![Right Weigh 201-RTS Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/right-weigh/201-rts-series/201-rts-series_installation-and-operation-manual_1460690013.webp)
13
Calibration
Once both empty and loaded calibration has been performed, the scale is ready
to use! If you have any trouble entering calibration data, refer to the
troubleshooting section of this manual.
2.
Loaded Calibration Point
1: While the vehicle is fully loaded, obtain a weight from a certified in
-
ground
scale for the axle group(s) attached to the Right Weigh load scale.
2: Park on a level surface. Shift the transmission to neutral and set the parking
brakes. Chock the wheels to prevent unexpected vehicle movement, then
release the parking and service brakes.
3: Make sure the Height Control Valve (HCV) has fully inflated the air bags. If
needed, briefly dump the air from the suspension and allow the HCV to refill
the system. (This may take several minutes depending on the type of HCV.)
4: Press the ON/OFF button to turn on the Right Weigh load
scale.
5: Press the MENU button to switch the display to the axle
group you wish to calibrate. Press and hold the C HIGH button
until the
“
C/H
”
symbol appears.
6: Adjust the value using the UP and DOWN arrows so that it
matches your scale ticket for the axle group.
7: To save, press and hold the C HIGH button until the
“
C/H
”
symbol disappears.
8: Repeat steps 5
-
7 for each remaining axle group.
Содержание 201-RTS Series
Страница 17: ...17 Notes...