Performing a Quality Control Test
CLOSE
9
Recalling Test Result and Average
®
9. Tightly replace the cap on the
Rightest
Control Solution bottle.
10. The Control Solution result appears. Compare your Quality Control Test result to the Control Solution
®
Range printed on the
Rightest
Blood Glucose Test Strip vial label.
GS250S
PRECAUTION
- Your Control Solution results will not be calculated for an average reading but still can be recalled. The Control
Solution Test result will be shown with " " symbol on the screen.
- Our suggestion environment for Control Solution Test is 59-104
℉
(15-40
℃
).
®
- Before " " and " " appears, please don't touch the
Rightest
Control Solution to the sample entry on strip
®
because the
Rightest
Blood Glucose Meter is still in an internal check. If you do so, the meter will
show " " and " ". Accompanied by beeps (if volume is turned on).
®
- Don't drip the
Rightest
Control Solution to sample entry of the strip directly.
®
The reagent on strip might be sucked into the bottle of
Rightest
Control Solution and might cause
®
the degeneration of
Rightest
Control Solution. Doing this might contaminate the meter via the test
strip port as well.
®
- Don't touch the tip of the
Rightest
Control Solution bottle. If you have touched it, please clean up with water.
GM250S
2.
To finish reviewing memory tests, press Main button again, and you will enter the Average screen. By pressing the Right
button, the display shows "AVG" on the upper right corner of the display and the average value for the actual day. By
sequentially pressing the Right or Left button you will get to the 1-day, 14-day, 30-day and 90-day average of your
blood glucose values. You will see the number of the calculated days on the lower left corner and the number of the
calculated readings on the lower right corner.
1. Press the Main button to switch from the Time mode to the Memory mode.
First you will see the
”MEM” symbol on the up per left corner of the display. When you press the right button, the latest
result will be displayed. By pressing the right button sequentially former test results will be shown in
historical order. You will see the sequence number on the lower right corner and the year on the lower
left corner of the display followed by date and time of the measurement.
Note: The Right button is for reviewing the tests with sequence number increasing, and the Left button is for reviewing
tests with sequence number decreasing. The sequence no “1” is the latest result while sequence no “500” is the oldest
test result.
The
Blood Glucose Meter is able to store 500 test results with time and date automatically. If your meter
has stored 500 results, which is the maximum memory of the meter, the newest test result will replace the oldest one. To
recall your test memory, start the meter without test strip inserted.
®