Chapter 2 Basic Waveform Output
User’s Guide for DG5000
2-8
Leading/Trailing Edge Time
The Leading (rising) edge time is defined as the duration of the pulse amplitude rising
from 10% to 90% threshold, while the Trailing (falling) edge time is defined as the
duration of the pulse amplitude moving down from 90% to 10% threshold.
Press Pulse
Leading (or Trailing ) to highlight the softkey, and then use the
numeric keyboard to input “50” and select the unit “ns” in the pop-up menu.
Edge Time range: 2.5 ns to 1 ms.
Selectable Leading/Trailing Edge Time units: sec, msec, μsec, nsec.
You can also use the knob to modify this parameter.
Delay
Delay is defined as the delayed time of the output of a channel relative to the output
of the other channel.
Delay
CH1 Output
CH2 Output
Note: The delay function is only for dual-channel models.
Press Pulse
Delay to highlight the softkey, and then use the numeric keyboard to
input “8” and select the unit “μs” in the pop-up menu.
Delay Time range: 0 s to pulse period
Selectable Delay Time units: sec, msec, μsec, nsec.
You can also use the knob to modify this parameter.
www.
.com
1.800.561.8187
Содержание DG5071
Страница 2: ...www com information itm com 1 800 561 8187...
Страница 46: ...www com information itm com 1 800 561 8187...
Страница 78: ...www com information itm com 1 800 561 8187...
Страница 114: ...www com information itm com 1 800 561 8187...
Страница 126: ...www com information itm com 1 800 561 8187...
Страница 134: ...www com information itm com 1 800 561 8187...
Страница 200: ...www com information itm com 1 800 561 8187...
Страница 206: ...RIGOL Chapter 11 Remote Control User s Guide for DG5000 11 6 www com information itm com 1 800 561 8187...
Страница 210: ...www com information itm com 1 800 561 8187...
Страница 220: ...www com information itm com 1 800 561 8187...