страница 11: ...tention to their polarities If the polarity is reversed the performance of the active probe would be undermined and the active probe might even be damaged CAUTION There are black mark sleeve on the negative pole of the solder in single ended probe head Probe Head PVA7000 supports hand held probe head and solder in probe head 1 Hand held Probe Head Pos Neg Marker www GlobalTestSupply com Find Quali...

Страница 12: ...erential probe head the spacing between the probe tips is controlled by the roller on the probe head As shown in Figure 3 turning the roller forwards or backwards can precisely adjust the spacing between the two probe tips Figure 3 Hand held Differential Probe Head As shown in Figure 4 the probe tip is a standard accessory and replaceable If it is damaged during use you can easily replace it with ...

Страница 13: ...lder in probe head for measurement please use an auxiliary device to fix the probe head Do not use your hand to fix the probe head or else the lead resistor soldered onto the probe head might break or fall off What s more the hand held position might also affect the probe performance The nickel wire of the solder in probe head is a standard accessory If the nickel wire under use is damaged or brok...

Страница 14: ...ervice life of the probe and ensure the effectiveness of the signal measurement result This chapter introduces in detail the using method of the PVA7000 series active probe Main Topics To Connect to the Oscilloscope To Use the Probe Head To Replace Probe Accessories To Adjust Offset Voltage To Calibrate the Probe www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 15: ...f the oscilloscope Please connect the probe to the oscilloscope following the steps below 1 Connect the probe head in the figure taking a hand held differential probe head for example with the active probe amplifier If a single ended probe head is used during the connection pay attention to their polarities 2 Connect the other end of the active probe amplifier to the channel input connector of the...

Страница 16: ...own in the left figure below pull the connector straight out of the oscilloscope as shown in the right figure below and then release the button CAUTION Do not twist the probe on the BNC connector of the oscilloscope Otherwise the probe might be damaged www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 17: ...han 2 5 GHz The spacing between the two probe tips can be precisely adjusted by turning the roller The probe tips are replaceable which can prolong the service life of the probe The hand held differential probe head can be used to measure differential and single ended signals During the measurement you can turn the roller on the probe head to adjust the spacing between the probe tips so as to fit ...

Страница 18: ...f the nickel wire enhances the usability of the probe and prolongs its service life The structure of the solder in differential probe head is shown in Figure 8 Figure 8 Solder in Differential Probe Head Solder in differential probe head 0 2mm Nickel Wire When the points to be tested are widely spaced the length of the nickel wire will be increased At this point overshoot and ringing will occurs an...

Страница 19: ...der in single ended probe head is shown in Figure 9 The pin at the same side with the negative pole mark sleeve refer to Figure 6 is negative Figure 9 Solder in Single ended Probe Head Solder in single ended probe head 0 2mm Nickel Wire When the points to be tested are widely spaced the length of the nickel wire will be increased At this point overshoot and ringing will occur and the high frequenc...

Страница 20: ...he probe tip and probe head are connected with screw thread so please note the screw rotation and strength when removing and installing the probe tip 3 To replace the nickel wire If the nickel wire of the solder in probe head under use becomes damaged or breaks off you can replace a new one The probe head nickel wire should satisfy the following size requirement that is the length must be shorter ...

Страница 21: ...You can adjust the offset voltage by operating the front panel menu of the oscilloscope The operation method is as shown below 1 Follow the instructions in To Connect to the Oscilloscope to connect the PVA7000 series active probe to the channel input terminal e g CH1 of the MSO DS7000 MSO8000 oscilloscope 2 Open the probe offset voltage control menu of the MSO DS7000 MSO8000 oscilloscope front pan...

Страница 22: ...e calibration will last for about 40 to 50 seconds When the probe calibration is finished a prompt message Probe calibration finished or Probe calibration failure is displayed in the user interface of the oscilloscope Note Technical specifications of the PVA7000 series active probe depend on the calibration operation After the calibration is finished the DC gain offset voltage zero and offset gain...

Страница 23: ...be and its accessories regularly according to their operation conditions using the method below 1 Disconnect the probe from the oscilloscope or power source 2 Clean the external surfaces of the probe and its accessories with a soft cloth dampened with mild detergent or water WARNING To avoid short circuit resulting from moisture or even personal injuries ensure that the probe is completely dry bef...

Страница 24: ...antees free replacement or repair for the defective product There is no other warranty expressed or implied except such as is expressly set forth herein or other applicable warranty card There is no implied warranty of merchantability or fitness for a particular purpose Under no circumstances shall RIGOL be liable for any consequential indirect ensuing or special damages for any breach of warranty...

Страница 25: ... mode Range 6 25V DC to 100Hz 1 25V 100Hz Common Mode Rejection Ratio 45dB 1MHz DC Attenuation 10 1 2 Zero Offset Error 1 30mV before calibration 5mV after calibration Offset Voltage Range 2V Offset Accuracy 1 3 of current range before calibration 1 of current range after calibration Input Noise 3 8mVpp Propagation Delay 7ns Max Input Voltage 30V Peak CAT I 2 Electrostatic Protection HBM 8kV www G...

Страница 26: ...llation Category Overvoltage Category I signal level special equipment or parts of equipment telecommunication electronic etc with smaller transient voltages than installation category Overvoltage Category II Installation Category Overvoltage Category II local level appliance portable equipment etc with smaller transient voltages than installation category Overvoltage Category III 3 The weight of ...